Advertisement

PARAGON 2000 Plus
And 2000 Plus Xtra
Owner's Book
INCLUDES USER, INSTALLATION &
MAINTENANCE INSTRUCTIONS
Please read these instructions carefully before you start using the
appliance
Keep this booklet handy for future reference
This appliance is
for use in GREAT BRITAIN or IRELAND
only
A QUALITY PRODUCT FROM PARAGON FIRES

Advertisement

Table of Contents
loading

Summary of Contents for Paragon Fires 2000 Plus Xtra

  • Page 1 INCLUDES USER, INSTALLATION & MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start using the appliance Keep this booklet handy for future reference This appliance is for use in GREAT BRITAIN or IRELAND only A QUALITY PRODUCT FROM PARAGON FIRES...
  • Page 2: Table Of Contents

    PARAGON 2000 Plus Instructions CONTENTS CONTENTS PAGE User Instructions SECTION ONE Introduction Consumer Protection Health and Safety Introduction SECTION TWO Operation SECTION THREE Fuel Bed Cleaning and Layout Coal Layout Pebble Layout SECTION FOUR Important information INSTALLATION INSTRUCTIONS SECTION FIVE Specification SECTION SIX Regulations and Warnings SECTION SEVEN Siting the Appliance Class One...
  • Page 3: User Instructions

    PARAGON 2000 Plus Users Instructions SECTION ONE Introduction Consumer Protection Information As manufacturers and suppliers of heating products, we take every care, as far as is reasonably practicable, that these products are so designed and constructed as to meet the general safety requirement when properly used and installed. To this end, our products are thoroughly tested and examined before despatch.
  • Page 4: Section Two Operation

    PARAGON 2000 Plus Users Instructions SECTION ONE Introduction Continued The PARAGON 2000 Plus incorporates a single gas control, which selects ignition pilot, and main burner low and high settings. The PARAGON 2000 Plus incorporates a safety device in the form of an Oxygen Depletion System, which constantly monitors the oxygen in the room and will cause the fire to switch off if the oxygen level reduces, for instance due to insufficient ventilation or a blocked flue.
  • Page 5: Section Three Fuel Bed Cleaning And Layout

    PARAGON 2000 Plus Users Instructions SECTION THREE Fuel Bed Cleaning and Layout Important: - Refer to the ‘Health & Safety Notice located on page 3 of this booklet before cleaning or replacing any refractory material. The fuel bed components are delicate and they should be handled with great care. The loose parts and moulded shapes may be removed for cleaning.
  • Page 6 PARAGON 2000 Plus Users Instructions SECTION THREE Fuel Bed Cleaning and Layout Cont.  Slide front support over front edge of fire where the left & right front coals meet, see below. Note the loose coal provided consist of :- 5 off shaped as coal "A"...
  • Page 7 PARAGON 2000 Plus Users Instructions SECTION THREE Fuel Bed Cleaning and Layout Cont.  Lay second row of loose coals 3 off "B" and 2 off “A” shapes as shown.  Lay third row of loose coals 2 off "B" shape and 1 off “A“...
  • Page 8: Pebble Layout

    PARAGON 2000 Plus Users Instructions SECTION THREE Fuel Bed Cleaning and Layout Cont. FUEL BED LAYOUT (PEBBLE OPTION) FUEL BED COMPONENTS  Base Matrix  L & R Front Pebbles  Number Pebbles as below:- Pebble identification Heart Shape Oblong Shape Large Shape Medium Shape Small Shape...
  • Page 9 PARAGON 2000 Plus Users Instructions SECTION THREE Fuel Bed Cleaning and Layout Cont.  Lay one row of pebbles at the front of the fire as shown.  Lay another row of loose pebbles shown.  Lay another row of loose pebbles as shown. LT5048 (Iss 9: 11/12)
  • Page 10: Section Four Important Information

    PARAGON 2000 Plus Users Instructions SECTION FOUR Important Information The only user removable parts are: -   The loose pebbles or coals . The base matrix   The left hand front pebble or coal Cast Fret  shape. Decorative Trim ...
  • Page 11: Installation Instructions

    PARAGON 2000 Plus Installation Instructions SECTION FIVE Specification NATURAL GAS PROPANE GAS Category of Appliance: Category Gas type: Gas Pressure: 20 mbar 37 mbar Gas input high: 7.00 kW Gross 7.00 kW Gross Gas input low: 2.40 kW Gross 2.40 kW Gross Injector Main: Size 460A Size 135...
  • Page 12: Section Seven Siting The Appliance

    PARAGON 2000 Plus Installation Instructions SECTION SIX Regulations and Warnings Continued  A non-combustible hearth must be provided to comply with the building regulations or a suitable proprietary fire surround with a 100 degrees C rating.  During initial firing an odour may be evident. This is the binder used during the manufacture of the fibre components and there are no harmful effects produced.
  • Page 13: Class Two Pre-Cast Flue

    PARAGON 2000 Plus Installation Instructions SECTION SEVEN Siting the Appliance Continued  CLASS TWO PRE-CAST A pre-cast flue conforming to the requirements of BS 1289 part 1 & 2 A suitable fire resisting fire surround will be required, spaced out to the correct thickness, between the face of the flue blocks and the rear of the appliance frame.
  • Page 14: Hole In The Wall Installations

    Frets, and Fascias used for HOLE in the WALL must be compliant with Paragon Fires CE approval; these are listed at the end of this page.
  • Page 15: Clearance To Shelf

    PARAGON 2000 Plus Installation Instructions SECTION EIGHT Fireplace Requirements Continued CLEARANCE TO SHELF Minimum clearance from hearth to underside of combustible shelf should be 700mm provided shelf depth 150mm or less. This height may be reduced to 640mm for a shelf depth of 100mm or less When the shelf depth is increased by increments of 12.5 mm greater than 150mm, add 25mm to the 700mm minimum clearance.
  • Page 16: Gas Concealed Connection

    OPTIONAL CABLE FIXING SYSTEM (Available on request from PARAGON FIRES) (for use when fixing to 18" openings or when it is desirable not to drill the...
  • Page 17: Checking Gas Soundness

    PARAGON 2000 Plus Installation Instructions SECTION NINE To Install the Appliance Continued Fix the fire casing back into the opening using the cable fixing CLAMP SCREW system as shown in do not cut off loose ends of cable after fixing, coil and tuck carefully behind sides of Refractory back Note: when using the cable...
  • Page 18: Completion Of Installation

    PARAGON 2000 Plus Installation Instructions SECTION NINE To Install the Appliance Continued If an extractor fan is situated in the room this test should be repeated with the fan running. If there is a connected room with an extractor fan, the test should be repeated with all the doors to that room opened and the extractor fan running.
  • Page 19: Fuel Bed Cleaning

    PARAGON2000Plus Maintenance Instructions SECTION TEN Maintenance Instructions continued FUEL BED CLEANING Important: - Refer to the ‘Health & Safety Notice located on page 3 of this booklet before cleaning or replacing any refractory material. The fuel bed components are delicate and they should be handled with great care. The loose parts and moulded shapes may be removed for cleaning.
  • Page 20: Replacement Of Injector

    Remove ignitor lead from pilot assembly. Undo the two screws securing the oxy-pilot to the burner. Re-assemble the in reverse order. Turn on the gas supply, check for gas soundness and re-commission appliance. Paragon Fires Telford Shropshire TF7 4QJ Telephone 01952 278 020 Web Site www.paragonfires.co.uk...
  • Page 21: Annual Service

    Paragon Fires PARAGON 2000 Plus THIS IS YOUR EXTENDED FIVE YEAR PARTS WARRANTY PLEASE READ IT CAREFULLY AND ENSURE YOUR INSTALLER HAS FILLED IN THE FIRST PORTION, KEEP IT IN A SAFE PLACE SO THAT IT GAS SAFE IS AVAILABLE WHEN YOUR ENGINEER CARRIES OUT THE ANNUAL SERVICE.
  • Page 22 WARRANTY COVER Important For future reference we suggest you record the following details here, and keep the receipt as proof of purchase. This information may be asked for when you contact the helpdesk. Model: 2000 Plus Serial No. This information can be found on the label attached to the packaging and on the data badge, which is located on the appliance flange, top right behind trim.
  • Page 23: Service Log

    The following information must be complete and supported by receipts as part of the conditions of the extended three year parts warranty and the appliance must be registered by completing and returning the registration document (last page of this booklet) to Paragon Fires. Date of First annual service: Engineer Name Gas Safe Registration No.
  • Page 24 LT5048 (Iss 9: 11/12)
  • Page 25 PLEASE REGISTER YOUR 12 MONTH WARRANTY WITH US TODAY Simply detach this sheet from this booklet, complete and return it in a stamped addressed envelope to: PARAGON FIRES Charlton and Jenrick Ltd UNIT D STAFFORD PARK 2 TELFORD SHROPSHIRE TF3 3AR...
  • Page 26 LT5048 (Iss 9: 11/12)
  • Page 27 LT5048 (Iss 9: 11/12)
  • Page 28 2000 Plus Packing – Coal 2000 Plus Packing – Pebble Product Product A-0024 / A-0316 (NG) Serial No Serial No ID Label A-0025 Prefix Prefix A-0026 (LPG) Label Burner Tray / Box Assembly Burner Tray / Box Assembly Ceramics Set (Part no 5568) Ceramics Set (Part no 4989) Fixing kit (0705) (includes 4 magnets &...