SERVICING

Only authorised service technicians should undertake any repairs or Maintenance
on this product.
A detailed drawing of the gas components in this product is shown below. Part
numbers can be used to order replacement parts, if needed.
To access these components the perforated sheet metal cylinder that surrounds
the control must be removed. This is done by removing the screws top and
bottom and the channel section pilot pipe cover.
As with all gas appliances, regular servicing will improve the trouble free
operation of this appliance. This service should cover the following
- Leak test all joints
- Check operating pressures
- Clean main and pilot orifices
- Clean main burner venturi as insects and dirt may gather there.
- Inspect flexible gas hose
- Brush any soot etc. that may have gathered on stainless steel mesh.
Please fill out the warranty card (page 9) and return it to your retailing Yunca
agent.