CG30-40 (GAS/STEAM )
ELECTRICAL SERVICE SPECIFICATIONS
IMPORTANT:
208 VAC and 230/240 VAC ARE NOT THE SAME. When
ordering, specify exact voltage.
NOTES:
A.
Circuit breakers are thermal/magnetic (industrial) motor curve type
ONLY. For others, calculate/verify correct breaker size according
to appliance amp draw rating and type of breaker to be used.
Circuit breakers for 3-Phase (3ø) dryers must be 3-pole type.
B.
SERVICE
VOLTAGE
120
208
240
208
240
380-400
416
460/480
* IMPORTANT:
50HZ versions of the 380,400,416 volt machines are manufactured 4 wire ONLY (unless ordered
special as 3 wire service).
IMPORTANT: Figures shown are for non-reversing models only. For reversing models contact
Continental Girbau, Inc.
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is
affixed to the upper left side panel area behind the top control (access) door. In the
case of 208 VAC or 230/240 VAC, the supply voltage must match the electric service
specifications of the data label exactly.
IMPORTANT: The wire size must be properly sized to handle the related current.
WARNING: 208 VAC AND 230/240 VAC ARE NOT THE SAME. Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: The manufacturer reserves the right to make changes in specifications at any time without
notice or obligation.
WIRE
PHASE
SERVICE
2
2
2
3/4
3/4
3/4*
3/4*
3/4
®
APPROX.
AMP DRAW
60 Hz
50 Hz
9.6
-
6
-
5.3
4.4
2.9
-
3.2
3.5
-
2.2
-
2.3
2.1
-
26
(PER DRYER)
CIRCUIT
BREAKER
AMPERAGE
15
15
15
15
15
15
15
15