Charnwood LA45iB Operating And Installation Instructions

Charnwood LA45iB Operating And Installation Instructions

Roomheater with boiler

Advertisement

Quick Links

CHARNWOOD
LA45iB & LA50iB
Roomheater With Boiler
Operating
and
Installation Instructions
Bishops Way, Newport, Isle of Wight, PO30 5WS, U.K.
Tel: +44(0)1983 527552 Fax: +44(0)1983 821267
E-Mail: charnwood@ajwells.co.uk Internet: www.charnwood.com

Advertisement

Table of Contents
loading

Summary of Contents for Charnwood LA45iB

  • Page 1 CHARNWOOD LA45iB & LA50iB Roomheater With Boiler Operating Installation Instructions Bishops Way, Newport, Isle of Wight, PO30 5WS, U.K. Tel: +44(0)1983 527552 Fax: +44(0)1983 821267 E-Mail: charnwood@ajwells.co.uk Internet: www.charnwood.com...
  • Page 3: Table Of Contents

    CHARNWOOD LA45iB & LA50iB Operating Installation Instructions Contents Operating Instructions General Points ......3 Fuels ........3 Door Operation .
  • Page 5: General Points

    OPERATING INSTRUCTIONS FOR THE CHARNWOOD LA45iB & LA50iB GENERAL POINTS will be able to advise you if other fuels output is controlled by the control may be burnt. For instructions on knob on the left hand side of the Before lighting the fire check with the burning other fuels please ask your appliance, shown in Fig.
  • Page 6: System Controls

    To make ash removal easier there is a closed. special Charnwood ash carrier available. This may be purchased from Fig. 2. Secondary Air Control OVERNIGHT BURNING Empty the ashpan, if necessary, and...
  • Page 7: Throat Plate And Flueway Cleaning

    period until the fire is burning brightly thermostat should be left at the MAINTENANCE before filling with fuel. maximum setting and the main doors Cleaning left ajar. It is also advisable to sweep If the central heating pump is off The appliance is finished in vitreous the chimney and clean out the fire.
  • Page 8: Boiler Reduction Brick

    insulated chimneys the manufacturers a) the door seals are kept in good sought if necessary. instructions with regard to sweeping condition, and that the doors are should be consulted. sealing correctly, b) the thermostat on the fire is working correctly, BOILER REDUCTION BRICK Lack of Heat To c) a suitable fuel is being used,...
  • Page 9: Health & Safety Precautions

    This must be borne in the complete chimney. The rated output for the LA45iB is mind when calculating the heating 10.1 kW (34500 btu/h) to water and If it is found that there is excessive requirements.
  • Page 10: Preparation Of Fireplace

    combustible material. The positioning be reduced. Fig. 5. shows the ratio of of the appliance and the size of the space heating to water heating which hearth are governed by building can be expected. regulations for Class 1 appliances. Fitting a radiator in the same room as These building regulations state that the fire is recommended as it will allow the hearth must extend in front of the...
  • Page 11: Thermostat

    length of 150mm (6”) internal 22mm Open Vents diameter flue pipe (cast iron to BS41, Feed and Expansion Tank Cold Water Tank 1.0 mm thick stainless steel, or 5.0mm thick mild steel). Overflow Overflow The end of the flue pipe must line up with the centre-line of the chimney, and must also extend to the point where Domestic Hot Water Draw Off...
  • Page 12: Assembly

    On completion of the installation and the air inlet as shown in Fig. 12. To operated. commissioning please leave the adjust the distance slacken the locking 2. The plates round the sides and back operating instructions with the nut and adjust as necessary. When set of the grate must be in position and customer and advise on the use of the correctly re-tighten the locking nut.
  • Page 13: Overall Dimensions

    Charnwood LA45iB & LA50iB Overall Dimensions (Dimensions are in mm) 168 i/d (To suit 150mm flue pipe) Boiler tappings are 1" BSP Female. (2 Each side) Page 11 LA50iB 2.01...
  • Page 14: Exploded Parts Drawing

    Issue L CHARNWOOD LA45iB & LA50iB PARTS LIST Freestanding Kit Nuts, bolts, screws and clips are not shown for clarity. To obtain spare parts contact your local stockist giving Model, Part No. and Description. In case of difficulty contact the manufacturer at the address shown below.

This manual is also suitable for:

La50ib

Table of Contents