CAPACITIES AND SPECIFICATIONS

APU
Engine . . . . . . . . . . . . . . 13.9 hp Kubota, 2 cyl, 479cc (model Z482-B)
Engine Oil . . . . . . . . . . . . 3.5 US Qts (3.3L) with filter.
Belt Tension . . . . . . . . . . Alternator 45-55 ft-lb (61-75 N-m).
Engine compression . . . . 327 PSI min. (2.26 MPa min).
Engine Speed . . . . . . . . . Approx. 2400 RPM.
Valve Clearance (Cold) . . . 0.145 to 0.185 mm (0.0057 to 0.0073 in).
Engine Drain Plug . . . . . . Torque 25 ± 2 ft/lb.
10W
5W
5W20
243
253
-30
-20
-22
-4
Intake & Exhaust Valves . 0.0057-0.0073" (0.145 – 0.185 mm) Cold.
Fast Burn Glow Plugs . . . . 0.9 Ohms each, 22 Amps then ramps down
Starter . . . . . . . . . . . . . . 160 Cranking Amps (includes glow plugs and
Alternator . . . . . . . . . . . . 60 Amps @ 14.2 Volts DC.
Generator . . . . . . . . . . . . 35 Amps @ 120 Volts AC.
Fuel Solenoid . . . . . . . . . Pull-in winding 29 Amps, Hold winding 1 Amp.
Oil pressure switch . . . . . Normally closed, opens at 7 psi.
Overheat switch . . . . . . . Normally open, closes at 245°F.
Thermostat . . . . . . . . . . . Starts to open at 160°F and fully opens at 185°F.
CCU
Air Conditioner
System capacity
System Oil capacity . . 14 oz of PVE (Polyvinylether).
Compressor
Condenser Fan
Binary Pressure Switch . Normally closed between 26–335 psi.
Operating pressures . . Low side, 24–45 psi, High side, 110–250 psi.
Condenser Air inlet to outlet temperature difference should be no more
than 30°F. Evaporator Air inlet to outlet temperature difference 18° - 25°F.
Heat . . . . . . . . . . . . . . . 10,000 BTU/ hr (3,000 watts).
Blower Fan low
speed resister . . . . . . 25 Ohms.
Heating Coils . . . . . . . 10 Ohms each.
Thermo Fuse . . . . . . . Blows at 307.4°F (152°C).
You can use any API Service CF, CF-4, CG-4
or CH-4 oil and any ASE Viscosity (or weight) of
Oil according to the chart.
Generator 70-80 ft-lb (95-108 N-m).
30
20
20W
5W30
10W30
15W40
20W50
263
273
283
293
303
-10
0
10
20
30
14
32
50
68
86
to 12 Amps.
fuel solenoid).
. . . . . . . 10,000 BTU/ hr hermetic compressor.
. . . . 64–68 oz of R-134A.
. . . . . . . 6–10 Amps @ 120 Volts.
. . . . . 9-12 Amps .
40
SINGLE
GRADE
MULTI
GRADE
313
323
K
AMBIENT
°C
40
50
TEMP
°F
104
122
62-11175 COMFORTPRO SERVICE MANUAL