ACV BMV1 AND BMV2 OIL BURNERS

Description
For the Delta Performance oil-fuelled balanced flue model, we have
opted for the all-new technology of the ACV BMV1 and BMV2 oil
burner, manufactured from high quality components combining
performance with perfect combustion.
CO
chart for the ACV BMV1 and BMV2 burner
2
14 %
13,5 %
13 %
12,5 %
12 %
-10
0
Outside temperature
ACV BMV1 AND BMV2
BURNER FACTORY SETTINGS
Burner
Input
Nozzle
Nozzle angle
Oil flow
Pump pressure
Flue gas index
Air reducer
Air inlet
Nozzle line pressure
Nozzle line
Weight
WARNING: Set the % of CO
as per the data in the diagram above
2
10
20
30
40
kW
gal/h
Kg/h
bar
%
%
mbar
mm
Kg

BURNER FEATURES

ACV BMV1 AND BMV2 BURNER CAPTIONS
(see illustration O)
1. Control unit
2. Nozzle line protection
3. Warning lamp
4. Electric plug connector
5. Attachment bracket
6. Burner blast tube
7. Ignition unit
8. High tension ignition cable
9. Oil pump
10. Oil aspiration line connection
11. Oil return connection
12. Motor condenser
13. Motor
14. Pump / nozzle connecting pipe
15. Burner casing
16. Nozzle line adjustment screw
FV/35
BMV1
34.9
0,75
60°H
2.95
11.8
0 - 0.5
37
90
3.5 - 4
10
14.5
(circuit with return only)
FV/50
BMV2
50
1.25
60°H
4.22
9.5
0 - 0.5
60
90
3.5 - 4
10
14.5
9