Advertisement

FOCUS HE SLIMLINE
Please read these instructions carefully before you start
Keep this booklet handy for future reference
A QUALITY PRODUCT FROM PARAGON FIRES
OWNER'S
MANUAL
using the appliance
This appliance is
for use in Great Britain or
IRELAND only
This appliance is
for use in Great Britain or
IRELAND only

Advertisement

Table of Contents
loading

Summary of Contents for Paragon Fires FOCUS HE SLIMLINE

  • Page 1 Please read these instructions carefully before you start using the appliance Keep this booklet handy for future reference This appliance is for use in Great Britain or IRELAND only This appliance is for use in Great Britain or IRELAND only A QUALITY PRODUCT FROM PARAGON FIRES...
  • Page 2 FOCUS HE SLIMLINE Instructions CONTENTS PAGE USERS INSTRUCTIONS SECTION ONE Introduction SECTION TWO Operating Appliance SECTION THREE Fuel Bed Cleaning and Layout SECTION FOUR Cleaning SECTION FIVE General Points INSTALLATION INSTRUCTIONS SECTION SIX Appliance Data SECTION SEVEN Regulations and Warnings...
  • Page 3: Users Instructions

    „hazardous waste' and should be disposed of at a site licensed for the disposal of industrial waste.  The FOCUS HE SLIMLINE is a decorative fuel effect appliance with a radiant heat conserver box and glass panel for improved efficiency.
  • Page 4: Operation

    SECTION ONE Important Information Continued INTRODUCTION The FOCUS HE SLIMLINE incorporates a single gas control, which selects ignition pilot, and main burner low and high settings. The appliance incorporates a safety device in the form of an Oxygen Depletion System, which constantly monitors the oxygen in the room and will cause the fire to switch off if the oxygen level reduces, for instance due to insufficient ventilation or a blocked flue.
  • Page 5: Removing Glass Panel

    FOCUS HE SLIMLINE Users Instructions SECTION THREE Fuel Bed Cleaning and Layout Warning: - Before you clean any part of the appliance ensures that the appliance is turned off and cold. Important: - Refer to the ‘Health & Safety Notice located on page 3 of this booklet before cleaning or replacing any refractory material.
  • Page 6: Fuel Bed Layout

    FOCUS HE SLIMLINE Users Instructions SECTION THREE Fuel Bed Cleaning and Layout 6 OFF “A” Coal Shapes 9 OFF “B” Coal Shapes FUEL BED LAYOUT (COAL OPTION)  Ensure the BASE MATRIX is in position as shown located against the rear edge of the burner outlet.
  • Page 7 FOCUS HE SLIMLINE Users Instructions SECTION THREE Fuel Bed Cleaning and Layout Continued  Lay the third layer of coal as shown.  Refit glass panel, heat shield, canopy, trim and fret. 6 OFF “A” Pebble Shapes 9 OFF “B” Pebble Shapes FUEL BED LAYOUT (PEBBLE OPTION) ...
  • Page 8: Cleaning: Black Painted Surfaces

    FOCUS HE SLIMLINE Users Instructions SECTION THREE Fuel Bed Cleaning and Layout Continued  Lay a second layer of Pebbles as shown.  Lay the third layer of coal as shown. Note: The appliance MUST no be used if the canopy or glass panel is missing or damaged.
  • Page 9: Cleaning: Pilot Assembly

    Like all appliances incorporating an aerated burner a low frequency noise may be heard. It is advised that the FOCUS HE SLIMLINE fire be serviced annually by a competent person. The fire is more likely to provide trouble-free operation. The actions given below should be carried out during that service.
  • Page 10: Installation Instructions

    FOCUS HE SLIMLINE Installation Instructions SECTION SIX Appliance Data Category of Appliance Category Gas Type Gas Pressure: 20 mbar 1.0mbar Gas Input (Gross) 4.2 kW (Max.) 2.40 kW (Min) Injectors: Size 290 Oxy-pilot 9044NG Data Badge Location:(Behind trim) right hand side of the appliance.
  • Page 11: Regulations And Warnings

    FOCUS HE SLIMLINE Installation Instructions SECTION SEVEN Regulations and Warnings Consumer Protection Information As manufacturers and suppliers of heating products, we take every care, as far as is reasonably practicable, that these products are so designed and constructed as to meet the general safety requirement when properly used and installed.
  • Page 12 FOCUS HE SLIMLINE Installation Instructions SECTION SEVEN Regulations and Warnings Continued  THIS APPLIANCE MUST ONLY BE INSTALLED IN Great Britain OR IRELAND.  THE APPLIANCE IS SUITABLE FOR USE ON NATURAL GAS ONLY.  THE APPLIANCE IS INTENDED FOR DECORATIVE PURPOSES.
  • Page 13: Siting The Appliance

    FOCUS HE SLIMLINE Installation Instructions SECTION EIGHT Siting the Appliance The fire can be installed in the following locations: - CLASS ONE & CLASS TWO & PRE-CAST A conventional brick or stone chimney as used for a solid fuel appliance with an effective cross- sectional dimension of 225 x 225 mm (9 x 9 INS) or a clay/ceramic/metal lined flue with a minimum diameter of 125mm (5 INS).
  • Page 14: Soft Furnishings

    FOCUS HE SLIMLINE Installation Instructions SECTION EIGHT Siting the Appliance continued PURPOSE BUILT HEARTH AND SURROUND Purpose built superimposed fire-resistant hearths and back panels, specified as suitable by the manufacturers, may be used, or a suitable proprietary fire surround with a 150 C minimum rating.
  • Page 15: Checking The Flue And Fire Opening

    FOCUS HE SLIMLINE Installation Instructions SECTION NINE To Install the Appliance CHECKING THE FLUE AND FIRE OPENING  Check that the chimney conforms to the required specifications as previously stated. Examine the condition and carry out any remedial work including any removal of debris from the base.
  • Page 16: Connecting The Gas Supply

    FOCUS HE SLIMLINE Installation Instructions SECTION NINE To Install the Appliance continued CONNECTING THE GAS SUPPLY Note:- An isolation valve (supplied) should be fitted in the gas supply .This will facilitate servicing. For a concealed connection: -  After removing the glass panel as described above.
  • Page 17: Checking Gas Soundness

    FOCUS HE SLIMLINE Installation Instructions SECTION NINE To Install the Appliance continued CHECKING GAS SOUNDNESS  Turn on the gas supply to the appliance and check for soundness in accordance with current codes of practice.  Turn off the gas supply at the external Isolation valve.
  • Page 18 FOCUS HE SLIMLINE Installation Instructions SECTION TEN Checking Operation of Fire THE FIRE FRET AND DECORATIVE TRIM FIT FIRE TRIM AND FRET  Fit the fire with the magnetic strips placed on the vertical side flange of the box. ...
  • Page 19: Maintenance Instructions

    FOCUS HE SLIMLINE Maintenance Instructions SECTION ELEVEN Maintenance GENERAL  Servicing should be carried out annually by a competent person such as a CORGI-registered person in accordance with the relevant regulations, to ensure the safe and correct operation of the appliance.
  • Page 20: Replacement Of Injector

    FOCUS HE SLIMLINE Maintenance Instructions SECTION ELEVEN Maintenance Continued REPLACEMENT OF BURNER AND OR THE SILENCER NOTE: The silencer must not be modified and must be correctly positioned in its bracket (i.e. open end facing injector). 1. Turn off the gas supply by isolating cock.
  • Page 21 Paragon Fires FOCUS HE SLIMLINE THIS IS YOUR EXTENDED FIVE YEAR PARTS WARRANTY PLEASE READ IT CAREFULLY AND ENSURE YOUR INSTALLER HAS FILLED IN THE FIRST PORTION, KEEP IT IN A SAFE PLACE SO THAT IT IS AVAILABLE CORGI WHEN YOUR ENGINEER CARRIES OUT THE ANNUAL SERVICE.
  • Page 22: Warranty Cover

    The following information must be complete and supported by receipts as part of the conditions of the extended three year parts warranty and the appliance must be registered by completing and returning the registration document (last page of this booklet) to Paragon Fires. Date of First annual service: Engineer Name Corgi Registration No.
  • Page 23 Post Code TELEPHONE No. PRODUCT DETAILS Model: PARAGON FOCUS HE SLIMLINE Serial No. Date of Purchase This information can be found on the label attached to the packaging and on the data badge, which is located on the appliance flange, top right behind trim.
  • Page 24 Focus HE Slimline Coal Product Serial ID Label A-0134 Prefix Fire Box Labels Spillage (1057) Data Badge Fire Box Grommet Burner Tray / Box Assembly Warning Label (Fire Guard) Coal Set 5322 Rear Matrix 5319 Front Matrix 5320 Glass Panel...

Table of Contents