LENNOX HEARTH PRODUCTS • RHAPSODY™ LINEAR DIRECT-VENT GAS FIREPLACES (MODEL RHAP54N) • INSTALLATION INSTRUCTIONS
gENERAL
INfORMATION

INTROdUCTION

LENNOX HEARTH PRODUCTS Rhapsody™
models are direct-vent (top vent only), sealed
combustion, air-circulating gas fireplaces
designed for residential applications.
Direct-vent appliances operate with the com-
bustion chamber isolated from the indoor
environment. All air for combustion is brought
in from the outside, and exhaust gases are
vented through the same direct-vent, coaxial
(intake/exhaust) vent system.
These appliances are designed to operate
on natural or propane gas only. The use of
other fuels or fuel combinations will degrade
the performance of this system, may be
dangerous, and may void the warranty.
The electronic system is switchable between
standing and intermittent pilot modes (see
Figure 11-2).
The Total Comfort Control™ Remote Control
System is included with all models and provides
remote operation of several fireplace functions
(manual adjustment of the gas valve settings is
not possible). See Page 25 for details.
Electrical power (110 Vac line voltage) is rec-
ommended to operate the fireplace; however,
"AA" batteries can be used for full-time opera-
tion or as a backup in case of a power outage.
Note: Batteries will operate the gas valve
OPEN/CLOSE and pilot ON/OFF functions
only. Electrical power (110 Vac line volt-
age) is required to operate the following
optional components (bat teries will not
power any of these options):
•  Blower Kit
•  Power Vent System
•  Panel Backlighting Kit
4

EffICIENCIES

EffICIENCIES
Natural gas
fireplace
Model
Energuide
AfUE*
RHAP54N 70.2%
*AFUE (Annual Fuel Utilization Efficiency) is the 
recognized  U.S.  rating  system  for  the  total  effi-
ciency of heating products.
Figure 4-1

LISTINg INfORMATION

These appliances comply with National Safety
Standards and are tested and listed by Intertek
(Report No. 100404899PRT-001) to ANSI
Z21.88 (in Canada, CSA-2.33), and CAN/
CGA-2.17-M91 (CSA P4.1) in both USA and
Canada, as vented gas fireplace heaters.
These appliances are listed by Intertek for
installation in bedrooms, aftermarket mobile
homes, and manufactured homes.

COdES

Installation must conform to local codes or, in
the absence of local codes, with the National
Fuel Gas Code, ANSI Z223.1/NFPA 54, latest 
edition (in Canada, the current CAN/CSA-
B149.1 installation code).
The appliance, when installed, must be electri-
cally grounded and wired in accordance with
local codes, or, in the absence of local codes,
with the National Electrical Code, ANSI/NFPA 
70, latest edition, or the Canadian Electrical
Code, CSA C22.1, latest edition.
NOTE: DIAGRAMS AND ILLUSTRATIONS ARE REPRESENTATIVE AND ARE NOT DRAWN TO SCALE.
www.LennoxHearthProducts.com
REqUIREMENTS fOR COMMON-
WEALTH Of MASSACHUSETTS
These fireplaces are approved for installation in
Propane
the US state of Massachusetts if the following
(field-converted)
additional requirements are met:
Energuide
AfUE*
• Install appliance in accordance with Massa-
(P4)
(P4)
66.9%
69.8%
71.8%
• Installation and repair must be done by a
• The flexible gas line connector used shall
• The individual manual shutoff must be a
Massachusetts Horizontal Vent
Requirements
In the Commonwealth of Massachusetts, hori-
zontal terminations installed less than seven
(7) feet above the finished grade must comply
with the following additional requirements:
• A hard-wired carbon monoxide detector
• A metal or plastic identification plate must
COLd CLIMATE INSULATION
REqUIREMENTS
For cold climate installations:
• Use noncombustible caulk to seal all joints
• Caulk all gas line holes and other openings
• Caulk firestops only where pipe penetrates
• If the floor is above ground level, insulate
• If installing the fireplace on a cement slab,
• Drywall and tape all inside sur faces of sur-
chusetts Rules and Regulations 248 C.M.R.
plumber or gas fitter licensed in the Com-
monwealth of Massachusetts.
not exceed 36 inches (92 centimeters) in
length.
T-handle type valve.
with an alarm and battery backup must be
installed on the floor level where the gas
fireplace is installed. The carbon monoxide
detector must comply with NFPA 720, be
ANSI/UL 2034 listed and be ISA certified.
be permanently mounted to the exterior of
the building at a minimum height of eight (8)
feet above grade and be directly in line with
the horizontal termination. The sign must
read, in print size no less than one-half (1/2)
inch in size: GAS VENT DIRECTLY BELOW.
KEEP CLEAR OF ALL OBSTRUCTIONS.
around the appliance and wherever cold air
could enter the room.
(or stuff with unfaced fiberglass insulation).
an outside wall, attic, or other other uncon-
ditioned space.
the outside chase cavity between the studs
and under the floor beneath the appliance.
place a sheet of plywood or other raised
platform underneath to prevent cold transfer
to the fireplace and into the room.
rounding chase for maximum air tightness.