GD AQUALINE 1100 Installation & Operating Instructions Manual page 28

Table of Contents

Advertisement

Operation
Possible cause
Safety valve blowing
Closed valves in pressure line
Pressure pipework blocked
Compressed air exits at shaft end and water leaks
Seal damaged
Rubber smell (with Vee belt drive)
Vee belt slip due to lack of belt tension
High output pressure
Vee belts buckling
Lack of belt tension
Belt wear
Belt pulley out of alignment
Belt pulley wear
1)The cause of abnormal noise in the machine
can be a foreign object; remove the foreign ob-
ject without delay.
If the problem persists, please call our Service depart-
ment.
4990671000 February 2008
Remedy
Open valves
Remove blockage
Replace shaft seal in end cover or have it repaired
Check belt tension, re-tension if necessary
Keep within rated pressure
Check belt tension, retension if necessary
Install new Vee belts
Align pulley
Replace pulleys