Xtreme XC-14A User Manual

Xc series portable air conditioning
Hide thumbs Also See for XC-14A:

Advertisement

XC Portable Air Conditioning
XC-14A, XC-22A, XC-30A Models
User & Installation Manual
www.xpcc.com
| © 2015 Xtreme Power Conversion Corporation. All rights reserved. (Rev 1/26/15)

Advertisement

Table of Contents
loading

Summary of Contents for Xtreme XC-14A

  • Page 1 XC Portable Air Conditioning XC-14A, XC-22A, XC-30A Models User & Installation Manual www.xpcc.com | © 2015 Xtreme Power Conversion Corporation. All rights reserved. (Rev 1/26/15)
  • Page 2: Table Of Contents

    Installation Guide..................8 Moving the Unit..........................8 Plugging in the Unit.........................8 Operation.....................9 Control Panel...........................9 Maintenance....................10 Filter Cleaning..........................10 Spring Replacement........................11 Troubleshooting..................11 Alarm Codes...........................12 Troubleshooting Chart........................13 Specifications.....................14 Shipping List....................14 Options......................14 Obtaining Service..................15 Xtreme Power Conversion Limited Warranty..........16 Xtreme Power Conversion Corporation Page 2...
  • Page 3 Portable Air Conditioning Thank you for selecting this Xtreme Cooling unit. It provides you with spot cooling for large areas where cooling of an entire area is not practical or possible. Please read this manual before installing the XC-14A, XC-22A, or XC-30A as it provides important information that should be followed during installation and maintenance of the Portable Air Conditioner, allowing you to correctly set up your system for the maximum safety and performance.
  • Page 4 22. Only use the unit in the upright position on a even, flat surface. Unit must be positioned at least 24 inches (60 cm) from the nearest object in any direction. 23. Stop operation immediately if abnormal noise or odor is noticed. Contact local service center. Xtreme Power Conversion Corporation Page 4...
  • Page 5: Introduction

    Product Description Xtreme Cooling Portable Air Conditioners feature spot cooling for large areas where cooling of the entire area is not practical or possible. A dedicated spot cooling thermostat controls the unit in this application. These air condi- tioners can also be used in smaller areas for room cooling.
  • Page 6: Assembly

    XC User’s Manual Portable Air Conditioning Assembly Component Parts Front and Right Side View Rear and Left Side View Xtreme Power Conversion Corporation Page 6...
  • Page 7: Power Cord Holder

    2. Place the Rubber Stoppers on the rear of the unit as shown below 3. Use screws to install the Rubber Stoppers to the rear of the unit (screws inside the accessory box) Rubber Stopper attachment Xtreme Power Conversion Corporation Page 7...
  • Page 8: Discharge Ducts / Supply Air Duct

    If any damage or excess play is found, contact a qualified repair technician or a qualified electrician to perform replacement of repair of the power cord, plug, or prongs. WARNING! If the power cord or plug are damaged, repair should only be performed by qualified electrical person- nel. Xtreme Power Conversion Corporation Page 8...
  • Page 9: Operation

    NOTE: Make sure the AC outlet is free of dirt, dust, oil, water, or any other foreign material. The unit is equipped with an approved NEMA plug configuration (XC-14A = 5-15P; XC-22A = 6-15P; XC-30A = 6-20P). The appropriate outlet must be used for each plug type.
  • Page 10: Maintenance

    Do not use any other chemicals to clean the filter, as they will likely damage the filter. 4. Dry the filter in a shaded area before replacing it. Do not operate the unit without the filter installed and the filter guard in the closed position. Xtreme Power Conversion Corporation Page 10...
  • Page 11: Spring Replacement

    3 minutes, the unit will resume operation. If the fault persists for more than 3 minutes, the evaporator fan also stops. The fault must be rectified before the unit can resume normal operation. Xtreme Power Conversion Corporation Page 11...
  • Page 12: Alarm Codes

    Replace compressor a. Empty the water tank b. After installation of the Condensate water level water tank, press the Condensate tank is full alarm SPOT / COOL or ROOM / COOL button to resume operation Xtreme Power Conversion Corporation Page 12...
  • Page 13: Troubleshooting Chart

    No cause pressor shuts off after unit shuts off Alarm displays “FT” with less than Replace the spring (see Mainte- half of the condensate water in the Spring is possibly broken nance section) tank Xtreme Power Conversion Corporation Page 13...
  • Page 14: Specifications

    1. (1) PORTABLE COOLING UNIT 2. (1) User’s and Installation Manual 3. (1) POWER CORD HOLDER 4. (4) RUBBER STOPPERS 5. DISCHARGE / SUPPLY AIR DUCTS A. (1) XC-14A B. (2) XC-22A C. (3) XC-30A Options Ambient Air Adaptor Cooling Hose Assembly...
  • Page 15: Obtaining Service

    2. Verify there are no circuit breakers tripped. 3. Call your dealer for assistance. If you cannot reach your dealer, or if they cannot resolve the problem, call Xtreme Power Conversion Corp Technical Support at 800.582.4524. Technical support inquiries can also be made at support@xpcc.com.
  • Page 16: Xtreme Power Conversion Limited Warranty

    (excluding batteries) for a period of one year for Xtreme Cooling unit from the date of purchase. For equipment sites within the United States and Canada, this warranty covers repair or replacement, at the sole discretion of XPC Corporation. The cus- tomer is responsible for the costs of shipping the defective product to XPC Corporation.