Page 1
Operating Instructions supplied with the fi replace and should be kept together. Refer to the Installation and Operating Instructions for proper gas supply, safety requirements and operating instructions. TCWS.54NG04.C1 TRANQUILITY BURNER KIT INSTRUCTIONS PART# TCWS.54NG04.C1 For TCWS Series C 181208-16 5056.4252105 TCWS.54NG04.C1...
Contents of Package 3.4 LBS SAND HARDWARE PACK EQUALIZER ROCKS 1/2 SS FLEX LINE PILOT ASSEMBLY BURNER ASSEMBLIES BURNER TRAY ASSEMBLY PEBBLE SETS TCWS.54NG04.C1 181208-16...
Page 3
(ORANGE) to the rear electrical bulk head fi tting. Connect the fl ame sensor wire to the front electrical bulk head fi tting. (Fig. #2) Fig #3 Attach both manifold brackets to the bottom of the fi rebox using four screws. (Fig. #3) TCWS.54NG04.C1 181208-16...
Page 4
(Fig. # 4) CAUTION: Ensure that all connections are gas tight. Fig #5 Tilt burner tray length-wise and insert into the fi rebox. ORANGE WIRE (Fig. #5) Fig #6 Attach pilot to burner tray. (Fig. #6) TCWS.54NG04.C1 181208-16...
Page 5
CAUTION: The burners should be tightly butted up against each other at the center to ensure correct operation. Place sand into the burner tray and brush smooth. Use caution not to get sand near the burner ports. (Fig. #9) TCWS.54NG04.C1 181208-16...
Page 7
12. Repeat the sequence of placing the rocks three more times until the burner is covered. Fig #20 14. Install front porcelain cover (wide edge Fig #23 should face the front). (Fig. #23) WIDE EDGE TO FRONT OF FIREPLACE TCWS.54NG04.C1 181208-16...
The installation is not With a 7/16” wrench loosen the pilot proper and complete head on the pilot assembly. (Fig. #27) until the operation of the converted appliance is checked as specifi ed in the manufacturer's instructions supplied with the kit. TCWS.54NG04.C1 181208-16...
Page 9
Fig #31 Replace the minimum rate screw with the one provided in the propane con- version kit supplied with this fi replace. Ensure that the screw is fully seated. (Fig. #31) TCWS.54NG04.C1 181208-16...
Page 10
Fig #35 Fig #34 of the control system. 14. Re locate the control box shield and re-attach the access panel to the side of the fi rebox with the screws previously removed. (Fig. #34 & 35) TCWS.54NG04.C1 181208-16...
The shutter may also be opened to lessen the fl ame height. Fig #39 NOTE: Proper air shutter setting is required. The fl ame should be just orange and “lazy” . It should NEVER be set to create sooting on internal parts and window glass. TCWS.54NG04.C1 181208-16...
Need help?
Do you have a question about the TCWS.54NG04.C1 and is the answer not in the manual?