Cercon Clean 230VAC Instructions For Use Manual

Cercon Clean 230VAC Instructions For Use Manual

Single-user vacuum cleaner unit

Advertisement

Quick Links

Instructions for Use

Designation of the unit: Single-user vacuum-cleaner unit
Unit type:
CERCON CLEAN 230VAC
Unit No.:
_____________________

Advertisement

Table of Contents
loading

Summary of Contents for Cercon Clean 230VAC

  • Page 1: Instructions For Use

    Instructions for Use Designation of the unit: Single-user vacuum-cleaner unit Unit type: CERCON CLEAN 230VAC Unit No.: _____________________...
  • Page 2: Table Of Contents

    2/15 Dear Customer: Thank you for the confidence in our work that you showed us by buying this vacuum- cleaner unit. In order for you be able to enjoy your unit and its capabilities for many years, please take the time to read these Instructions for Use carefully, especially before using the unit for the first time.
  • Page 3: Safety

    Safety 1.1 Proper use The CERCON CLEAN single-user vacuum-cleaning unit is used in dental laboratories for the removal of the dust generated when working with dust- producing machinery. It is not permitted to attempt to use this unit for the removal of liquids.
  • Page 4: Conventions Used For The Safety Instructions In These Instructions For Use

    The vacuum-cleaning unit can be operated on any voltage between 200 and 240 V without any effect on the preset input air volume. The CERCON CLEAN is used as a vacuum accessory for dental milling units. The vacuum function is turned on automatically as soon as the milling unit is activated.
  • Page 5 5/15 dust collected. The large-area ultra-fine filter downstream from the single- use filter bag is capable of holding back Category C dust Fig. 1: View from front left Casing Cover Clamp locks (2 ea.) Panel Mounting cover Thumb screws (2 ea.) Connection socket for control cable Primary power socket (230 V/50 Hz) Air outlet...
  • Page 6: Turning On The Unit

    6/15 Fig. 2: Section through unit, viewed from the left Plastic connector for filter bag Sealing surfaces, circumferential Filter bag Seal, circumferential Basket Air intake opening Duct, 63 mm in diameter Air intake chamber Duct, 40 mm in diameter M6 nuts (2 ea.) Cover for filter bag Ledge with longitudinal bores Pre-filtration chamber...
  • Page 7: Electrically Connecting The Unit

    3.1 Checking the filtration module (see Figs. 1 and 2 on page 4) Caution The CERCON CLEAN single-user vacuum-cleaning unit must not be operated without an ultra-fine filter (31) and a filter bag (11), both correctly installed and undamaged. Open the two clamp locks (3) and remove the cover (2).
  • Page 8: Automatic Turn-Off And Filter Change Indicator

    8/15 Thanks to the built-on power stabilizer, the preset input air volume is kept constant as the mains voltage changes (between 180 and 264 V). 3.3 Automatic turn-off and filter change indicator (see Fig. 6 on page 9). Note As soon as the filter bags (11) has been filled to the maximum permissible, an underpressure switch will actuate the automatic turn-off function, and the filter change indicator on the milling unit will be lit.
  • Page 9: Inserting The Filter Bag

    9/15 Fig. 4: Removing the filter bag Caution The single-use filter bags must never be emptied and reused. Not only might this constitute a health hazard, but it would also impair the function of the unit. Caution Do not use pressurized air to remove any dust present in the filtration chamber (20).
  • Page 10: Cleaning (Replacing) The Ultra-Fine Filter

    10/15 Fig. 5. Inserting the filter bag Slide the new filter bag (11) in its basket (12) into the unit. The duct of the filter bag (10) will engage the duct (15) inside the filtration chamber (20) tightly. Slide the plastic connector (10) tightly onto the housing duct (15) of the vacuum unit.
  • Page 11: Service" Indicator

    If the “Service” indicator is lit, the vacuum motor (23) needs replacing. The vacuum motors must be checked – and if necessary replaced – by a specialist. Note Follow the “CERCON CLEAN single-user vacuum-cleaner unit troubleshooting checklist” during all maintenance and service work.
  • Page 12: Electrical Protection

    12/15 Electrical protection The entire unit is electrically protected using two fine-wire fuses (main fuse) 6.3 A/T. The two fuses are located in the fuse drawer (40) inserted in the primary power socket housing (8) ist. Fig. 7: Electrical protection Control cable socket Frequency selector 50/60 Hz Primary power socket...
  • Page 13: Technical Specifications

    13/15 Technical specifications Designation of the unit Single-user vacuum-cleaning unit Unit type CERCON CLEAN 230VAC Dimensions 420 mm wide (including mains cable relief), 390 mm deep (with vacuum duct), 540 mm high Voltage 200 + 240 Volt (50/60 Hz) Overvoltage category Max.
  • Page 14: Eu Declaration Of Conformity

    (inserted in the front of these Instructions for Use) by fax or mail. Fax +49 7181 73139 Designation of the unit Single-user vacuum -cleaner unit Unit type Duplicate CERCON CLEAN 230 VAC Unit No. Warranty Slip Date of purchase Reseller/depot DeguDent GmbH Rodenbacher Chaussee 4...
  • Page 15 15/15 EC Directive for Electrical Equipment Designed for Use Within Certain Voltage Limits (Low Voltage Directive) 73/23/EEC EC Electromagnetic Compatibility Directive 89/336/EEC The following harmonized standards were applied: DIN EN 292 Sicherheit von Maschinen. DIN EN 61 010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use DIN EN 55 014 Funk-Entstörung von elektrischen Betriebsmitteln und Anlagen.