GENERAL INFORMATION
These instructions are intended as a general guide and do not
supersede national or local codes in any way. State or local
codes may only allow operation of this appliance in a vented
configuration. Check your state or local codes. Authorities
having jurisdiction should be consulted before installation.
!!! IMPORTANT !!!
Read these instructions carefully before installing or operating
this gas appliance. These instructions should be left with the
homeowner for future reference.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
!!! WARNING !!!
If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury
or loss of life.
Listed below are the Canadian Standards Association (CSA)
certification numbers for the gas and ignition systems used with
firegear outdoor gas log systems. The valve systems are manufactured
by Skytech II, Inc. The complete systems are not certified as a whole
due to the lack of standard for decorative outdoor gas burning
appliance; no such standard is currently available.
Valve/Ignition System
AF-1(0,1)(0,1,2,3,4)(0,1, 5)
Applicable Standards
ANSI Z21.78-2005-CSA 6.20-2205
Combination Gas Controls For Gas Appliances
ANSI Z21.78a-2007-CSA 6.20a-2007
ANSI Z21.78b-2008-CSA 6.20b-2008
3/8, 3/8

TABLE OF CONTENTS

PROVISIONS FOR COMBUSTION & AIR
PARTS LISTING
WHAT TO DO IF YOU SMELL GAS:
<
Do not try to light any appliance.
<
Do not touch any electrical switch; do not use
any phone in your building.
<
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
<
If you can not reach your gas supplier, call the
fire department.
Do not store combustible materials or use gasoline
or other flammable vapors and liquids in the vicinity
of this or any other appliance.
Installation and service must be performed by a:
Qualified technician, service agency, or the gas
supplier.
1
1
2
2
2
3
4
6
7
8
14
15
16
16
17
21
22
REVEXSS - 2.0

Advertisement

Table of Contents
loading

Summary of Contents for Firegear REVOLUTION EXSS OUTDOOR SERIES

  • Page 1: Table Of Contents

    Do not store combustible materials or use gasoline firegear outdoor gas log systems. The valve systems are manufactured by Skytech II, Inc. The complete systems are not certified as a whole...
  • Page 2: For Outdoor Use Only

    UNVENTED APPLICATIONS B420EXSSA11-P On / Off Remote Valve Liquid Propane Hearth Kit Models are to be used with the following FIREGEAR Log Sets: Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or...
  • Page 3: Specifications

    16.6 sq. in. 36" 14" 20" 22.1 sq. in. FG-420A11 FIREGEAR REVOLUTION FG-360EXSSA11 CLEARANCES FOR UNVENTED APPLICATIONS GAS LOG HEARTH KIT PROPER CLEARANCES FROM COMBUSTIBLE SPECIFICATIONS CONSTRUCTION AND MATERIALS MUST BE MAINTAINED FROM ALL SIDES, TOP, AND BOTTOM OF THIS NATURAL GAS - RATED PRESSURE –...
  • Page 4: Clearances

    SIDEWALL & CEILING CLEARANCES MANTEL CLEARANCES WITHOUT HOOD continued MANTEL WITHOUT HOOD HEAT RESISTANT MATERIAL 12” WITHOUT HOOD 28” 12” HEATER IN FIREPLACE OR FIREBOX FIGURE 2 The sides of the fireplace opening must be a minimum of six FIGURE 3 ( 6”...
  • Page 5 FLOOR CLEARANCES INSTALLATION INFORMATION UNVENTED APPLICATIONS If installing the appliance at floor level, the minimum clearance to combustible material is six ( 6” ) inches. ( SEE FIGURE 5 ) !!! WARNING !!! This appliance is for installation only in a solid-fuel burning HEATER IN masonry or UL 127 factory-built fireplace or in a listed ventless FIREPLACE...
  • Page 6: Installation

    Massachusetts, this appliance must be installed by a licensed Propane. If you have purchased an inappropriate unit for your plumber or gasfitter. application, contact your retailer, installer, or the firegear Customer Service Center. !!! WARNING !!! WARNING: This appliance is equipped for ( Natural or FOR VENTED APPLICATIONS: This appliance, must be Propane ) gas.
  • Page 7 INSTALLATION continued FIGURE 10 – REVOLUTION BURNER ASSEMBLY FRONT VIEW Shown in black steel – actual unit is constructed of 304 Stainless Steel FIGURE 11 – REVOLUTION BURNER ASSEMBLY ANGLE VIEW Shown in black steel – actual unit is constructed of 304 Stainless Steel WHEN INSTALLING THE APPLIANCE, DO NOT OBSTRUCT THE FLOW OF COMBUSTION AND VENTILATION AIR.
  • Page 8: Set-Up & Assembly

    SET UP AND ASSEMBLY !!! IMPORTANT !!! Your FIREGEAR REVOLUTION VENTED / UNVENTED GAS BEFORE YOU BEGIN – Insure that the fire box meets the LOG HEARTH KIT comes assembled, ready for the gas minimum specifications of the appliance; see the specifications connection, with the exception of ember material and log beginning on page 3 of this manual.
  • Page 9 “ FINAL SET UP “ on page 12. FOR UNITS WITH REMOTE SYSTEMS All Firegear burner systems are capable of operation with a latching solenoid, remote control system. See the instructions, packaged with the remote system that you have purchased, for detailed installation and operational characteristics.
  • Page 10 On / Off Remote Plug-In Receptacle for Solenoid Gas / Pilot Control Knob Knob Position Indicator FIGURE 14 FIGURE 16 – HAND HELD REMOTE RECEIVER – REAR VIEW CODE SWITCHES SVE-AF – OPTIONAL SAFETY VALVE KNOB EXTENSION FIGURE 17 – HAND HELD REMOTE RECEIVER - TOP VIEW IMPORTANT HAND HELD REMOTE RECEIVER TERMINAL BLOCK CONNECTIONS, FOR HAND HELD...
  • Page 11 FIGURE 20 – WALL MOUNT REMOTE RECEIVER - TOP VIEW IMPORTANT TERMINAL BLOCK CONNECTIONS, FOR WALL MOUNT TRANSMITTER, REMOTE RECEIVERS, USE THE INSIDE TERMINAL BLOCK RECEPTACLES. ( SEE FIGURE 19 & 20 ) FIGURE 19 – WALL MOUNT REMOTE RECEIVER - REAR VIEW FINAL SET UP !!! WARNING !!! Failure to position the parts in accordance with all included...
  • Page 12: Operation

    OPERATION FOR YOUR SAFETY – READ BEFORE LIGHTING FIGURE 27 – REAR VIEW - REVOLUTION 360EXSS NATURAL GAS Shown in black steel – actual unit is constructed of 304 Stainless Steel !!! WARNING !!! Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance, and replace any part of the control system and any gas control that has been under water.
  • Page 13: Lighting Instructions

    CONTROL KNOB! If gas control knob will not rotate, 12- To manually light the burner system, gently press and turn contact your installer or the firegear Service Center. the gas control knob, in a counter-clockwise direction, to ( SEE FIGURE 30 & 31 ) the “...
  • Page 14: Maintenance & Service

    See the instructions that are packaged with the remote, and/or instructions on Page 10, of this manual. Your firegear Decorative Gas Log Set should be thoroughly Before attempting to light the appliance with the remote, inspected on a regular basis, at least once a year, by a make sure that the valve control knob is in the fully “ON”...
  • Page 15 FIREGEAR REVOLUTION NATURAL GAS HEARTH KIT PARTS LIST Shown in black steel – actual unit is constructed of 304 Stainless Steel PART NUMBER ITEM DESCRIPTION VALVE OUT & IN – REGULATOR IN – NG ONLY – BRASS HEX NIPPLE – 3/8 MALE X 3/8 MALE FLARE 48-38-38FL REGULATOR OUT –...
  • Page 16 FIREGEAR REVOLUTION LIQUID PROPANE HEARTH KIT PARTS LIST Shown in black steel – actual unit is constructed of 304 Stainless Steel PART NUMBER ITEM DESCRIPTION VALVE OUT – LP ONLY - BRASS HEX NIPPLE – 3/8 MALE X 3/8 MALE FLARE 48-38-38FL REGULATOR INPUT FEED –...
  • Page 17 Part Number DO NOT order bolts, screws, washers or nuts. They are standard hardware items, and can be purchased at any local hardware store. Shipments are contingent upon strikes, fires, and any circumstance, beyond the control of firegear. firegear LLC Attention: Customer Service Department P.O.
  • Page 18: Trouble Shooting

    FIREGEAR REVOLUTION VENTED / UNVENTED GAS LOG HEARTH KIT TROUBLE SHOOTING PROBLEM OBSERVED POSSIBLE CAUSE CORRECTIVE MEASURE Gas odor during set up Gas leak See " What to do if you smell gas " page 1 Check all gas connections...
  • Page 19: Warranty

    LIMITED WARRANTY firegear burner. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation or exclusion may not apply to you.
  • Page 20: Revexss

    www.firegearusa.com REVEXSSA11 – 2.0...