84
IBM : Hardware Maintenance Manual
Diagnostic Error Code
025-198-XXX
IDE interface test aborted
025-199-XXX
IDE interface test failed, cause unknown
030-000-XXX
SCSI interface Test Passed
030-00X-XXX
030-01X-XXX
SCSI interface failure
030-027-XXX
SCSI interface Configuration/Setup error
030-03X-XXX
030-04X-XXX
SCSI interface error
030-195-XXX
SCSI interface Test aborted by user
030-196-XXX
SCSI interface test halt, error threshold
exceeded
030-197-XXX
SCSI interface test warning
030-198-XXX
SCSI interface test aborted
FRU/Action
1.
If a component is called out, make sure it
is connected and/or enabled
2.
Flash the system and re-test
3.
Go to the "Undetermined problems"
section
1.
Go to the "Undetermined problems"
section
2.
Flash the system and re-test
3.
Replace component under function test
1.
No action
1.
SCSI signal cable
2.
Check power supply
3.
SCSI device
4.
SCSI adapter card, if installed
5.
System board
1.
SCSI signal cable
2.
Flash the system
3.
SCSI device
4.
SCSI adapter card, if installed
5.
System board
1.
SCSI signal cable
2.
Check power supply
3.
SCSI device
4.
SCSI adapter card, if installed
5.
installed
System board
1.
Information
2.
Re-start the test, if necessary
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
1.
Make sure the component that is called
out is connected and/or enabled
2.
Re-run test
3.
Component that is called out in warning
statement
4.
Component under test
1.
If a component is called out, make sure it
is connected and/or enabled
2.
Flash the system and re-test
3.
Go to the "Undetermined problems"
section

Hide quick links: