Page 1
Operating Instructions supplied with the fireplace and should be kept together. Refer to the Installation and Operating Instructions for proper gas supply, safety requirements and operating instructions. TC54 COUNTRY HOME BURNER KIT TC54.NG02.C PART# TC54.NG02.C FOR TC54 010410-16 TC54.NG02.C 5056.4256.02...
Remove ceramic filler piece from center of lower burner, set aside. Place the keyhole slots in the burner over the two screws Fig. # 1b Fig. # 1a located in the firebox base.. (Fig. # 1 & 1a-b) 1b. Slide the burner back to engage the screws in the small part of the keyhole slot and tighten screws. Fig. # 1 SCREWS Fig. #2 2. Attach the manifold supply tube from the lower burner to the front bulk head fitting and tighten. (Fig. # 2) Ensure that there are no leaks. 010410-16 TC54.NG02.C...
A panel set must now be installed. See Installation and Operating Instructions manual for details. INSULATION SLEEVES Fig. #5 5. Position the grate and attach it to the floor with two screws located behind the front legs. (Fig. # 5) 6. Attach the manifold supply tube from the upper burner to the Fig. #6 rear bulk head fitting and tighten. (Fig. # 6) Ensure that there are no leaks. 010410-16 TC54.NG02.C...
Fig. #10 RED END connections to the pilot wires coming from the upper burner pilot. Attach spark electrode (RED) and sensor leads from upper burner pilot to the rear electrical bulk head. (Fig. # 9) (The spark electrode connection has a red dot above it) Slide the insulation sleeve back on to the bulkhead connections. (Fig #10) INSULATION SLEEVES 010410-16 TC54.NG02.C...
Note: Factory supplied components must be used to ensure correct input. After conversion confirm proper manifold pressure. 1. Ensure the burners, pilots and gas supply are turned off, and the Fig. #11 appliance has cooled. 2. Remove the two screws securing the manifold assembly to the lower burner, (Fig. #11) 3. Using a 1/2” wrench, undo the natural gas burner orifice, (marked Fig. #12 #28). (Fig. #12) 010410-16 TC54.NG02.C...
Page 6
(marked #43) to ensure a good seal, before screwing it into the fitting. 10. Open shutter fully. 11. Reinstall the upper burner to the grate assembly and secure in place using the screw previously removed. 010410-16 TC54.NG02.C...
Page 7
(Fig. #18 indicates NG position, Fig. #19 indicates LP position) 14. Repeat the conversion on the pilot attached to the upper burner. Fig. #19 15. Remove access panel, 10 screws, and set aside. (Fig. #20) Fig. #20 010410-16 TC54.NG02.C...
Page 8
22. A ttach the access panel to the side of the firebox with the previ- ously removed screws. (Fig. #25) Fig. #25 Note: Gasket must be installed with access panel. Fig. #24 NATURAL PROPANE 010410-16 TC54.NG02.C...
2. Thread the extension test fitting into the open test port. Fig. #27 (Fig. # 27) 3. A ttach a pressure gauge onto the fitting. 4. W hen testing is complete, shut off the gas, remove the fitting and replace the plug. Thread sealant will be required to ensure a gas tight connection. 010410-16 TC54.NG02.C...
Note: Ember material placement and amount will affect flame appearance. More ember material results in lower flame height. Add or remove as needed until desired flame affect. Do not place any ember material on the upper burner tube. Fig. #28 CERAMIC FIBRE FILLER PIECES Ember Material Placement Fig. #28a LOG GRATE GLOWING EMBERS 010410-16 TC54.NG02.C...
Position the logs exactly as indicated by the following pictures. The three main logs have holes and / or pins. Engage each pin in the corresponding holes. The four smaller logs do not have holes or pins. They rest in position. Locate as per the diagrams (Fig. # 29-35) Note: Improper placement of logs will cause sooting on internal parts and glass. The logs may need to be repositioned slightly to avoid excessive flame impingement. Fig. #30 Fig. #29 Fig. #32 Fig. #31 010410-16 TC54.NG02.C...
1. Open and remove window frame and set aside. See "Window Frame Removal" section found in the Installation and Operating Instructions manual. 2. Remove the logs and set aside. 3. Loosen the screw in the Primary Air Shutter. 4. Rotate the shutter to increase or decrease the amount of primary air. PRIMARY AIR SHUTTERS The flame should be just orange and “lazy” . It should NEVER be set to create soot on internal parts and glass. Fig. #36 010410-16 TC54.NG02.C...
RIGHT, #3 (shown in fig.#35) ................ 5098.74615.3 BOTTOM LEFT, #4 (shown in fig.#35) ............5098.74615.4 BOTTOM RIGHT, #5 (shown in fig.#35) ............5098.74615.5 BOTTOM CENTRE, #6 (shown in fig.#35) ............ 5098.74615.6 MIDDLE, #7 (shown in fig.#35) ..............5098.74615.7 Sold only in sets 010410-16 TC54.NG02.C...
Need help?
Do you have a question about the TC54.NG02.C and is the answer not in the manual?
Questions and answers