XC‐14A, XC‐22A, XC‐30A USER'S MANUAL Portable Air Conditioners
Troubleshooting Chart
Symptom
Water leakage
The unit doesn't
work
No cold air flows
from the cold air
outlet
Water flow can be
heard after
compressor shuts
off
Alarm displays "FT"
with less than half
of the condensate
water in the tank
Xtreme Power Conversion® (XPC) Corporation Page 17
Possible Causes
Corrective Action
Remove blockage from drain
hose
High water level in
Remove any object stuck
condensate tank
underneath of the black
panel under the water tank
Check the utility to
verify that power is
Reset the circuit breaker and
available to the unit
restart the unit
Verify that the power
Connect the power cord
cord is connected
Ambient air cannot
Clean air filter
be properly cooled if
Verify that 2 minutes have
the filter is dirty and
passed since the unit was
not regularly cleaned
turned on
Only the fan
The temperature of the
operates for 2
compressor can be higher
minutes after the
when the ambient
unit has been started
temperature is too high. The
to protect the unit
compressor will not work
The ambient air
unless the ambient air
temperature may be
temperature is within the
too high
acceptable operating range
of the unit
Common to hear coolant
No cause
flowing after unit shuts off
Spring is possibly
Replace the spring
broken
(see Maintenance section)