Download Print this page

Firegear REVOLUTION L-360-CD SERIES Placement Instructions

Decorative gas log
Hide thumbs Also See for REVOLUTION L-360-CD SERIES:

Advertisement

Quick Links

DECORATIVE GAS LOG
PLACEMENT INSTRUCTIONS
REVOLUTION L-360-CD & L-420-CD SERIES
If for any reason, you cannot follow these instructions, FOR
ANY REASON WHATSOEVER, just return the product to your
dealer, and the dealer will refund your money. "PLEASE" do
not use this product if you cannot follow these instructions.

GENERAL INFORMATION

BEFORE YOU BEGIN!
READ THE HEARTH KIT INSTRUCTION MANUAL,
FURNISHED WITH THE APPLIANCE.
FOLLOW ALL SAFETY AND SET UP PROCEDURES!
These instructions are intended as a general guide and do not
supersede national or local codes in any way. State or local
codes may only allow operation of this appliance in a vented
configuration. Check your state or local codes. Authorities
having jurisdiction should be consulted before installation.
!!! IMPORTANT !!!
Read these instructions carefully before installing or operating
this gas appliance. These instructions should be left with the
homeowner for future reference.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
!!! WARNING !!!
If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury
or loss of life.
ANSI Z21.11.2 – (2002) STANDARD FOR GAS-FIRED
UNVENTED ROOM HEATERS (US ONLY) & ANSI Z21.60 - (2003)
/ CGA 2.26 - (2003) STANDARD FOR DECORATIVE GAS
APPLIANCES FOR INSTALLATION IN SOLID-FUEL BURNING
FIREPLACES (US & CANADA). 15LP
15LP
!!! WARNING !!!
Failure to position the parts in accordance with all included
pictures, diagrams, and drawings, or failure to use only parts
specifically approved with this appliance may result in property
damage or personal injury. DO NOT apply any extra material
or gas logs not furnished with this appliance.
!!! WARNING !!!
The position of the gas logs is critical to the safe and clean
operation of this appliance. Sooting and other problems may
result if the gas logs are not properly, and firmly positioned on
the appliance.
!!! IMPORTANT !!!
This appliance is supplied with ten ( 10 ) decorative gas logs.
Handle all gas logs with care and, it is our recommendation
that you use gloves during the set up procedures.
1

Advertisement

loading

Summary of Contents for Firegear REVOLUTION L-360-CD SERIES

  • Page 1: General Information

    DECORATIVE GAS LOG PLACEMENT INSTRUCTIONS REVOLUTION L-360-CD & L-420-CD SERIES If for any reason, you cannot follow these instructions, FOR ANY REASON WHATSOEVER, just return the product to your dealer, and the dealer will refund your money. “PLEASE” do not use this product if you cannot follow these instructions. GENERAL INFORMATION ANSI Z21.11.2 –...
  • Page 2 L-360-CD & L-420-CD DECORATIVE GAS LOG SERIES – INDIVIDUAL LOGS LOG # IFG-2401-CD LOG # IFG-2405-CD LOG # IFG-2406-CD LOG # IFG-2402-CD OR # IFG-3002-CD LOG # IFG-2409B-CD LOG # IFG-2403-CD OR # IFG-3003-CD LOG # IFG-2409-CD LOG # IFG-2410-CD LOG # IFG-2404-CD LOG # 2411-CD OR # IFG-3011 L-360-CD &...
  • Page 3 FG-HAK DECORATIVE GAS LOG FG-LAK DECORATIVE GAS LOG ACCESSORY INDIVIDUAL ADD LOGS ACCESSORY INDIVIDUAL ADD LOGS HAK-01 LAK-01 LAK-02 HAK-02 HAK-03 LAK-03 LAK-04 HAK-04 !!!WARNING!!! FG-LAK & FG-HAK add logs, may be placed anywhere within the fireplace enclosure, EXCEPT DIRECTLY IN THE FIRE. DO NOT PLACE THE ADD LOGS DIRECTLY IN THE FIRE!
  • Page 4 PROPER INSTALLATION SEQUENCE: L-360-CD & L-420-CD Place Log # IFG-2401-CD, along the left side of the grate/burner assembly, making sure to index the bottom of the log, along the grate tine. FRONT ANGLE VIEW OVERHEAD VIEW...
  • Page 5 PROPER INSTALLATION SEQUENCE: L-360-CD & L-420-CD continued Place Log # IFG-2402-CD ( Log # IFG-3002-CD for 420 series ) along the rear of the grate/burner assembly, making sure to index the locator on Log # IFG-2401-CD, and the grate tine, on the right rear of the appliance. FRONT ANGLE VIEW OVERHEAD VIEW...
  • Page 6 PROPER INSTALLATION SEQUENCE: L-360-CD & L-420-CD continued Place Log # IFG-2404-CD on the front right side of the grate/burner assembly, making sure to index the front, right two ( 2 ) grate tines, and the valve mounting bracket. FRONT ANGLE VIEW OVERHEAD VIEW...
  • Page 7 PROPER INSTALLATION SEQUENCE: L-360-CD & L-420-CD continued Place Log # IFG-2403-CD ( Log # IFG-3003-CD for 420 series ) diagonally across the center of the set, making sure to index the locator on Log # IFG-2402-CD ( Log # IFG-3002-CD for 420 series ), and the top of the grate leg and tine on the front left of the appliance.
  • Page 8 PROPER INSTALLATION SEQUENCE: L-360-CD & L-420-CD continued Place Log # IFG-2406-CD on the top right side of Log # IFG-2402-CD ( Log # IFG-3002-CD for 420 series ) and Log # IFG- 2404-CD, making sure to index the log, to the locators on the two ( 2 ) base logs. FRONT ANGLE VIEW OVERHEAD VIEW...
  • Page 9 PROPER INSTALLATION SEQUENCE: L-360-CD & L-420-CD continued Place Log # IFG-2405-CD across the center of the set, making sure to index the locators on rear Log # IFG-2402-CD ( Log # IFG-3002-CD for 420 series ), center crossing Log # IFG-2403-CD ( Log # IFG-3003-CD for 420 series ), and the tip of the front right Log # IFG-2404-CD.
  • Page 10 PROPER INSTALLATION SEQUENCE: L-360-CD & L-420-CD continued Place Log # IFG-2409B-CD on the top left side of the set, making sure to index the far left grate tine, and the top of rear Log # IFG-2402-CD ( Log # IFG-3002-CD for 420 series ). FRONT ANGLE VIEW OVERHEAD VIEW...
  • Page 11 PROPER INSTALLATION SEQUENCE: L-360-CD & L-420-CD continued Place Log # IFG-2409-CD along the front, lower, left side of the grate/burner assembly, making sure to index the rear of the log, to the front, left corner of the grate/burner assembly. FRONT ANGLE VIEW OVERHEAD VIEW...
  • Page 12 PROPER INSTALLATION SEQUENCE: L-360-CD & L-420-CD continued Place Log # IFG-2410-CD along the front, lower, right side of the grate/burner assembly, making sure to index the rear of the log, to the front, right corner of the grate/burner assembly. FRONT ANGLE VIEW OVERHEAD VIEW...
  • Page 13 PROPER INSTALLATION SEQUENCE: L-360-CD & L-420-CD continued Place Log # IFG-2411-CD (Log # IFG-3011 on 420 Series) on the bottom, center of the grate/burner assembly, making sure to index the grate tine, and the locator on the bottom of the log, to the metal tab, mounted to the bottom, front lip of the grate/burner assembly, behind Log # IFG-2410-CD.
  • Page 14 Part Number DO NOT order bolts, screws, washers or nuts. These are standard hardware items that may be purchased at any local hardware store. Shipments are contingent upon strikes, fires, and any circumstance, beyond the control of firegear. firegear, Attention: Customer Service Department 38236 Abruzzi Dr.
  • Page 15: Limited Warranty

    Refractory Gas Logs 5 years firegear is not liable for any special, indirect or consequential damages. firegear’s liability is limited to Revolution Burner 2 years the purchase price of this firegear Decorative Gas Log Set.
  • Page 16 www.firegearusa.com L360CD420CD – 4.0...

This manual is also suitable for:

Revolution l-420-cd series