4.3

Point of installation and fastening

The point of installation on the vehicle must
be easy to access,
be protected from dirt, the impact of stones and
water splash.
leave sufficient space for the connection of operat-
ing water, the suction and pressure lines and the
operating water drain.
be accessible for maintenance (for regreasing the
grease barrier).
Fasten the machine at the 4 feet (M16 tapped holes).
The machine can be fastened directly onto a suitable
frame. The minimum depth of thread engagement is
23 mm.
Framework must be of sufficient strength to support
machine in operation and while vehicle is driven.
The four fastening points (machine foot supports) must
be in exact alignment.
For dimensions and weights, see chapter 1. "Technical
data".
The machine must be adequately earthed.
An equipotential earth bonding strap should
be securely fastened between the machine
body and a suitable point on the vehicle
frame.
Ensure that the machine and all ancilliaries
are earthed in accordance with BS5958 Pt1:
1991;
'Control of undesirable Static Electricity'.
4990671000 February 2008
4.4

Connections and piping

For regular service of the liquid ring pump the suction,
pressure lines, operating water supply, and water drain
line must be connected to the machine
The various possibilities of the suction and pressure
line connections are illustrated in figure 4.5 for ma-
chines of clockwise and counterclockwise rotation.
Pressure side
connection on one
flange optional
Suction side
connection on one
flange optional
counter clock wise Operation
Fig. 4.5
Aqualine 1100 to 2700 connection versions
The suction and pressure line, respectively, can either
be connected on the A side or B side. The same ap-
plies to the operating water supply, the drain line and
the venting line.
As regards piping, the minimum pipe diameters in the
table below are recommended.
Aqualine
1100
Suction line
DN 125
(5")
Pressure line
DN 125
(5")
15
Installation
Suction side
connection on one
flange optional
Top view
clock wise Operation
Pressure side
connection on one
flange optional
Top view
1600
2100
DN 125
DN 125
(5")
(5")
DN 125
DN 125
(5")
(5")
2700
DN 125
(5")
DN 125
(5")