102
IBM : Hardware Maintenance Manual
POST Error Code
10464
Hard Drive read error
10467
Drive non-fatal seek error
10468
Drive fatal seek error
10469
Drive soft error count exceeded
10470, 10471, 10472
Controller wrap error
10473
Corrupt data. Low level format might be
required
10480
10481
ESDI drive D seek error
10482
Drive select acknowledgement bad
106X1
10635
10651, 10660
106XX
Not listed above
107XX
109XX
Check the adapter cables
112XX
This adapter does not have cache
119XX
121XX
FRU/Action
1.
Run Enhanced Diagnostics
1.
Run Enhanced Diagnostics
1.
Run Enhanced Diagnostics
1.
Run Enhanced Diagnostics
1.
Run Enhanced Diagnostics
Information only
1.
Hard Disk Drive (ESDI)
2.
Drive Cable
3.
System Board
1.
Run Enhanced Diagnostics
1.
Run Enhanced Diagnostics
1.
Check Configuration
2.
Ethernet Adapter
1.
Power-off computer, wait ten seconds
then power-on the computer
2.
Ethernet Adapter
1.
Check Cables
2.
Ethernet Adapter
1.
Ethernet Adapter
1.
5.25-inch External
Diskette Drive
2.
5.25-inch Diskette
Drive Adapter/A
1.
ActionMedia
Adapter/A
2.
System Board
3.
Riser card
1.
SCSI Adapter
2.
Any SCSI Device
3.
System Board
4.
Riser card
1.
3119 Adapter
1.
Modem Adapter
2.
Any Serial Device
3.
System Board
4.
Riser card