PARAGON FIRES
PARAGON FOCUS RS PLUS
REMOTE
ROOM SEALED INSET LIVE FUEL EFFECT GAS FIRE
OWNER'S
MANUAL
Please read these instructions carefully before you start
using the appliance
Keep this booklet handy for future reference
This appliance is
for use in GREAT BRITAIN or
IRELAND only
(2 x INJECTOR TIPS SUPPLIED WITH THIS APPLIANCE)
5.4kw – 2.4kw INJECTOR
&
3.8kw – 2.4kw INJECTOR
TELFORD
SHROPSHIRE
ENGLAND

Advertisement

Table of Contents
loading

Summary of Contents for Paragon Fires focus rs plus remote

  • Page 1 PARAGON FIRES PARAGON FOCUS RS PLUS REMOTE ROOM SEALED INSET LIVE FUEL EFFECT GAS FIRE OWNER'S MANUAL Please read these instructions carefully before you start using the appliance Keep this booklet handy for future reference This appliance is for use in GREAT BRITAIN or...
  • Page 2: Table Of Contents

    PARAGON FOCUS RS PLUS REMOTE Instructions CONTENTS PAGE User’s Instructions SECTION ONE Important Information Consumer Protection Health and Safety Notice SECTION TWO Introduction SECTION THREE Operation Lighting the Fire Turning Off the Fire SECTION FOUR Cleaning and Coal Laying Cleaning Decorative Trim...
  • Page 3: Paragon Focus Rs Plus Remote

    The PARAGON FOCUS RS PLUS REMOTE is an inset room sealed decorative fuel-effect gas appliance.  The PARAGON FOCUS RS PLUS REMOTE is available in Natural Gas (G20 @ 20 mbar) Only. The marking (G20 for natural gas) on the packaging and the data badge specify the gas for which the appliance has been factory set.
  • Page 4  The slot located at the top of the PARAGON FOCUS RS PLUS REMOTE are the hot air outlets and as such must not be obstructed in any way (particularly by clothes or other combustibles). In addition the base of the appliance should not be obstructed by such items as this may adversely affect the performance of the appliance.
  • Page 5: Section Two Introduction

    Introduction  The PARAGON FOCUS RS PLUS REMOTE is an inset room sealed live fuel-effect gas appliance designed for use in locations that do not have a conventional chimney. The appliance must be installed against an outside wall because the air to support combustion is taken from the outside and the products of combustion are expelled to the outside.
  • Page 6: Section Three Operation

    PARAGON FOCUS RS PLUS REMOTE Users Instructions SECTION THREE Operating the Appliance Do not use this appliance without the glass panel fitted, or if this panel is cracked or broken. WARNING: If the burner or pilot is extinguished for any reason, do not attempt to re-light the pilot for at least three minutes.
  • Page 7 PARAGON FOCUS RS PLUS REMOTE Users Instructions SECTION THREE Operating the Appliance Continued Low Battery Indication (Appliance) If you hear a repeated ‘bleep’ sound come from the appliance this indicates the appliance battery pack is low and should be changed as soon as possible. The appliance will continue to work normally for a short period but if the warning is ignored you may experience difficulty lighting the appliance or the appliance may automatically switch off for no apparent reason.
  • Page 8: Section Four Cleaning And Coal Laying

    PARAGON FOCUS RS PLUS REMOTE Users Instructions SECTION FOUR Cleaning & Fuel Bed Laying Warning: -Before you clean any part of the appliance ensure that the appliance is switched off and cool. CLEANING: DECORATIVE TRIM  The Decorative finish of the trim is coated with a high temperature lacquer, it should be wiped with a soft, clean, dry, cloth only.
  • Page 9: Cleaning And Replacing Coals

    PARAGON FOCUS RS PLUS REMOTE Users Instructions SECTION FOUR Cleaning & Fuel Bed Laying Continued Note: - If the fuel bed has not been placed correctly, causing the gas flame to contact the glass this may result in glass staining that cannot be removed by cleaning.
  • Page 10 PARAGON FOCUS RS PLUS REMOTE Users Instructions SECTION FOUR Cleaning & Fuel Bed Laying Continued COAL BED LAYOUT  The Coal set as shown consists of: Rear Matrix Front Matrix 10 x Individual Coals  The Front Matrix is located as shown in front of the burner ...
  • Page 11: Users Instructions

    Users Instructions PARAGON FOCUS RS PLUS REMOTE SECTION FOUR Cleaning & Fuel Bed Laying Continued  Insert back row of 4 coals as shown.  Complete front row of 6 coals as shown.  That completes the coal bed assembly ...
  • Page 12 Users Instructions PARAGON FOCUS RS PLUS REMOTE SECTION FOUR Cleaning & Fuel Bed Laying Continued The Pebble set as shown consists of: Front Matrix Rear Matrix 3 x ”A” Pebbles 6 x “B” Pebbles  The Front Matrix is located as shown in front of the burner ...
  • Page 13: Section Five Replacement Parts

    User Instructions PARAGON FOCUS RS PLUS REMOTE SECTION FOUR Cleaning & Fuel Bed Laying Continued  Finally position the remaining 4 ”B” shape pebbles as shown.  That completes pebbles assembly  Go to section eleven to complete the appliance assembly ...
  • Page 14: Installation Instructions

    Installation Instructions PARAGON FOCUS RS PLUS REMOTE SECTION SIX Appliance Data Wall Cut-out dimensions: Height 553mm Width 405mm Overall dimensions: Height 601mm Width 501mm Forward Projection: 90mm, (From fireplace opening Including typical fret.) Weight: 38.5kg (Boxed excluding fret) 37kg (Unboxed excluding fret)
  • Page 15: Section Seven Regulations And Warnings

    Installation Instructions PARAGON FOCUS RS PLUS REMOTE SECTION SEVEN Regulations and Warnings  This appliance must only be installed in Great Britain or Ireland.  The appliance is available in natural gas only.  Confirm that the appliance is suitable prior to installation (g20 for natural gas) (refer to data badge on base of appliance).
  • Page 16: Section Eight Siting The Appliance

    Installation Instructions PARAGON FOCUS RS PLUS REMOTE SECTION EIGHT Siting the Appliance (When installing in a timber framed dwelling reference must be made to the specific installation requirements stated in Section 10 Installing the Appliance in Timber Framed Dwelling). THERE ARE TWO TYPES OF INSTALLATION (into conventional masonry walls): - ...
  • Page 17: Section Nine Preparing The Appliance For Installation

    Installation Instructions PARAGON FOCUS RS PLUS REMOTE SECTION EIGHT Siting the Appliance Continued *To minimise the risk of cracking due to heat expansion the use of a 3 – piece back panel is recommended*  The back panel of the surround must have a cut-out within the maximum and minimum dimensions as shown.
  • Page 18: Section Ten Install The Appliance

    Installation Instructions PARAGON FOCUS RS PLUS REMOTE SECTION TEN To Install the Appliance INSTALLING THE APPLIANCE INTO CAVITY WALL ( When installing in a timber framed dwelling reference must be made to the specific installation requirements stated later in this Section ‘Installing The Appliance In Timber Framed Dwelling’).
  • Page 19 Installation Instructions PARAGON FOCUS RS PLUS REMOTE SECTION TEN To Install the Appliance Continued  Increase both the recorded distances by 15mm each, and cut two lengths from the 100mm diameter pipe.  Remove the appliance from the opening, and position the gas supply (see connecting the gas supply later in this manual), taking account of the relative gas regulations appertaining to a gas pipe in a cavity.
  • Page 20: Installing The Appliance Into A Deep Rebated Surround Or Dummy Breast

    PARAGON FOCUS RS PLUS REMOTE Installation Instructions SECTION TEN To Install the Appliance Continued INSTALLING THE APPLIANCE INTO DEEP REBATED FIRE SURROUND OR DUMMY CHIMNEY BREST. Additional duct pipe/s will be required. ( When installing in a timber framed dwelling reference must be made to the specific installation requirements stated later in this Section ‘Installing The Appliance In Timber Framed Dwelling’).
  • Page 21 SECTION TEN To Install the Appliance Continued  appliance top and side if it is fitted into a dummy chimneybreast, and fill any space between the appliance and the outside wall.  Position and seal the pipes two their respective spigots on the rear of the appliance (use flue seal or fire cement to ensure airtight seal, it must not obstruct the flue).
  • Page 22: Installing The Appliance Into A Timber Framed Dwelling

    PARAGON FOCUS RS PLUS REMOTE Installation Instructions SECTION TEN To Install the Appliance Continued TIMBER FRAMED DWELLING This method allows for installation in timber frame buildings. Where removal of any part of the inner timber leaf of the wall is involved the structural integrity of the wall must be maintained and the advice of your local Building Control Department should be sought.
  • Page 23: Connecting The Gas Supply

    PARAGON FOCUS RS PLUS REMOTE Installation Instructions SECTION TEN To Install the Appliance Continued TIMBER FRAMED DWELLING CONTINUED  The vapour barrier on the back of the inner timber leaf should be carefully cut and fixed to prevent ingress of damp into the plasterboard layer.
  • Page 24: Section Eleven Assemble The Appliance

    PARAGON FOCUS RS PLUS REMOTE Installation Instructions SECTION ELEVEN Assemble the Appliance  Position the refractory fuel bed components as described in section four of this manual, it is important that the fuel bed is positioned exactly as described to ensure the correct operation of the appliance.
  • Page 25: Section Twelve Check Operation Of Fire

    PARAGON FOCUS RS PLUS REMOTE Installation Instructions SECTION TWELVE Check Operation of Fire CHECK BURNER PRESSURE AND GENERAL OPERATION  Remove the screw from the pressure test point on the burner inlet elbow and fit a pressure test gauge. ...
  • Page 26: Maintenance Instructions

    PARAGON FOCUS RS PLUS REMOTE Maintenance Instructions SECTION FOURTEEN Maintenance Instructions General  Servicing should be carried out annually by a competent person such as a Gas Safe-registered person in accordance with the relevant regulations, to ensure the safe and correct operation of the appliance.
  • Page 27: Replacement Of The Thermocouple

    Turn on the gas supply, check for gas soundness and re-commission appliance. When ordering parts quote 'PARAGON FOCUS RS PLUS REMOTE and the serial number of the fire, which can be found on the data badge located behind the ash pan cover. (Refer to cleaning instructions for trim removal.)
  • Page 28 Paragon Fires PARAGON FOCUS RS PLUS REMOTE THIS IS YOUR EXTENDED FIVE YEAR PARTS WARRANTY PLEASE READ IT CAREFULLY AND ENSURE YOUR INSTALLER HAS FILLED IN THE FIRST PORTION, KEEP IT IN A SAFE PLACE SO THAT IT IS AVAILABLE...
  • Page 29: Service Log

    Date of Fourth annual service: Engineer Name Gas Safe Registration No. We may introduce modifications to products from time to time, and consequently the details given in this booklet are subject to alteration without notice. Paragon Fires Telford Shropshire TF3 3AR Telephone 0845 5195991 Web Site www.paragonfires.co.uk...
  • Page 30 LT5943 Iss 3 (02/12)
  • Page 31 Post Code TELEPHONE No. PRODUCT DETAILS Model: PARAGON FOCUS RS PLUS REMOTE Serial No. Date of Purchase This information can be found on the label attached to the packaging and on the data badge, which is located on the appliance, remove decorative front for access.
  • Page 32 Paragon Focus RS Plus Remote Coal Product Serial No A-0285 ID Label Prefix Data Badge Burner Tray / Box Assembly Air Test Completed Warning Label (Fire Guard) High Rate Injector Tip 1 x 360 (5867) Low Rate Injector Tip 1 x 220 (5868)