INSTALLATION MANUAL Ceiling And Floor Type KFUF SERIES Thank you very much for purchasing our air conditioner, Before using your air conditioner , please read this manual carefully and keep it for future reference.
Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electrical shock and fire. CONTENTS PAGE When installing the unit in a small room, take measures against to keep refrigerant concentration from exceeding allowable safety limits in the event of refrigerant leakage. PRECAUTIONS..................1 Contact the place of purchase for more information.
2. INSTALLATION INFORMATION If the refrigerant leaks during installation, ventilate the area immediately. Toxic gas may be produced if the refrigerant comes into the place contacting with fire. To install properly, please read this "installation manual" at The temperature of refrigerant circuit will be high, please first.
3. ATTACHED FITTINGS Please check whether the following fittings are of full scope. If there are some spare fittings , please restore them carefully. NAME SHAPE QUANTITY 3. Remote controller (on some models) 4. Remote controller holder (on some models) Remote controller &...
5.2 Install the main body 4. INSPECTING AND HANDLING THE UNIT At delivery, the package should be checked and any damage should be reported immediately to the the service agent. When handling the unit, take into account the following: Fragile, handle the unit with care. Keep the unit upright in order to avoid compressor D.
2. Ceiling Installation NEW CONCRETE BRICKS Inlaying or embedding the screw bolts. (Blade shape (Slide insertion) Fig.5-4 insertion) Steel bar Fig. 5-10 Embedding screw bolt Fig.5-5 (Pipe hanging and embedding screw bolt) D. Connecting point of refrigerant pipe (D.gas side) FOR ORIGINAL CONCRETE BRICKS E.
Page 7
6.2 Figure of body size The piping length between the outdoor unit and the indoor unit may not exceed the allowable piping length. In the case that the installation place is exposed to strong Split type outdoor unit wind such as a seaside, make sure the fan operating properly by putting the unit lengthwise along the wall or using a dust or shield.(Refer to Fig.6-1) If possible, do not install the unit where it is exposed to...
Page 8
3. Centrifugal fan type outdoor unit Table 6-1 unit:mm MODEL REMARK Fig.6-2 Fig.6-2 Fig.6-2 Fig.6-2 Fig.6-2 Fig.6-2 Fig.6-2 Fig.6-2 Fig.6-7 Fig.6-2 1245 Fig.6-3 unit:mm Table 6-3 Fig.6-2 MODEL 1245 Fig.6-3 1174 1120 Fig.6-2 1174 1120 680 1245 Fig.6-3 1381 1328 1167 Fig.6-3 1381 1328 702...
Page 9
Air inlet modification To change air inlet is only necessary to interchange the indicated panels position. Both panels screws to be fixed (Wall or obstacle) to unit chassis. >30cm >30cm Air inlet Air inlet Fig.6-10 Change Panel Fig6-13 3. Centrifugal fan type outdoor unit To change air outlet is necessary to interchange panels too.
7. INSTALL THE CONNECTING PIPE Check whether the height drop between the indoor unit and outdoor unit, the length of refrigerant pipe, and the number of ≥ 100 the bends meet the following requirements: (The number of the bends less than 15) Table 7-1 The length of The max...
Page 11
Remove the protection cover of stop valve Bind the connecting pipe and the cables together tightly with binding tapes.Pass the bound connecting pipe through the wall conduct from outside. Be careful of the pipe allocation to do on damage to the tubing. Connect the pipes.
Closing stop valve Manifold valve Remove the cap and turn the valve clockwise with the Multi-meter Pressure meter hexagon wrench. -76 cmHg Securely tighten the valve until the shaft contacts the Hi-lever Lo-lever main bodyseal. Charge hose Charge hose Make sure to tighten the cap securely. Vacuum pump For the tightening torque, refer to the table below.
CAUTION The drain pipe of indoor unit must be heat insulated, or it will condense dew, as well as the connections of the indoor unit. Hard PVC binder must be used for pipe connection, and make sure there is no leakage. With the connection part to the indoor unit, please be noted not to impose pressure on the side of indoor unit pipes.
NOTE NOTE All the figures in this manual are for explanation Remark per EMC Directive 2004/108/EC. purpose only. They may be slightly different from the air For to prevent flicker impressions during the start of the conditioner you purchased.The actual unit shall prevail. compressor (technical process)
Page 15
The Specification of Power(indoor power supply) Table 9-1 MODEL 30~36 42~48 PHASE 1 P h a s e 1 P h a s e 1 P h a s e 1 P h a s e 1 P h a s e POWER FREQUENCY AND VOLT 208-240 V...
Page 16
The Specification of Power(independence power supply) Table 9-5 MODEL 30~36 42~48 PHASE 1 P h a s e 1 P h a s e 1 P h a s e 1 P h a s e 1 P h a s e POWER (indoor) FREQUENCY AND VOLT...
CAUTION The power supply is included in the power supply above mentioned can be applied to the table. Wiring figure Fig.9-5 Power supply Switch/Fuse (Available locally) Power wiring (indoor) Power linking wiring (Outdoor) Indoor Outdoor Unit Unit Ground wiring Strong elec-signal link wiring Ground wiring Weak elec-signal link wiring Ground the air conditioner properly in case to affect its anti-interference function...
Page 18
Fig.9-7 Power supply Power supply Switch/Fuse (Available locally) Power wiring (indoor) Power linking wiring (Outdoor) Indoor Unit Out door Unit Ground wiring Weak elec-signal link wiring Ground wiring Ground the air conditioner properly in case to affect its anti-interference function Fig.9-8 Power supply Switch/Fuse...
Page 20
The Klimaire logo is a registered Trademark of Klimaire Products inc. Copyright 2014 Klimaire Products Inc. 2190 NW 89 Place, Doral, FL 33172 - USA Tel: (305)593-8358 Fax (305) 675-2212 www.klimaire.com sales@klimaire.com The design and specifications are subject to change without prior notice for product...