IBM 2254 Hardware Maintenance Manual page 84

Computers
Hide thumbs Also See for 2254:
Table of Contents

Advertisement

76
IBM : Hardware Maintenance Manual
Diagnostic Error Code
001-040-XXX
System IRQ failure
001-041-XXX
System DMA failure
001-195-XXX
System Test aborted by user
001-196-XXX
System test halt, error threshold exceeded
001-197-XXX
System test warning
001-198-XXX
System test aborted
001-199-XXX
System test failed, cause unknown
001-250-XXX
System ECC error
001-254-XXX
001-255-XXX
001-256-XXX
001-257-XXX
System DMA error
001-260-XXX
001-264-XXX
System IRQ error
001-268-XXX
System IRQ1 failure
001-269-XXX
System IRQ2 failure
001-270-XXX
System IRQ3 failure
001-271-XXX
System IRQ4 failure
001-272-XXX
System IRQ5 failure
001-273-XXX
System IRQ6
(diskette drive) failure
001-274-XXX
System IRQ7 failure
FRU/Action
1.
Power-off/on system and re-test
2.
System board
1.
Power-off/on system and re-test
2.
System board
1.
Information
2.
Re-start the test, if necessary
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
1.
Make sure the component that is called
out is connected and/or enabled
2.
Re-run test
3.
Component that is called out in warning
statement
4.
Component under test
1.
If a component is called out, make sure it
is connected and/or enabled
2.
Flash the system and re-test
3.
Go to the "Undetermined problems"
section
1.
Go to the "Undetermined problems"
section
2.
Flash the system and re-test
3.
Replace component under function test
1.
System board
1.
System board
1.
System board
1.
Device on IRQ1
2.
System board
1.
Device on IRQ2
2.
System board
1.
Device on IRQ3
2.
System board
1.
Device on IRQ4
2.
System board
1.
Device on IRQ5
2.
System board
1.
Diskette Cable
2.
Diskette drive
3.
System board
1.
Device on IRQ7
2.
System board

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

225663366337633963416342 ... Show all

Table of Contents