In the interest of improving internal design, operational function, and/or reliability, NETSYS reserves the right to make changes to the products described in this document without notice. NETSYS does not assume any liability that may occur due to the use or application of the product(s) or circuit layout(s) described herein.
Factory, MRT, Train station, Ticket vending machine, Parking system, Monitoring system and point to point applications. Caution: The NV-600LI/RI is for indoor applications only. It can be used in industrial-grade applications. This product does not have waterproof protection, please do not used in outdoor applications.
Use ONLY the dedicated power supply for your device. Connect the power to the right supply voltage (110V AC used for North America and 230V AC used for Europe. NV-600LI/RI supports 12 to 48 VDC dual power input (Redundant power)).
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 CHAPTER 1. UNPACKING INFORMATION 1.1 Check List Carefully unpack the package and check its contents against the checklist. Package Contents: 1 x Industrial VDSL2 CO or 1 x QR code for user’s...
Installing the Router 2.1 Hardware Installation This chapter describes how to install the router and establish the network connections. The NV-600LI/RI may be installed on any level surface (e.g. a table or shelf). However, please take note of the following minimum site requirements before you begin 2.2 Pre-installation Requirements...
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 2.3 General Rules Before making any connections to the router, please note the following rules: • Ethernet Port (RJ-45) All network connections to the router Ethernet port must be made using Category 5 UTP/STP or above for 100Mbps, Category 3, 4 UTP for 10Mbps.
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 2.4 Connecting the Router The router has four Ethernet port which support connection to Ethernet operation. The devices attached to these ports must support auto-negotiation or 10Base-T or 100Base-TX unless they will always operate at half duplex. Use any of the Ethernet ports to connect to devices such as Monitor system, Server, Switch, bridge or router.
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 2.5 Terminal Block and DIN-Rail mount installation This section describes how to install the Terminal Block and DIN-Rail to the router, if you do not install the DIN-Rail, please paste the 4 rubber feet at the bottom of the hulled to avoid scratches of metal housing.
2.6 Connecting the RJ-11 / RJ-45 Ports The line port has 2 connectors: RJ-11 and terminal block. It is used to connect from NV-600LI(CO) using single pair phone cable to NV-600RI(CPE) bridge side (point to point solution). Take note that NV-600 line port cannot be used at the same time. Either...
Page 16
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Notes: Be sure each twisted-pair cable (RJ-45 ethernet cable) does not exceed 100 meters (333 feet). We advise using Category 5~7 UTP/STP cables for making Bridge or Router connections to avoid any confusion or inconvenience in the future when you attach high bandwidth devices.
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 2.7 Industrial VDSL2 router Application The router’s line port supports 100Mbps/0.3km for data service across existing phone wiring. It is easy-to-use which do not require installation of additional wiring. Every modular phone jack in the home can become a port on the LAN. Networking devices can be...
Page 19
2.7.1 Connect the NV-600LI and the NV-600RI to the Line The objective for VDSL2 is to pass high speed data over a twisted pair cable. In the setup, connects NV-600LI to NV-600RI through phone wire(24~26 AWG) or line simulator or any other hardware representation of a cable network, with or without noise injection and crosstalk simulations.
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Chapter 3. Hardware Description This section describes the important parts of the router. It features the front panel, side panel and rear panel. NV-600LI Outward NV-600RI Outward...
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 3.1 Front Panel The front panel provides a simple interface monitoring of the router. The figure shows the front panel. (Figure 3.1) Figure 3.1 Front panels (NV-600LI / NV-600RI)
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 3.2 Front Indicators The router has LED indicators. The following Table shows the description. (Table 3-3) Table 3-3 LED Indicators Description and Operation Color Status Descriptions On(Steady) Lights to indicate that the VDSL2 router had power...
Wiring the dual Power Inputs The NV-600LI/RI has two sets of power inputs, power 1 and power 2, which are located on the NV-600I’s side panel. Power 1 pins are the bottom two contacts of the upper 6-contact terminal block and power 2 pins are the only two contacts on the lower 2-contact...
Page 25
Polarity Protection function automatically. DC power will not be able to directly through the machine. 2. Please note that if the DC power current exceeds 3A, NV-600LI/RI will enable Overload Current Protection function automatically. DC power will not be able to directly through the machine.
Page 26
1. State 1 always happens before state 2. 2. Protection means enable Reverse Polarity Protection function. 3. Please note that if use different DC voltage, higher voltage will feeding to NV-600LI or NV-600RI. 4. Please note warranty is void if exceed DC 48V.
Page 27
Wiring the Relay Contact The NV-600LI/RI has a set of relay outputs. The relay contact uses two of the terminal block’s contacts located on the NV-600’s side panel. Refer to the following table shows how to connect the wires to the terminal block connector. In this section, we illustrate the meaning of the two contacts used to connect the relay contact.
Page 28
NV-600LI/RI is designed to enhance EMS performance by grounding. NV-600LI/RI come with metal DIN-Rail brackets for grounding the switches. For optimal EMS performance, connection of the right of the NV-600LI/RI side panel ground lug to the grounding point. Before user installed power and device, please read and follow these essentials: Use separate paths to route wiring for power and devices.
Chapter 4. Configure the NV-600LI/RI via Web Browser The NV-600LI/RI provides a built-in HTML based management interface that allow user configure the NV-600LI/RI via Internet Browser. Best viewed using Chrome or Firefox browsers. In order to use the web browser configure the device, you may need to allow: •...
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 4.2 Select the Menu Level There is an easy Setup for end users at the setup of NV-600LI/RI with SYSTEM,WAN, LAN, NAT, FIREWALL, ROUTE, UPNP, VDSL2, SNMP for more detail configurations.
Page 32
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Figure 4.2.2 Select the Menu Level(NV-600RI)
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 4.3 Select “SYSTEM” Select the “SYSTEM”. The menu below will be used frequently. It includes the sub-menus of Administrator Setting、 System Time、Firmware Upgrade、Device Mode、System Status、Reboot、Reset System Out. A screen is displayed as shown in Figure 4.3...
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 4.3.1 Administrator Setting To add a user or change user’s password, click on the “Administrator Settings” link in the left navigation bar. A screen is displayed as shown in Figure 4.3.1.
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 4.3.2 System Time You can set System Time by connecting to a Simple Network Time Protocol (SNTP) server allows the Modem to synchronize the system clock to the global Internet. The synchronized clock in the Modem is used to record the security log and control client filtering.
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 4.3.3 Firmware Upgrade To update the system firmware, click on the “Firmware Upgrade” link in the left navigation bar. A screen is displayed as shown in Figure 4.3.3 Figure 4.3.3 Firmware Upgrade The screen contains the following detail: •...
Page 37
2. “2.4.20_mvl31-ADM5120” of kernel version means the CPU number of an IC. # 1647 means a serial number of records compiled firmware. The date means the date of the firmware is compiled. 3. Please note that NV-600LI and NV-600RI firmware is different, therefore you can not use the same firmware upgrade.
1. The default setting is in Switch (Bridge) mode, it is not necessary to change the setting in most of the case. In situations, which devices (e.g. PC, Server, VoIP) connected to CPE requires Router function. Hence, set the NV-600LI/RI on Router mode.
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 4.3.5 System Status To view system status, click on the “System Status” link in the left navigation bar. A screen is displayed as shown in Figure 4.3.5 Figure 4.3.5 System Status...
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 4.3.6 Reboot To reboot the unit, click on the “Reboot” link in the left navigation bar. A screen is displayed as shown in Figure 4.3.6 Figure 4.3.6 Reboot Click “Reboot” to restart the unit.
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 4.3.7 Reset System To reset system to default, click on the “Reset System” link in the left navigation bar. A screen is displayed as shown in Figure 4.3.6 Figure 4.3.7 Reset NV-600LI/RI Router Click Reset button to restart the system to default configuration.
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 4.4 Select “WAN” Select the “WAN”. The menu below includes the sub-menus of Dymanic Settings, PPPoE and DNS. A screen is displayed as shown in Figure 4.4. Figure 4.4 WAN type in the left navigator bar Note: Please select the WAN mode you need.
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 4.4.1 Dynamic IP To configure the WAN interface to dynamically obtain an IP Address, click on the “Dynamic IP” link in the left navigation bar. A screen is displayed as shown in Figure 4.4.1...
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 4.4.2 IP Settings To configure the WAN interface to use a Static IP Address, click on the “Static IP” link in the left navigation bar. A screen is displayed as shown in Figure 4.4.2...
Page 45
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Fields in IP Settings: Field Description IP Address assigned by your ISP Enter the IP Address of NV-600LI/RI. Subnet Mask Enter the Subnet Mask of NV-600LI/RI. ISP Gateway Address Enter the Gateway address of the NV-600LI/RI.
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 4.4.3 PPPoE To configure the WAN interface to use PPPoE, click on the “PPPoE” link in the left navigation bar. A screen is displayed as shown in Figure 4.4.3 Figure 4.4.3 PPPoE Configuration...
Page 47
If no packets are transmitted between LAN port and WAN port or between Maximum Idle Time NV-600LI/RI and WAN, the connection is disconnected after the 'Maximum idle time. If the Auto-reconnect check box is selected, the PPP connection is re-established if there is some data that is received from the upper layers to be transmitted on this link.
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 4.4.4 DNS To configure the DNS address, click on the “DNS” link in the left navigation bar. A screen is displayed as shown in Figure 4.4.4 Figure 4.4.4 DNS Configuration...
4.5 Select “LAN” The menu below will not be used very often, but when connecting the NV-600LI/RI to a new control PC, one may want to go through the following steps in order to make the IP address previously set by ifconfig in the console or on some later occasion one may want to change it again without using the console then the menu below will be helpful.
4.5.1 Select LAN Settings and set the IP Address The form below is used to change the IP address of the LAN port “adm0” in the NV-600LI/RI. The proposed IP address is either the default address of adm0 or it is the address changed by an ifconfig command via the shell running in the terminal.
Page 51
“APPLY” in order to make the displayed IP address new default address. Note: For the NV-600LI/RI it is recommended to select a simple IP setting suitable to controlled lab environments. Set a static IP address and don’t use DHCP. The screen contains the following details:...
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 DHCP Client List 4.5.2 The DHCP client list allows you to see which clients are connected to the VDSL2 CPE Modem via IP address, host name, and MAC address. To view the DHCP client list, click on the “DHCP Client List” link in the left navigation bar. A screen is displayed to list all DHCP client connection with IP Address and MAC Address as shown in Figure 4.5.2...
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 LAN Switch Port Setting 4.5.3 To view the All LAN Port Setting, click on the “Lan Switch Port Setting” link in the left navigation bar. A screen is displayed to all LAN Port Setting as shown in Figure 4.5.3...
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 LAN Port Status 4.5.4 To view the All LAN Port Status, click on the “Lan Port Status” link in the left navigation bar.The following information provides a view of the current Ethernet ports status of the unit. A screen is displayed to Status as shown in Figure 4.5.4...
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 4.6 Select “NAT” Network Address Translation(NAT) allows multiple users at your local site to access the internet through a single public IP address or multiple public IP address. NAT can also prevent hacker attacks by mapping local address to public address for key services such as the Web or FTP.
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Virtual Server 4.6.1 You can configure the Router as a virtual server so that remote users accessing services such as the Web or FTP at your local site via public IP addresses can be automatically redirected to local servers configured with private IP addresses. In other words, depending on the requested service (TCP/UDP port numbers), the Router redirects the external service request to the appropriate server (located at another internal IP address).
Page 57
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 The screen contains the following details: Fields in Virtual Server: Field Description Private IP Enter a private IP Address of specified entry. Private Port Enter a private Port number of the specified entry.
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Virtual Server 4.6.2 For some applications, you need to assign a set or a range of ports to a specified local machine to route the packets. Router allows the user to configure the needed port mappings to suit such applications.
Page 59
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 The screen contains the following details: Fields in Port Mapping: Field Description Server IP Enter the IP Address of a specified local machine. Mapping Port Assign a range of port or specific port number to route the packets.
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 4.6.3 If you have a local client PC that cannot run an Internet application properly from behind the NAT firewall, you can open the client up to unrestricted two-way Internet access by defining a virtual DMZ Host.
Page 61
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 The screen contains the following details: Fields in DMZ: Field Description Enable or disable the DMZ setting of NV-600LI/RI. Select the check box to enable this Enable option. IP Address Enter IP Address of the DMZ host.
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 4.7 Select “Firewall” The industrial-grade VDSL2 router provides extensive firewall protection by restricting connection parameters to limit the risk of instrusion and defending against a wide array of common hacker attacks. However, for applications the require unrestricted access to the internet, you can configure a specific client/server a demilitarized zone(DMZ).
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Firewall Options 4.7.1 "Block WAN Scan" allows you to prevent the hackers from testing the services of the VDSL2 CO Modem. "Discard ping from WAN side" cause the VDSL2 CO Modem not to respond to the hacker scan packets from the public WAN IP address.
Page 64
Select the check box to drop all PING from the WAN side. Discard PING the Gateway Select the check box to drop all PING to NV-600LI/RI packet for the LAN side. Drop Port Scan Select the check box to drop all the port scan packets.
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 4.7.2 Client Filtering To enable Client Filter, click on the “Client Filtering” link in the left navigation bar. A screen is displayed as shown in Figure 4.7.2. Figure 4.7.2 Client Filter Configuration...
Page 66
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 The screen contains the following details: Fields in Client Filter: Field Description Enable or disable the Client Filter feature of VDSL2 CO&CPE ROUTER. Select the Enable Client Filter check box to enable this option.
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 4.7.3 MAC Control You can block certain client PCs accessing the Internet based on MAC addresses. To configure MAC Control, click on the “MAC Control” link in the left navigation bar. A screen is displayed as shown in Figure 4.7.3...
Page 68
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 The screen contains the following details: Fields in MAC Control: Field Description MAC Address Control Enable or disable the MAC address control. Enable or disable block status. If the check box is selected, it blocks the Block Connection to Internet specified MAC address.
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 4.8 Select “Route” If there are multiple routers installed on your network, it is necessary to configure the VDSL2 router unit’s routing functions. Select the “Route”. The menu below includes the sub-menus of...
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 4.8.1 Static Routing The static routing function determines the path that data follows over your network before and after it passes through your router. You can use static routing to allow different IP domain users to access the Internet through this VDSL2 Router device.
Page 71
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 The screen contains the following details: Fields in Static Routing: Field Description Destination LAN IP Enter the IP Address 0-0-0-0 of routing entry. Subnet Mask Enter the Subnet Mask 0-0-0-0 of routing entry.
The Routing table allows you to see how many routings on your VDSL2 router routing table and interface information. To view the Routing entry table list of NV-600LI/RI, click on the “Routing Table List” link in the left navigation bar. A screen is...
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 4.9 Select “UPNP” UPnP is an architecture for pervasive peer-to-peer network connectivity of intelligent appliances, wireless devices, and PCs of all from factors. It is designed to bring easy-to-use, flexible, standards-based connectivity to ad-hoc or unmanaged networks whether in the home, in a small business, public spaces, or attached to the Internet.
Page 74
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 The screen contains the following details: Fields in UPnP Settings: Field Description To enable or disable UPnP Setting. Select the check box to Enable or Disable the UPnP Enable UPnP function of SPEED-VDSL2 CO&CPE ROUTER.
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 4.10 Select “SNMP” The SNMP Settings can be viewed in the left navigation bar. The following are the options available under SNMP, as shown in Figure 4.10 Figure 4.10 SNMP in Left Navigator Bar...
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 4.10.1 SNMP Setting To enable or disable the SNMP Settings, click on the “SNMP Setting” link in the left navigation bar. A screen is displayed as shown in Figure 4.10.1...
Page 77
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 The screen contains the following details: Fields in SNMP Settings: Field Description To enable or disable SNMP Setting. Select the check box to Enable or Disable the Enable SNMP SNMP function of NV-600LI/NV-600RI.
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 4.10.2 SNMPv3 Setting To enable or disable the SNMPv3 Settings, click on the “SNMPv3 Setup” link in the left navigation bar. A screen is displayed as shown in Figure 4.10.2...
Page 79
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 The screen contains the following details: Figure 4.10.2-1 SNMPv3 Setting(Disable) Fields in SNMPv3 Settings: A screen is displayed as shown in Figure 4.10.2-1. Field Description To enable or disable SNMP Setting. Select the check box to Enable or Disable the SNMP Enable SNMPv3 function of NV-600LS/NV-600RS.
Page 80
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Figure 4.10.2-2 Add a v3 user Fields in SNMPv3 Add Settings: A screen is displayed as shown in Figure 4.10.2-2. Field Description Select the check box to Read-Only or Read-Write.
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Chapter 5. Operating the VDSL2 System After the VDSL2 system has been set up, one may want to configure the settings that are related to VDSL2. Configuration of operation modes, test modes (loop back) and the display of status information are supported by GUI (Graphical User Interface).
Page 82
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 VDSL2 menu table list: Section Item Description Channel Config Configuration of line per bearer basis. Line Config Configuration of line. Profile Config Configuration of line for specific band plans.
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 5.1 Select “Channel Config” To config the VDSL2 channel, click on the “Channel Config” link in the left navigation bar. A screen is displayed as shown in Figure Figure 5.1 Channel Configuration Menu...
Page 84
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Channel Configuration Settings: Setting Description To which bearer channel number shall the settings apply? Channel Number Channel 0 To which direction shall the settings apply? Direction Upstream Downstream Min Data Rate...
Page 85
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 The following description about interleave delay function: Interleave delay function is used in digital data transmission technology to protect the transmission against noise issue and data error. If during transit more than a certain amount of data has been lost then the data cannot be correctly decoded. Short bursts of noise on the line can cause these data packets to become corrupt and the router has to re-request data which in turn can slow down the overall rate at which data is transmitted.
Page 86
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 If your line is particularly susceptible to bursts of noise then interleaving should improve your VDSL2 experience simply because if you lose a whole batch of data then this could cause your router to loose sync with the exchange.
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 5.2 Select “Line Config” To config the Line, click on the “Line Config” link in the left navigation bar. A screen is displayed as shown in Figure 5.2 Figure 5.2 Line Configuration Menu for SNR Margin Selection...
Page 88
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Line Configuration Settings: Setting Description Direction Select the target direction. Target SNRM Set the required SNR Margin *10 (60=6dB) Note: Noise Margin is the non-technical term for Signal to Noise Ratio Margin (SNRM). Domestic standard modems and VDSL2 routers often use the terms Noise Margin or SNR when reporting on its value.
NV-600L. The only thing that NV-600R must be configured so that the routers will link is the tone mode. However, the default tone mode for NV-600LI/RI is V43, so at default there’s no need to change the tone mode unless it is required by the telecom companies to use different tone mode.
Page 90
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 To config the Profile, click on the “Profile Config” link in the left navigation bar. A screen is displayed as shown in Figure 5.3.1 & 5.3.2 Figure 5.3.1 NV-600LI Profile Configuration...
Page 91
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Figure 5.3.2 NV-600RI Profile Configuration • Click APPLY at any time during configuration to save the information that you have entered. • Click CANCEL to exit from this page without saving the changes.
Page 92
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Figure 5.3.3 Band Profile and Plan Setup Error Figure 7.1.3.4 Band Profile Region...
Page 93
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 The following shows the band profile and band plan compatibility: Band Profile List Band Plan List VDSL2 Profile8a Annex A M1_EU32 VDSL2 Profile8b Annex A M9_EU64 VDSL2 Profile8c Annex B 997-M2x-A (B05)
Page 94
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Band Profile \ Band Plan 13 14 16 18 20 21 22 23 24 25 26 Note: O = Compatible; X = Not Compatible Tip: Downstream: Traffic from Transmitter to Receiver...
Page 95
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Following examples for band profile and band plan combination, you can find minimum distance and maximum distance relationship. Please note that the following data represents test result in a lab environment and are for reference only, the actual data rate will vary on the quality of the copper wire and environment factors.
Page 96
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Band Minimum Distance Maximum Distance Band Plan Porfile Distance Upstream Downstream Distance Upstream Downstream 100 m 6.8 Mbps 85 Mbps 1800 m 0.1 Mbps 23.7 Mbps Annex B 998 M2x-A (B10) 100 m 7.7 Mbps...
Page 97
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Band Minimum Distance Maximum Distance Band Plan Porfile Distance Upstream Downstream Distance Upstream Downstream 100 m 51.9 Mbps 58.6 Mbps 2000 m 0.8 Mbps 8.1 Mbps Annex B 997 M2x-M (B06)
Page 98
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Band Minimum Distance Maximum Distance Band Plan Porfile Distance Upstream Downstream Distance Upstream Downstream 100 m 28.5 Mbps 100 Mbps 1400 m 1 Mbps 34.2 Mbps Annex B 998 M2x-M (B11) 100 m 28.3 Mbps...
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 5.4 Select “Loop Back” Loopback (loop-back) describes ways of routing electronic signals, digital data streams, or flows of items from their originating facility back to the source without intentional processing or modification. This is primarily a means of testing the transmission or transportation infrastructure.
Page 100
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 The screen contains the following details: Loop Back Setting Description To which bearer channel number shall the settings apply? Channel No. Channel 0 Loop System loop or line side loop...
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 5.5 Select “Activate Deactivate” This function is for enable/disable VDSL2 port. A screen is displayed as shown in Figure 5.5 Figure 5.5 Activation and Deactivation of the Line...
Page 102
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Line Activation/Deactivation: Setting Description Activate or deactivate the line. (Select the activity and the press the APPLY Line button.) • Click APPLY at any time during configuration to save the information that you have entered.
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 5.6 Select “Line Status” This function provides SNR value for checking phone wiring quality. A screen is displayed as shown in Figure 5.6 Figure 5.6 Line Status Display: Actual SNR Note: Band Actual SNR value, if the value is 0 dB, currently dose not transmit;...
Page 104
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 The following status messages may occur(Reference only): Line Status Description Line Status Description EXCHANGE for VDSL2 this is a substate of FULL_INIT not_initialized exchange Line Status is not initialized! and is not reported.
Page 105
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 device state FULL INIT. DISCOVERY for VDSL2 this is a discovery resync, test Resync test status substate of FULL INIT and is not reported. TRAINING for VDSL2 this is a substate of FULL...
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 5.7 Select “Channel Status” This function shows VDSL2 port status. A screen is displayed as shown in Figure 5.7 Figure 5.7 Channel Status Note: The channel status shows accurate value as data rate, CRC, INP...etc when link established. All values will vary on the quality of the...
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 5.8 Select “Version Info” This function shows VDSL2 hardware and firmware version. A screen is displayed as shown in Figure 5.8 Figure 5.8 Display of Version Data Note: If you would like to search web interface version, please refer to section 4.3.3.
5.9 Select “SNR Graphs” When NV-600LI link with NV-600RI, this graph will show the SNR value for each band. Shown power level in upstream and downstream spectrum, The higher the SNR value, the better the performance. A screen is displayed as shown in Figure 5.9.1 and...
Page 110
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Following graph shows the snr per tone expand graph, please press “Expand Graph” button to get the graph. A screen is displayed as shown in Figure 5.9.3 and Figure 5.9.4 Figure 5.9.3 NV-600LI snr per tone expand graph...
Page 111
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Following chart shows the snr per tone expand value, please press expand “Show Raw Values” button to get the chart. A screen is displayed as shown in Figure 5.9.5 and Figure 5.9.6 Figure 5.9.5 NV-600LI snr per tone chart...
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 5.10 Select “Bits Graphs” When NV-600LI link with NV-600RI, this graph will show the bits value for each tone. Shown tone length in upstream and downstream spectrum. A screen is displayed as shown in Figure 5.10...
Page 113
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Following graph shows the bits per tone expand graph, please press “Expand Graph” button” to get the graph. A screen is displayed as shown in Figure 5.10.2 Figure 5.10.2 snr per tone expand graph Following chart shows the bits per tone expand value, please press expand “Show Raw Values”...
Page 114
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Regarding the describe of "tone graph"(Only reference): "If slow service is indicated, technicians can look at the bits per tone measurement. Dips in the bit per tone graph indicate interference.
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Chapter 6. Configure the NV-600LI/RI via Console 6.1 Setup on Hyperterminal Open the Hyperterminal and set the baud rate to 115200, 8N1N to properly set the hyperterminal. Figure 6.1 Hyperterminal Configuration...
Page 116
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 If the VDSL2 Router has been powered up already you will see a prompt by hitting the ENTER key. A screen is displayed as shown in Figure 6.2 Figure 6.2 Command Line Note: As you may identify from the commands above Industrial VDSL2 Router is a Linux based device.
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 6.2 Check IP via CLI command At the CLI command, write the command “ifconfig” to show the VDSL2 ip of web ui. Following screen is the NV-600LI, the NV-600RI looks very similar. A screen is displayed as shown in Figure 6.3...
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 6.3 Reset the system to default configuration At the CLI command, write the command “rawaccess –e” to reset the system to default configuration. For it to take effect write the command “reboot”...
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Appendix A: Cable Requirements A.1 Ethernet Cable A CAT 3~7 UTP (unshielded twisted pair) cable is typically used to connect the Ethernet device to the router. A 10Base-T cable often consists of four pairs of wires, two of which are used for transmission. The connector at the end of the 10Base-T cable is referred to as an RJ-45 connector and it consists of eight pins.
Page 120
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Figure A-2 Pin Assignments and Wiring for an RJ-45 Straight-Through Cable Figure A-3 Pin Assignments and Wiring for an RJ-45 Crossover Cable...
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Appendix B: Product Specification Key Features & Benefits • Supports auto speed for Line port • Supports high bandwidth up to 100Mbps symmetric over line ports • Supports Web management (HTTP), TFTP •...
Page 122
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Product Specification IEEE802.3 / IEEE802.3u standard Standard: ITU-T G993.2 VDSL2 standard 4 * RJ-45 10/100Mbps auto-sensing Ethernet port 1 * RJ-11/Terminal Block connector for VDSL2 line port Physical Interface:...
Page 123
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 EMI Compliant: FCC Class A EMC: EMS Compliant: CE mark -20°C ~ 70°C (-4°F ~ 158°F) Fanless, free air cooling Operating Temperature: Storage Temperature: -40°C ~ 70°C (-40°F ~158°F)
2.4 Verify that the proper cable type is used and its length does not exceed specified limits. 2.5 Check the router on the attached device and cable connections for possible defects. 2.6 Make sure that the phone wire must be connecting NV-600LI/RI first, when powered on. 2.7 Replace the defective router or cable if necessary.
Page 125
3.1 Please make sure that the phone wire must be connected between NV-600LI(CO) and NV-600RI (CPE) when both are power on. NV-600LI (CO) will do link speed function depending on phone wire length, therefore if NV-600LI (CO) can’t detect NV-600RI (CPE) over phone wire Solution: while both power on, this will cause the link to fail.
Page 126
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 The protocol was standardized in the International Telecommunication Union telecommunications sector (ITU-T) as Recommendation G.993.2. It was announced as finalized on 27 May 2005,[1] and first published on 17 February 2006. Several corrections and amendments were published in 2007 through 2011.
Page 127
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 SNR is commonly quoted for electrical signals, it can be applied to any form of signal (such as isotope levels in an ice core or biochemical signaling between cells). The ratio is usually measured...
Page 128
VDSL2 CO/CPE mode correctly. Choose “1” if it is CO router and “0” if it is CPE router. Do not just press enter to skip the setting as it will not retain even if the setting is correct, then it will become unknown causing the VDSL2 router not to link. 1: NV-600LI. 0: NV-600RI. Solution: 2.
Page 129
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 System Diagnostics Power and Cooling Problems If the POWER indicator does not turn on when the power cord is plugged in, you may have a problem with the power outlet, power cord, or internal power supply as explained in the previous section.
Page 130
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Physical Configuration If problems occur after altering the network configuration, restore the original connections, and try to track the problem down by implementing the new changes, one step at a time. Ensure that cable distances and other physical aspects of the installation do not exceed recommendations.
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Appendix D: IP-30 protection of metal case The term “protection class” generally indicates the type of protection of a device or the internal workings of a device against direct contact and against the infiltration of foreign bodies, such as objects, dust or water.
Page 132
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Table D-2 Second Digit: Protection grades for water protection. Digit Designation Explanation No protection No special protection to prevent water infiltration. Protection against vertically dripping Water dripping vertically on to the device may not have any harmful effect.
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Appendix E: Compliance Information FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a computing device, pursuant to Part 15 of FCC rules.
Page 134
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 proper functioning of your equipment. If they do, you will be notified in advance in order for you to make necessary modifications to maintain uninterrupted service. This equipment may not be used on coin service provided by the telephone company. Connection to party lines is subject to state tariffs.
Page 135
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 WEEE Warning To avoid the potential effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment, end users of electrical and electronic equipment should understand the meaning of the crossed-out wheeled bin symbol.
NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4 Warranty The original owner that the product delivered in this package will be free from defects in material and workmanship for one year parts after purchase. There will be a minimal charge to replace consumable components, such as fuses, power transformers, and mechanical cooling devices.
Need help?
Do you have a question about the NV-600LI and is the answer not in the manual?
Questions and answers