XC‐14A, XC‐22A, XC‐30A USER'S MANUAL           Portable Air Conditioners 
Power Cord Holder 
Figure 3 – Power Cord Holder attachment 
Rubber Stoppers 
1.  Remove the Rubber Stoppers 
from the accessory box 
2.  Place the Rubber Stoppers on 
the rear of the unit as shown in 
Figure 4 
3.  Use screws to install the 
Rubber Stoppers to the rear of 
the unit (screws inside the 
accessory box) 
 
Page 8 
Xtreme Power Conversion® (XPC) Corporation 
1.  Remove the Power Cord Holder 
 
from the accessory box 
2.  Place the Power Cord Holder on 
 
the rear of the unit as 
 
shown in Figure 3 
3.  Use screws to install the Power 
Cord Holder to the rear of the unit 
(screws inside the accessory box) 
 
 
 
 
 
Figure 4 – Rubber Stopper attachment 
XC‐14A, XC‐22A, XC‐30A USER'S MANUAL           Portable Air Conditioners 
Troubleshooting Chart 
Symptom 
Water leakage 
The unit doesn't 
work 
No cold air flows 
from the cold air 
outlet 
Water flow can be 
heard after 
compressor shuts 
off 
Alarm displays "FT" 
with less than half 
of the condensate 
 
water in the tank 
 
Xtreme Power Conversion® (XPC) Corporation                                  Page 17 
Possible Causes 
Corrective Action 

Remove blockage from drain 
hose 
High water level in 

Remove any object stuck 
condensate  tank 
underneath of the black 
panel under the water tank 

Check the utility to 

verify that power is 
Reset the circuit breaker and 
available to the unit 
restart the unit 


Verify that the power 
Connect the power cord 
cord is connected 


Ambient air cannot 
Clean air filter 

be properly cooled if 
Verify that 2 minutes have 
the filter is dirty and 
passed since the unit was 
not regularly cleaned 
turned on 


Only the fan 
The temperature of the 
operates for 2 
compressor can be higher 
minutes after the 
when the ambient 
unit has been started 
temperature is too high. The 
to protect the unit 
compressor will not work 

The ambient air 
unless the ambient air 
temperature may be 
temperature is within the 
too high 
acceptable operating range 
of the unit 
Common to hear coolant 
No cause 
flowing after unit shuts off 
Spring is possibly 
Replace the spring 
broken 
(see Maintenance section) 