User/Installer Programming Sequence - Cadet 40-120 Installation And Service Manual

Table of Contents

Advertisement

11
Operating information
Installer programming sequence
60
ON/OFF
Press UP for 5 seconds to
either Turn On or Off
Base State Screen
Show Status and Temperatures
Press
ENTER
& DOWN for
5 seconds to
Enter Installer
Menu
Set Space Heat
Setpoint at MIN
Outdoor Temperature
- Press UP or
DOWN to change
Temperature
Press
ENTER
Set Space Heat
Setpoint at MAX
Outdoor Temperature
-
- Press UP or
DOWN to change
Temperature
Press
ENTER
Set Outdoor
Shutdown Temperature
- Press UP or DOWN
to Change Temperature
Press
ENTER
Set Auto Reset High
Limit Temperature
- Press UP or DOWN
to Change
Temperature
Press
ENTER
Set DHW Boiler
Setpoint
- Press UP or DOWN
to Change
Temperature
Press
ENTER
Set MAX Space Heat
Setpoint
- Press UP or DOWN
to Change
Temperature
Press
ENTER
Save New Installer
Parameters to Control
Installation & Service Manual
After Timeout