Page 1
Operating Instructions supplied with the fi replace and should be kept together. Refer to the Installation and Operating Instructions for proper gas supply, safety requirements and operating instructions. TCWS.54NG03.C BLACK DIAMOND BURNER KIT INSTRUCTIONS PART# TCWS.54NG03.C For TCWS Series C 181208-12 5056.4252103 TCWS.54NG03.C...
(Fig. #1) Connect spark electrode wire (ORANGE) to the rear electrical bulk head fi tting. Connect the fl ame sensor wire to the front electrical bulk head fi tting. (Fig. #1) TCWS.54NG03.C 181208-12...
Page 3
Fig #2 Attach both manifold brackets to the bottom of the fi rebox using four screws. (Fig. #2) Connect gas lines to both orifice Fig #3 assemblies on the mounting brackets. (Fig. #3) CAUTION: Ensure that all connections are gas tight.
Page 4
NOTE: Too much glass media will cause sooting and improper fl ame pattern. Fig #9 10. Place rear porcelain trim, wide edge, against the back panel and press down over the pre-bent tabs on the burner tray. (Fig. #9) TCWS.54NG03.C 181208-12...
Page 5
Fig #10 11. Place the front porcelain trim so that it rests on the front shelf of the fi rebox and is snug against the fi rebox frame. Ensure that the wide edge of the trim is against the fi rebox frame. (Fig.
13/64” checked as specifi ed in the (0.2”) and re-tighten. Repeat on other manufacturer's instructions burner. (Fig. #15a) supplied with the kit. Fig #16 With a 7/16” wrench loosen the pilot head on the pilot assembly. (Fig. #16) TCWS.54NG03.C 181208-12...
Page 7
5. Slide the pilot adjustment band over and Fig #17a Fig #17b ensure that the hole in the orifi ce band is showing. Fig. #17a shows NG position Fig. #17b shows LP position). Remove the access panel, 10 screws, and set aside. NG POSITION LP POSITION Fig #18...
Page 8
Pg. 2. or servicing has been completed. Failure to do so will cause overheat Fig #24 ing and premature failure of the control system. TCWS.54NG03.C 181208-12...
Gas Pressure Check Note: To test the gas pressure, turn off the gas supply before removing the plug from Fig #27 the supply pressure test port or manifold pressure test port. Verify gas pressures with the fi replace lit and on the highest setting. SUPPLY PRESSURE MANIFOLD...
The fl ame should be just orange and “lazy” . It should NEVER be set to create sooting on internal parts and window glass. Allow the fi replace to run for 30 minutes before evaluating fl ame appearance. TCWS.54NG03.C 181208-12...
Need help?
Do you have a question about the TCWS.54NG03.C and is the answer not in the manual?
Questions and answers