The primary intention of this Service Manual is to enhance the reader's knowledge of the structures of the T10 and T20 treadmills. Notice that in case of a fault or a malfunction, the component or unit of components in question, and especially the electronic components, are not to be repaired, instead they must be replaced with a new component.
SERVICE MANUAL VERSION 1.00 2 ELECTRONICS The main electrical components of the Tunturi T10 and T20 are user interface (B02), power board (B44), motor (B18), lift motor (B25) speed sensor (B23), and power cable (B29). B15 (included in B09) FERRITE RING...
SERVICE MANUAL VERSION 1.00 5. Press ‘ENTER’ to enter KM/MILE switch mode, 1 for KM, 0 for MILE Switch between the KM or MILE setting by pressing SPEED +/- or ELEVATION +/- 6. Press ‘ENTER’ to show total distance 7. Press ‘ENTER’ to show total usage hours 8.
Page 6
SERVICE MANUAL VERSION 1.00 7. Tighten the screws (A) and verify correct elevation by measuring (Figure 3) Figure 2 Adjusting lift motor to 0% position Figure 3 Measuring correct lift motor positions Lift motor calibration is needed if any of the following has taken place: The lift motor has been removed from the frame The actual and the displayed elevation angle doesn't match - 5 -...
Page 7
SERVICE MANUAL VERSION 1.00 Table 1 Lift motor potentiometer value table for the Tunturi T10, T20, T30 & T40 Elevation Lift motor I/O 90 ± 30 (1,1 ± 0,1 k ) 170 ± 30 240 ± 30 320 ± 30 400 ±...
SERVICE MANUAL VERSION 1.00 3 ERROR TEXTS To facilitate the maintenance, error codes on display refer to internally found malfunctions; error codes as such aren't malfunctions, they merely point to observed problem. As a general rule, when a source of malfunction is located, it should not be repaired, but instead replaced with a new component.
Page 9
SERVICE MANUAL VERSION 1.00 Instruction in the owner's manual: " Lift motor error. Unplug the electrical cord from the wall outlet and from the treadmill, wait 1 minute and turn the power switch on again. If treadmill recovers to normal operation, you may continue to use the treadmill.
VERSION 1.00 Motor..........2.0 HP The T10, T20, T30 & T40 treadmill meets the requirements of the EU’s EMC Directives on electromagnetic compatibility (89/336/EEC) and electrical equipment designed for use within certain voltage limits (73/23/EEC). This product therefore carries the CE label.
Page 14
Version 14.09-05 Please note: revised parts are in bold T10 (441000) Item Part No Description Unit Item Part No Description Unit A01 103 4080 Console base B41 533 4132 Front support end cap A02 203 4077 Horizontal bar (incl. B08)