camera operation
COMM ADJ (Communication Adjustment) : This function sets up the camera
communication status when controlling the camera through an external control device.
➊
When the SPECIAL menu screen is
displayed, press the set button so that
the arrow indicates 'COMM ADJ'.
➋
Set up the mode using the Function
Setup button.
-
CAM ID : Determines the camera's identification
-
BAUD RATE : You can select 2400/4800/
-
UART MODE : You can select NONE, EVEN or ODD for the parity bits.
-
RET PKT : Determines whether to send a command back to the controller device
-
DISP ID : Display camera title on top left corner of the screen.
-
PROTOCOL : Select the communication PROTOCOL. (SAMSUNG-T, SAMSUNG-E ,
-
COAX : Specify the use of coaxial communications.
If you encounter an error due to noise from the DVR, you can set the sensitivity
level of the sub menu item to "Low " in an attempt to prevent the error. Then,
you must press the MENU/ENTER (OSD KEY) button twice in a row to access
the OSD menu.
-
RETURN : Select this to save the PRIVACY menu settings and return to the
* Initial value of communication adjustment
Item
Initial value
RETURN : Select this to save the SPECIAL menu settings and return to the MAIN
36_ camera operation
number (between 0 and 255).
9600/19200/38400/57600
bps.
when a communication control command is sent to the camera.
PELCO-D, PELCO-P, BOSCH, HONEYWELL, VICON PANA., GE and AD)
SPECIAL menu.
Camera ID
BAUD RATE UART MODE
1
SETUP menu.
1. CAM ID
2. BAUD RATE
3. UART MODE
4. RET PKT
5. DISP ID
6. PROTOCOL
7. COAX
8. RETURN
9600
8-NONE-1
COMM SETUP
IIIIIIIIIIIIIIIIIIIII
ENABLE
SAMSUNG-T
PET PKT
ENABLE
1
9600
8-N-1
OFF
ON