Paragon Fires ROOM SEALED INSET LIVE FUEL EFFECT GAS FIRE Owner's Manual

Paragon focus rs plus l.p.g

Advertisement

Quick Links

PARAGON FIRES
PARAGON FOCUS RS PLUS
L.P.G Manual Version
ROOM SEALED INSET LIVE FUEL EFFECT GAS FIRE
OWNER'S
MANUAL
Please read these instructions carefully before you start
using the appliance
Keep this booklet handy for future reference
This appliance is
for use in GREAT BRITAIN or
IRELAND only
TELFORD
SHROPSHIRE
ENGLAND

Advertisement

Table of Contents
loading

Summary of Contents for Paragon Fires ROOM SEALED INSET LIVE FUEL EFFECT GAS FIRE

  • Page 1 PARAGON FIRES PARAGON FOCUS RS PLUS L.P.G Manual Version ROOM SEALED INSET LIVE FUEL EFFECT GAS FIRE OWNER'S MANUAL Please read these instructions carefully before you start using the appliance Keep this booklet handy for future reference This appliance is...
  • Page 2: Table Of Contents

    PARAGON FOCUS RS PLUS Instructions CONTENTS PAGE User’s Instructions SECTION ONE Important Information Consumer Protection Health and Safety Notice SECTION TWO Introduction SECTION THREE Operation Lighting the Fire Turning Off the Fire SECTION FOUR Cleaning and Coal Laying Cleaning Decorative Trim Cleaning: Black Painted Surfaces Cleaning: Glass Panel Cleaning and Replacing Coals...
  • Page 3: Paragon Focus Rs Plus

    PARAGON FOCUS RS PLUS Users Instructions SECTION ONE Important Information Consumer Protection Information As manufacturers and suppliers of heating products, we take every care, as far as is reasonably practicable, that these products are so designed and constructed as to meet the general safety requirement when properly used and installed.
  • Page 4 PARAGON FOCUS RS PLUS Users Instructions SECTION ONE Important Information Cont.  As the PARAGON FOCUS RS PLUS is a room sealed appliance (i.e. air for the combustion process is taken from outside the room) no purpose built ventilation is requires. ...
  • Page 5: Section Two Introduction

    PARAGON FOCUS RS PLUS Users Instructions SECTION TWO Introduction  The PARAGON FOCUS RS PLUS is an inset room sealed live fuel-effect gas appliance designed for use in locations that do not have a conventional chimney. The appliance must be installed against an outside wall because the air to support combustion is taken from the outside and the products of combustion are expelled to the outside.
  • Page 6: Section Four Cleaning And Coal Laying

    PARAGON FOCUS RS PLUS Users Instructions SECTION FOUR Cleaning & Fuel Bed Laying Warning: -Before you clean any part of the appliance ensure that the appliance is switched off and cool. CLEANING: DECORATIVE TRIM  The Decorative finish of the trim is coated with a high temperature lacquer, it should be wiped with a soft, clean, dry, cloth only.
  • Page 7: Cleaning And Replacing Coals

    PARAGON FOCUS RS PLUS Users Instructions SECTION FOUR Cleaning & Fuel Bed Laying Continued Note: - If the fuel bed has not been placed correctly, causing the gas flame to contact the glass this may result in glass staining that cannot be removed by cleaning. Re-assemble in reverse order ensuring the seal is compressed evenly at the top and bottom Re-fit the top outlet grill before re-fitting the trim and fret and before re-lighting.
  • Page 8 PARAGON FOCUS RS PLUS Users Instructions SECTION FOUR Cleaning & Fuel Bed Laying Continued COAL BED LAYOUT  The Coal set as shown consists of: Rear Matrix Front Matrix 10 x Individual Coals  The Front Matrix is located as shown in front of the burner ...
  • Page 9: Section Five Replacement Parts

    PARAGON FOCUS RS PLUS Users Instructions SECTION FOUR Cleaning & Fuel Bed Laying Continued  Insert back row of 4 coals as shown.  Complete front row of 6 coals as shown.  That completes the coal bed assembly  Go to section eleven to complete appliance assembly...
  • Page 10: Installation Instructions

    PARAGON FOCUS RS PLUS Installation Instructions SECTION SIX Appliance Data Wall Cut-out dimensions: Height 553mm Width 405mm Overall dimensions: Height 601mm Width 501mm Forward Projection: 90mm, (From fireplace opening Including typical fret.) Weight: 38.5kg (Boxed excluding fret) 37kg (Unboxed excluding fret) Flue Length and duct length: 100mm (minimum) to l metre (maximum) Standard length supplied with fire-535mm (267mm...
  • Page 11: Section Seven Regulations And Warnings

    PARAGON FOCUS RS PLUS Installation Instructions SECTION SEVEN Regulations and Warnings  THIS APPLIANCE MUST ONLY BE INSTALLED IN GREAT BRITAIN OR IRELAND.  THE APPLIANCE IS AVAILABLE IN L.P.G. GAS only.  CONFIRM THAT THE APPLIANCE IS SUITABLE PRIOR TO INSTALLATION (G31 FOR PROPANE GAS) (REFER TO DATA BADGE ON BASE OF APPLIANCE).
  • Page 12: Section Eight Siting The Appliance

    PARAGON FOCUS RS PLUS Installation Instructions SECTION EIGHT Siting the Appliance (When installing in a timber framed dwelling reference must be made to the specific installation requirements stated in Section 10 Installing the Appliance in Timber Framed Dwelling). THERE ARE TWO TYPES OF INSTALLATION (into conventional masonry walls): - ...
  • Page 13: Section Nine Preparing The Appliance For Installation

    PARAGON FOCUS RS PLUS Installation Instructions SECTION EIGHT Siting the Appliance Continued *To minimise the risk of cracking due to heat expansion the use of a 3 – piece back panel is recommended*  The back panel of the surround must have a cut-out within the maximum and minimum dimensions as shown.
  • Page 14: Section Ten Install The Appliance

    PARAGON FOCUS RS PLUS Installation Instructions SECTION TEN To Install the Appliance INSTALLING THE APPLIANCE INTO CAVITY WALL ( When installing in a timber framed dwelling reference must be made to the specific installation requirements stated later in this Section ‘Installing The Appliance In Timber Framed Dwelling’).
  • Page 15: Installing The Appliance Into A Deep Rebated Surround Or Dummy Breast

    PARAGON FOCUS RS PLUS Installation Instructions SECTION TEN To Install the Appliance Continued  Increase both the recorded distances by 15mm each, and cut two lengths from the 100mm diameter pipe.  Remove the appliance from the opening, and position the gas supply (see connecting the gas supply later in this manual), taking account of the relative gas regulations appertaining to a gas pipe in a cavity.
  • Page 16 PARAGON FOCUS RS PLUS Installation Instructions SECTION TEN To Install the Appliance Continued  Using 125mm (5”) core drill, cut two holes following the pilot holes, drill from the outside of the dwelling through to the cavity, and from the inside through to the cavity ...
  • Page 17: Installing The Appliance Into A Timber Framed Dwelling

    PARAGON FOCUS RS PLUS Installation Instructions SECTION TEN To Install the Appliance Continued TIMBER FRAMED DWELLING This method allows for installation in timber frame buildings. Where removal of any part of the inner timber leaf of the wall is involved the structural integrity of the wall must be maintained and the advice of your local Building Control Department should be sought.
  • Page 18: Connecting The Gas Supply

    PARAGON FOCUS RS PLUS Installation Instructions SECTION TEN To Install the Appliance Continued TIMBER FRAMED DWELLING CONTINUED  The vapour barrier on the back of the inner timber leaf should be carefully cut and fixed to prevent ingress of damp into the plasterboard layer. NOTE: Neither the appliance nor the “Rockwool”...
  • Page 19: Section Twelve Check Operation Of Fire

    PARAGON FOCUS RS PLUS Installation Instructions SECTION TWELVE Check Operation of Fire CHECK BURNER PRESSURE AND GENERAL OPERATION  Remove the screw from the pressure test point on the burner inlet elbow and fit a pressure test gauge.  Turn on the gas to the appliance. Purge the air from the appliance by rotating the control to the ignition position, push in to allow the air in the pipe work to be purged and the piezo to ignite the pilot.
  • Page 20: Maintenance Instructions

    PARAGON FOCUS RS PLUS Maintenance Instructions SECTION FOURTEEN Maintenance Instructions General  Servicing should be carried out annually by a competent person such as a GAS SAFE - registered person in accordance with the relevant regulations, to ensure the safe and correct operation of the appliance.
  • Page 21: Replacement Of The Micro Switch

    4. Clean or replace in reverse order, and re- commission. When ordering parts quote 'PARAGON FOCUS RS PLUS' and the serial number of the fire, which can be found on the data badge which is located on the appliance remove decorative trim for access. Paragon Fires Telford Shropshire...
  • Page 22 Paragon Fires PARAGON FOCUS RS PLUS THIS IS YOUR EXTENDED FIVE YEAR PARTS WARRANTY PLEASE READ IT CAREFULLY AND ENSURE YOUR INSTALLER HAS FILLED IN THE FIRST PORTION, KEEP IT IN A SAFE PLACE SO THAT IT IS AVAILABLE GAS SAFE WHEN YOUR ENGINEER CARRIES OUT THE ANNUAL SERVICE.
  • Page 23 WARRANTY COVER Important For future reference we suggest you record the following details here, and keep the receipt as proof of purchase. This information may be asked for when you contact the helpdesk. Model: PARAGON FOCUS RS PLUS Serial No. This information can be found on the label attached to the packaging and on the data badge, which is located on the appliance remove decorative front for access.
  • Page 24 Date of Fourth annual service: Engineer Name Gas Safe Registration No. We may introduce modifications to products from time to time, and consequently the details given in this booklet are subject to alteration without notice. Paragon Fires Telford Shropshire TF3 3AR Telephone 0845 5195991 Web Site www.paragonfires.co.uk...
  • Page 25 LT5944 Iss 1 (25/10/11)
  • Page 26 PLEASE REGISTER YOUR 12 MONTH WARRANTY WITH US TODAY Simply detach this sheet from this booklet, complete and return it in a stamped addressed envelope to: PARAGON FIRES Charlton and Jenrick Ltd UNIT D STAFFORD PARK 2 TELFORD SHROPSHIRE TF3 3AR...
  • Page 27 LT5944 Iss 1 (25/10/11)
  • Page 28 Paragon RS PLUS L.P.G Focus A-0286 Product Serial No ID Label Prefix Data Badge Burner Tray / Box Assembly Air Test Completed Microswitch Check Warning Label (Fire Guard) Nut Spinner Installation Seal (2090) Restrictor Elbow (2189) Magnets (4 x 3048) Glass Panel Canopy (4540) Flue Assembly...

This manual is also suitable for:

Focus rs plus

Table of Contents