Safety Labels And Locations - Brant Radiant Heaters HLV Series Instructions For Intallation

Gas-fired infrared vacuum system tube heater
Table of Contents

Advertisement

HLV
Series
HOT
120V
NEUTRAL
EARTH
- 120V HEATER INPUT -
F/N: LLV3EP1
1/2" Gas Connection
Refer to Installation Manual
9"-14"
23cm-36cm
Gas Supply
Left Panel
(Controls Compartment)
Right Panel
(Valve Compartment)
F/N: LLTB026
Air Metering Orifice
DO NOT REMOVE
Back Panel
HOT
120V
NEUTRAL
EARTH
- 120V HEATER INPUT -
Gas Supply
Gas Supply
9" (23cm)
9" (23cm)
Gas Supply
SERVICE ACCESS PANEL
IGNITER & FLAME SENSE COMPARTMENT
1. Turn off gas & electricity.
2. Remove cover by lifting top
cover upward and outward.
CAUTION: HOT SURFACE.
KEEP COVER IN PLACE. REMOVE FOR SERVICE ONLY.
1.0
Introduction
F/N: LLAC
TP-114
1 - 1/2"
TP-3014
Air Metering Orifice
1/2" Gas Connection
Refer to Installation Manual
Gas Supply
9"-14"
23cm-36cm
Gas Supply
Gas Supply
9" (23cm)
9" (23cm)
Gas Supply
Gas Connection Label
16" Burner Tube
7

Safety Labels and Locations

RE-VERBER-RAY LOW INTENSITY INFRARED HEATER
RADIATEUR A INFRAROUGE A FAIBLE INTENSITE
FOR INDOOR INSTALLATION ONLY. NOT FOR USE IN RESIDENTIAL DWELLING.
INSTALLATION À L'EXTÉRIEUR SEULEMENT. NE PAS INSTALLER DANS UN LOGEMENT.
MODEL /MODELE NO.
INPUT BTU/H
FOR USE WITH
125,000/95,000
HLV-40-125N
NATURAL GAS
VOLTS A.C.
MANIFOLD PRESSURE
HEATER TYPE
3.5" WC
C1
120~60Hz
VERSION
STARTING AMPS.
MIN. INLET PRESSURE
5.0" WC
4.8
10/11
RUNNING AMPS.
ORIFICE SIZE
MIN. MOUNTING ANGLE:
1.1
0 DEGREES
#3 D.M.S
FOR STAINLESS STEEL UPGRADES THE
MAX. MOUNTING ANGLE:
COMBUSTION CHAMBER:
COMBUSTION TUBE IS UPGRADED TO 409
45 DEGREES
4" BC TITANIUM
STAINLESS STEEL.
ANSI Z83.20b - 2011 CSA 2.32b - 2011 Low - Intensity Infrared Htr.
FOR INDOOR USE
ANS Z83.20b - 2011 CSA - 2011 Low - Intensity Infrared Htr.
BRANT RADIANT HEATERS LIMITED
SERIAL NO.
34 SCOTT AVE., PARIS, ONTARIO
0870 XXXX XXXX 0001
TEL: 1-519-442-7823 WWW.BRANTRADIANT.COM
Rating Plate
F/N: LLV3EP2
Orange Crescent
F/N: LLV2EP9
F/N: LLV2EP15
Combustion
Chamber
Yellow Titanium Alloy Tag
(150,000 BTU/H models and greater)
Radiant
Tube

Advertisement

Table of Contents
loading

Table of Contents