Specifications - Firegear REVOLUTION EXSS OUTDOOR SERIES Installation And Operation Instructions Manual

Revolution exss outdoor series gas log heater & vented decorative gas log hearth kit
Table of Contents

Advertisement

!!! WARNING !!!
When used without adequate combustion and ventilation air,
heater may give off excessive CARBON MONOXIDE, an
odorless, poisonous gas.
!!! WARNING !!!
Before you install this appliance, have a professional installer
audit the conditions of combustion and ventilation air.
Additional ventilation may be required in conditions of tight
construction.
FIREGEAR REVOLUTION FG-360EXSSA11
GAS LOG HEARTH KIT

SPECIFICATIONS

NATURAL GAS - RATED PRESSURE – 3.5" W.C.
MINIMUM GAS
MAXIMUM GAS
PRESSURE
PRESSURE
4.5" W.C.
10.5" W.C.
Operating Pressure of Regulator per rate – 3.5" W.C.
LIQUID PROPANE - RATED PRESSURE – 10.0" W.C.
MINIMUM GAS
MAXIMUM GAS
PRESSURE
PRESSURE
11.0" W.C.
13.0" W.C.
Operating Pressure of Regulator per rate – 10.0" W.C.
HIGH ALTITUDE DERATE
In the U.S.A., input BTU shall be de-rated 4% ( 1 orifice
size ) per 1000 ft. for altitudes above 2000 ft.. In
Canada, input BTU shall be de-rated 10% ( 2 orifice
sizes ) at altitudes from 2000 ft. to 4500 ft..
MINIMUM FIREPLACE DIMENSIONS
MINIMUM FIREPLACE DIMENSIONS
MASONRY BUILT FIREPLACES
Chimney Height minimum of 6 feet – Vented Applications
LOG
FRONT
DEPTH
SET
WIDTH IN
SIZE
INCHES
INCHES
FG-360A11
30"
36"
FG-420A11
FOR OUTDOOR USE ONLY
ORIFICE
BTU/HR
SIZE
#35
ORIFICE
BTU/HR
SIZE
#51
HEIGHT
MINIMUM
IN
IN
VENT IN
INCHES
SQ INCHES
14"
19"
25.7 sq. in.
14"
20"
33.8 sq. in.
MINIMUM FIREPLACE DIMENSIONS
MINIMUM FIREPLACE DIMENSIONS
FACTORY BUILT FIREPLACES
Chimney Height minimum of 10 feet – Vented Applications
LOG
SET
SIZE
FG-360A11
FG-420A11
CLEARANCES FOR UNVENTED APPLICATIONS
PROPER CLEARANCES FROM COMBUSTIBLE
CONSTRUCTION AND MATERIALS MUST BE MAINTAINED
FROM ALL SIDES, TOP, AND BOTTOM OF THIS
APPLIANCE.
THIS APPLIANCE SHOULD NEVER BE PLACED NEAR
INLET
ANY COMBUSTIBLE SURFACE.
31,000
THIS APPLIANCE SHOULD NEVER BE PLACED UNDER
ANY COMBUSTIBLE CONSTRUCTION OR MATERIALS.
MINIMUM DIMENSIONS – SOLID-FUEL BURNING & UL 127
FACTORY BUILT FIREPLACES ( SEE FIGURE 1 )
LOG
INLET
SET
MODEL
28,000
FG-360A11
FG-420A11
The dimensions shown and defined in the fireplace
manufacturer's instructions, are the minimum clearances that
must be maintained, when installing this appliance.
Follow these instructions to insure safe installation. Failure to
follow these instructions exactly, can create a fire hazard.
3
continued
FRONT
DEPTH
HEIGHT
WIDTH IN
IN
IN
INCHES
INCHES
INCHES
30"
14"
19"
36"
14"
20"
REAR
DEPTH
FRONT
WIDTH IN
IN
WIDTH IN
INCHES
INCHES
INCHES
A
B
C
21.5"
30"
14"
26"
36"
14"
FIGURE 1
MINIMUM
VENT IN
SQ INCHES
16.6 sq. in.
22.1 sq. in.
HEIGHT
IN
INCHES
D
19"
20"

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the REVOLUTION EXSS OUTDOOR SERIES and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

B360exssa11-nB360exssa11-pB420exssa11-nB420exssa11-p

Table of Contents