INSTALLER: Leave this manual with party responsible for use and operation.
OwNER: Retain this manual for future reference.
NOTICE: SAVE THESE INSTRUCTIONS
Model(s):
PF-120 Pellet Furnace
!
Tested and approved for wood pellet fuel only. Burning
of any other type of fuel voids your warranty.
!
Check building codes prior to installation.
• Installation MUST comply with local, regional, state
and national codes and regulations.
• Contact local building or fire officials about restrictions
and installation inspection requirements in your area.
1
Installation Manual
Installation and Appliance Setup
CAUTION
CAUTION
Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14
!
Please read this entire manual before
installation and use of this pellet fuel-
burning room heater.
Failure to follow these instructions could
result in property damage, bodily injury
or even death.
• Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
• Do not overfire - If any external part starts to glow, you
are overfiring. Reduce feed rate. Overfiring will void
your warranty.
• Comply with all minimum clearances to combustibles
as specified. Failure to comply may cause house fire.
!
HOT SURFACES!
Glass and other surfaces are hot during
operation and cool down.
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
stove.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other
flammable materials.
• Keep clothing, furniture, draperies and other flammable
materials away.
NOTE
To obtain a French translation of this manual, please
contact your dealer or visit www.harmanstoves.com
Pour obtenir une traduction française de ce manuel, s'il
vous plaît contacter votre revendeur ou visitez www.
harmanstoves.com
WARNING
WARNING
3-90-08121i

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PF-120 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Harman PF-120

  • Page 1 To obtain a French translation of this manual, please Check building codes prior to installation. contact your dealer or visit www.harmanstoves.com • Installation MUST comply with local, regional, state and national codes and regulations. Pour obtenir une traduction française de ce manuel, s’il • Contact local building or fire officials about restrictions vous plaît contacter votre revendeur ou visitez www. and installation inspection requirements in your area. harmanstoves.com Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14 3-90-08121i...
  • Page 2: Table Of Contents

    H. Outside Air Installation ......16 Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14 3-90-08121i...
  • Page 3: Installation Standard Work Checklist

    Verified all clearances meet installation manual requirements. ________________________________ Appliance Setup Section 5 (Pg. 20-21) All packaging and protective materials are removed ________________________________ Accessories installed properly ________________________________ Manual bag and all it’s contents are removed from inside the appliance and given to party responsible for use and operation ________________________________ Started appliance and verified that all motors and blowers operate as they should. ________________________________ Hearth and Home Technologies recommends the following: Photographing the installation and copying this checklist for you file. The this checklist remain visible at all times on the appliance until the installation is complete. Comments: Further description of the issues, who is responsible (Installer/Builder/Other Trades, etc.) and corrective action needed __________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ Comments communicated to party responsible____________________ by ________________________ on __________ (Builder / Gen Contractor) (Installer) (Date) Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14 3-90-08121i...
  • Page 4: Product Specific And Important Safety Information

    NOTE: Hearth & Home Technologies, manufacturer of combustion air inlet is provided. this appliance, reserves the right to alter its products, their specifications and/or price without notice. The structural integrity of the mobile home floor, ceiling, and walls must be maintained. The appliance must be properly grounded to the frame of the mobile home and use only listed Harman® is a registered trademark of Hearth & Home pellet vent, Class “PL” connector pipe. Technologies. A Harman® Outside Air Kit must be installed in a mobile home installation. Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14 3-90-08121i...
  • Page 5: Getting Started

    • Installation and use of any damaged appliance or vent system component. • Modification of the appliance or vent system. • Installation other than as instructed by Hearth & Home Technologies. • Installation and/or use of any component part not approved by Hearth & Home Technologies. Any such action may cause a fire hazard. Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14 3-90-08121i...
  • Page 6: Clearances

    Clearances A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. 62.474 37.961 20.220 WITHOUT BLOWER BOX INSTALLED 44.478 4.060" I.D. 4.188" O.D. 27.238 16.802 25.254 22.035 3.215 3.215 26.014 24.965 Figure 3.1 Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14 3-90-08121i...
  • Page 7: Clearances To Combustibles

    24” temperature of the discharge air MUST be taken into consideration (The discharge air temperature may be high enough to cause burns if not properly operated and maintained.) CAUTION The Blower Motor full load AMPS 1” MUST be checked. A plenum damper may be required to adjust the motor 1” full load AMPS to the motor nameplate rating. Figure 3.3 Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14 3-90-08121i...
  • Page 8: Floor Protection

    C. Floor Protection The shaded area indicates the required floor protection area. The furnace requires 48” x 52” of floor protection centered around the skid plate footprint. Flooring should be a minimum of 26 gauge sheet metal covering the installation clearance area and 18” in front of, and 8” to either side of the ash pan door. Fig 3.4 Minimum Size floor protection is 48" X 52". Only needed when installed on a combustible floor. Floor protection dimensions for the front and sides are measured from the appliance door opening in The United States. Floor Protection Requirements Sides 8" Front 18" 8” 18” Door opening 8” side of the furnace Figure 3.4 Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14 3-90-08121i...
  • Page 9: Termination Location And Vent Information

    Any exterior venting (vent pipe exposed to outside ambient temperatures) should be kept to a minimum, due to potential condensation problems. This is especially important in high humidity cold weather climates, such as maritime areas, lake shores, and low river valleys. Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14 3-90-08121i...
  • Page 10: Vent Configuration Graph

    • Vents should not terminate under overhangs, decks or the exhaust vent outlet. onto covered porches. when the appliance is roof vented: The air intake is best • Maintain minimum clearance of 12” from the vent located on the exterior wall oriented towards the prevailing termination to the exterior wall. wind direction, during the heating season. Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14 3-90-08121i...
  • Page 11: Locating Your Appliance And Chimney

    • Lower roof line • Avoid outside wall in cooler climates Windward Leeward Multi-level Roofs Recommended: NOT recommended: Outside Air Intake Outside Air Intake on windward side on leeward side Figure 4.3 Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14 3-90-08121i...
  • Page 12 Inside Corner Detail Fixed Porch or Deck Closed Openable Fixed Openable or Fixed Closed Openable Sidewalk =Vent Terminal =Air Supply Inlet =Area where termination is not permitted Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14 3-90-08121i...
  • Page 13 The chimney should be cleaned and or inspected before installation. Figure 4.7 36” Figure 4.5 Creosote - Formation and Need for Removal - When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow-burning fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote makes an extremely hot fire. The pellet vent pipe should be inspected at least twice monthly during the heating season to determine if a creosote buildup has occurred. If creosote has accumulated it should be removed to reduce the risk of a chimney fire. Guidance on minimizing creosote formation and the need for periodic creosote removal: The chimney should be inspected during the heating season to determine if a creosote build-up has occurred. If a significant layer of creosote has accumulated (3mm or more) it should be removed to reduce the risk of a chimney fire. Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14 3-90-08121i...
  • Page 14: Draft

    Causes include: is not achieved. For this reason and the fact that the PF-120 • Combustion air requirements for furnaces, water heaters operates with a positive vent pressure, we specify that the and other combustion appliances joints also be sealed with silicone. • Location of return-air vents to furnace or air conditioning Where passing through an exterior wall or roof, be sure to use the appropriate pass-through device providing an adequate • Imbalances of the HVAC air handling system vapor barrier. Venting manufacturers generally provide these • Upper level air leaks such as: pas-through devices. - Recessed lighting To minimize the effects of negative air pressure: • Install the outside air kit with the intake facing prevailing winds during the heating season • Ensure adequate outdoor air for all combustion appliances and exhaust equipment Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14 3-90-08121i...
  • Page 15: Fire Safety

    Damaged parts may impair safe home. operation. • Do NOT install damaged components. • Locate smoke detector away from the heating appliance and close to the sleeping areas. • Do NOT install incomplete components. • Follow the smoke detector manufacturer’s placement and • Do NOT install substitute components. installation instructions and maintain regularly. Report damaged parts to dealer. • Conveniently locate a Class A fire extinguisher to contend with small fires. • In the event of a hopper fire: • Evacuate the house immediately. • Notify fire department. Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14 3-90-08121i...
  • Page 16: Outside Air Installation

    Direct Vent Wall Pass-through Kit total house demand. House demand may consume some (Part #1-00-677177) air needed for the stove, especially during a power failure. It may be necessary to add additional ventilation to the space in which the pellet appliance is located. Consult with your local HVAC professional to determine the ventilation demands for your house. To install outside air use 3" non-combustible flex pipe Figure 4.8. There is a break-away hole on the rear panel of the PF- 120 stove which must be removed before connecting the flex pipe. The pipe should be run outside and terminate to the side or below the vent pipe outlet so the flue outlet is more than 12" from the inlet cover. The maximum length run of this pipe is 15 feet. The Inlet cover should be used to keep birds, rodents, etc. out of the pipe Figure 4.8. You may choose to use the optional Direct Vent Wall Pass- Figure 4.9 through Kit which incorporates the venting pass-through and outside air inlet into one component. Figure 4.9. Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14 3-90-08121i...
  • Page 17: Appliance Setup

    See Figure 5.1. Bottom 2. Place the desired vertical panel inside the bottom tray and hold into place with one Tek screw in the bottom middle hole. (solid panel shown) See Figure 5.1. Knockouts This Edge Toward Furnace Figure 5.1 Top (same as bottom) Blower access Panel Solid Side Panel Filter Frame Filter Blower access Panel Cover Bottom (same as top) Figure 5.2 Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14 3-90-08121i...
  • Page 18 NOTE: Do not put any screws into any of the top holes at this time. Figure 5.3 Figure 5.4 4. Place the remaining panel, (in this case the blower access Open Side Panel panel) in the bottom panel and into the corner of the solid panel Figure 5.5. Make sure that the panel is in the upright position. There are no cover mounting holes in the bottom edge of this panel. Hold the panel into place with one Tek screw in the middle hole of the solid panel and one in the bottom middle hole of the blower access panel. Figure 5.5 Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14 3-90-08121i...
  • Page 19 - Low (Note: the purple wire on the 1638 cfm blower is neutral, and gets spliced to the white neutral wire.) Access Panel Cover opening 8. Install the access panel cover by hooking the lip at the bottom of the cover over the edge in the filter box. Use 6 Tek screws to secure the access panel. Figure 5.7 Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14 3-90-08121i...
  • Page 20: Blower Assembly

    Figure 5.9 listed, a supply air restricting damper may be required to increase the supply plenum positive static pressure. 3. Mount the filter box on the furnace with (6) #10 x 3/4 Tek screws, 3 on each side Figure 5.10. Visually locate these holes so you are familiar with their location on the filter box and the furnace. Access to the mounting holes can be gained through the blower access panel cover and the filter opening. Figure 5.11. Note: Two pieces of 2x4 stacked laying flat on the floor 12 inches from the blower opening will support the filter box during installation Figure 5.10 Figure 5.11 Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14 3-90-08121i...
  • Page 21: Firebrick

    Follow the wiring instructions on the label alongside the terminal block Figure 5.14. Datacom Cable wall Control CAUTION Orange - Red (+ LED) With this small gauge of wire, care must be taken not to Blue/White- Blue (Tstat) over-tighten the terminal screws thus, breaking the wire. Orange/White- White or Blk (- LED) Blue- Blue (Tstat) Figure 5.14 FUEL Figure 5.13 Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14 3-90-08121i...
  • Page 22: Duct System Installation

    EXISTING UNIT PF100 Figure 5.15 Installing Duct The pellet furnace may be connected to a gas or oil-fired central furnace or heat pump duct system Figure 5.15. Prior to installation, determine whether all requirements for installation including all clearances can be met. Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14 3-90-08121i...
  • Page 23 The velocity to sound level must be taken into consideration It is highly recommended that the furnace when connecting this furnace into an existing duct system. control be turned to the “OFF” position when As a primary source furnace the duct system can be installed air conditioning is being used, whether or not to fit the customers needs. it is interconnected. Velocity 500fpm 700fpm 900fpm Static-In. W.C. .3 Minimum to .6 Maximum 1638 cfm 470 in² 360 in² 290 in² (These duct sizes are only recommendations.) The Return Air duct system should be sized approximately 10 percent larger for heating only systems and 20 percent larger if air conditioning is installed. Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14 3-90-08121i...
  • Page 24: Adding Air Condition

    SPLICE WILL NEED TO BE SPLIT TO MAKE THESE NEW CONNECTIONS DO NOT DISCONNECT THIS SPLICE A WHITE SPARE IS PROVIDED FOR A TRANSFORMERHOOK-UP TO FAN MOTOR TO FAN CONTROL Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14 3-90-08121i...
  • Page 25: Fan/High Limit Control

    NOTE: If fans are used in the fuel storage area, they should be installed so as not to create negative pressure in the room where the solid-fuel-burning appliance is located. Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14 3-90-08121i...
  • Page 26: Installing Electrical Power

    Low Draft Adjustment Pot on the amount of vertical rise, it may not be possible to get a low draft reading in this range. In this case, a maximum low draft of -.55 is acceptable. The adjustment screw is through the small hole to the right Figure 5.20 of the Igniter Light. Figure 5.20. Adjusted the Low Draft to __________ -IWC. Don’t forget to turn off of “Test” mode. Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14 3-90-08121i...
  • Page 27: Reference Materials

    NOT BEEN CERTIFIED INITIALLY AS COMPLYING THIS SERVICE. wITH ANSI Z21.47/CSA 2.3 OR ITS PRECEDENTS. • DO NOT CONNECT TO ANY FURNACE THAT IS NOT EQUIPPED wITH AN AIR-CIRCULATION BLOwER. Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14 3-90-08121i...
  • Page 28: Wiring Diagram

    BLACK YEL MED HI OR MED LO RED LO MALE/FEMALE CONNECTION YELLOW SKY BLUE BLACK SKY BLUE LOW FUEL AUX. OUTPUT * 10 AMP CIRCUIT BREAKER MAIN JUNCTION BOX Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14 3-90-08121i...
  • Page 29 Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14 3-90-08121i...
  • Page 30 Harman®, a brand of Hearth & Home Technologies Inc. 352 Mountain House Road, Halifax, PA 17032 www.harmanstove.com Please contact your Harman® dealer with any questions or concerns. For the location of your nearest Harman® dealer, please visit www.harmanstove.com. Printed in U.S.A. - Copyright 2012 Harman® • PF-120 Installation Manual_R1 • 2014 -___ • 03/14 3-90-08121i...

Table of Contents