Download Print this page

Faber HAAKON Assembly And Operating Instructions Manual page 14

Freestanding wood stove

Advertisement

Wood
Sample volume max.
Primary air slide
(position)
Combustion time
During low operation, the following wood amounts, combustion air
settings and combustion times apply:
Wood
Sample volume max.
Primary air slide
(position)
Combustion time
Further heating procedure/replenishment at nominal heat performance:
Possibly available damper fully
opened
Primary air closed
Open fire door
Place logs
Close fire door
The replenishment should occur
when the flames of the previous
load have gone out
Following successful wood replenishment, flames should have formed within a
max. of one minute. If this is not the case, then you should open the primary air
damper to promote flame formation. Then this should be closed again as
necessary.
Woodlogs (up to 33cm long, circum. max.
30 cm)
2 kg or 2 – 3 pieces
In the middle
approx. 1,0 h
Woodlogs (up to 30cm long, circum. max.
25 cm)
1,2 kg or 2 – 3 pieces
Left
approx. 1,0 h
Position the damper in the longitudinal
direction of the pipe
Move primary air slide across to the closed
position (according to 4.2)
Slowly, so that no smoke enters the living
area
Two to three logs with max. 2 kg in weight.
Lateral direction in the fire area. Place
wood. In only one location.
The maximum fuel load of 2 kg may not be
exceeded.
14