INSTALLATION AND OPERATION MANUAL
Free-Standing

EPA Certified

Wood-Burning Stoves
Save These Instructions
For Future Reference
P/N 900112-00, Rev. NC, 12/2013
P900112-00
A French manual is available upon request. Order P/N 900111-00.
Ce manuel d'installation est disponible en francais, simplement en faire la demande. Numéro de la
pièce 900111-00.
4002589
• Hot! Do not touch! The glass and surfaces of this appliance will
• Carefully supervise children in the same room as appliance.
This appliance must be properly installed and operated in order to prevent the pos-
sibility of a house fire. Please read this entire installation and operation manual
before installing and using your wood stove. Failure to follow these instruc-
tions could result in property damage, bodily injury or even death. Contact
your local building or fire officials to obtain a permit and information
on any installation requirements and inspection requirements
in your area.
be hot during operation and will retain heat for a while after
shutting off the appliance. Severe burns may result.
Wood-Burning Stoves
Models Grandview™
GV230 and GV300
With Innovative Thermal Fin Technology (TFT™)
WARNING

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Grandview GV230 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for IronStrike Grandview GV230

  • Page 1: Epa Certified

    INSTALLATION AND OPERATION MANUAL Free-Standing EPA Certified Wood-Burning Stoves Save These Instructions For Future Reference P/N 900112-00, Rev. NC, 12/2013 Wood-Burning Stoves P900112-00 Models Grandview™ GV230 and GV300 With Innovative Thermal Fin Technology (TFT™) A French manual is available upon request. Order P/N 900111-00. Ce manuel d’installation est disponible en francais, simplement en faire la demande.
  • Page 2: Table Of Contents

    CONGRATULATIONS! Pedestal Installation ..............15 Attaching Stove to Manufactured Home Floor - GV230 ....16 When you purchased your new wood stove, you joined the ranks of Outside Combustion Air Kit Installation ........17 thousands of individuals whose answer to their home heating needs Brick and Baffle Board Installation - GV230 ........
  • Page 3: Important Safety Information

    ing season to check for soot and creosote accumulations. IMPORTANT SAFETY AND WARNING Any accumulations over 1/8” thick should be removed by INFORMATION a professional chimney sweep. Do not attempt to burn out heavy creosote accumulations with a hot fire. If large ac- cumulations are occurring, review your burning procedures.
  • Page 4: Testing Information

    TESTING INFORMATION SELECTING THE PROPER VENTING SYSTEM The appliance is merely one component of a larger system. The other This manual describes the installation and operation of the Grandview™ equally important component is the venting system. This is necessary for 230 and Grandview 300 non-catalytic wood heaters.
  • Page 5: Chimney Height Requirements

    NEGATIVE PRESSURE WARNING CHIMNEY HEIGHT REqUIREMENTS This appliance is not designed to be operated in a negative pressure. The chimney must extend 3’ (.92m) above the level of roof penetration and a minimum of 2’ (.61m) higher than any roof surface within 10’ In very airtight homes with large kitchen exhaust fans, furnace cold air (3m) (see below).
  • Page 6: Clearances To Combustibles - Gv230

    Chimney and Connector CLEARANCES TO COMBUSTIBLES Minimum 6" diameter, minimum 24 MSG black steel connector pipe with UL103HT listed factory-built chimney suitable for use with solid fuels WARNING: BE ABSOLUTELY SURE THE DISTANCE BETWEEN or masonry chimney. Horizontal connection not tested, refer to local THE HEATER AND THE SURFACE OF ANY COMBUSTIBLE CON- building codes for installation.
  • Page 7 Grandview™ GV230 INSTALLATION CLEARANCES - REFER TO FIGURES 2, 3 AND 4 Alcove or Parallel Installation Corner Installation Alcove or Parallel Installation Alcove Depth 48" (1219mm) MAX. Combustible Wall Combustible Wall † Elbow Stove Floor Protection Stove Floor † † Protection Stove Floor...
  • Page 8 Grandview™ GV300 INSTALLATION CLEARANCES - REFER TO FIGURES 5, 6 AND 7 Alcove or Parallel Installation Corner Installation Alcove or Parallel Installation Alcove Depth 48" (1219mm) MAX. Combustible Wall Combustible Wall † Elbow Stove Floor Protection Stove Floor † † Protection Stove Floor...
  • Page 9: Alcove, Floor Protection - Gv230

    Grandview™ GV230 ALCOVE INSTALLATIONS - FLOOR PROTECTION When the Grandview™ 230 is installed in an Alcove, the floor protection Using the r formula: must be a thermally rated non-combustible floor protector meeting or Minimum r-value (per Inch) Specified min. exceeding a thermal rating of k=.47 or equivalent with a listed thickness thickness of of listed material thickness...
  • Page 10: Floor Protection

    Grandview™ GV300 FLOOR PROTECTION The Grandview™ 300 floor protection must be a thermally rated non- Using the r formula: combustible floor protector meeting or exceeding a thermal rating of k=.47 or equivalent with a listed thickness of 1-1/2" (38.1mm) minimum Minimum r-value (per Inch) Specified min.
  • Page 11: Specifications

    GV230 Specifications GV300 Specifications SPECIFICATIONS - GV230 AND GV300 Stove Pipe Diameter Stove Pipe Diameter Single Wall or Single Wall or Product Reference Information Double Wall 6” (152 mm) Double Wall 6” (152 mm) Cat. Description Ship. Ship. Log Length 16”...
  • Page 12: Typical Installation Figures

    Single Wall Pipe STAINLESS STEEL LINER Using 6” Diameter Single Wall Connector Pipe Using 6” Diameter Rigid Stainless Steel Liner INSTALL VENTING SYSTEM PER VENT MANUFACTURERS INSTALL VENTING SYSTEM PER VENT MANUFACTURERS INSTRUCTIONS! INSTRUCTIONS! Chimney Chimney Termination Termination Rain Cap Storm Flashing Collar...
  • Page 13: Chimney Installation

    CHIMNEY INSTALLATION Double Wall Pipe • Install chimney as per manufacturer’s instructions. Some brands of Using 6” Diameter Type L-Vent Connector Pipe pipe may require removal of the spacer ring in the flue collar. Mobile (Manufactured) Home Installation Shown • All horizontal runs of pipe should be as short as possible and are INSTALL VENTING SYSTEM PER VENT MANUFACTURERS required by NFPA No.
  • Page 14: Chimney - Wall Pass-Through Requirements

    Chimney Connector Systems and Clearances from Combustible System A Walls for Residential Heating Appliances (NFPA 211) Refer to Minimum chimney clearance to brick Figure 12. and combustibles 2 in. (51mm) System A. Minimum 3.5 in. (90 mm) thick brick masonry wall Minimum clearance 12 in.
  • Page 15: Leg Installation

    LEG INSTALLATION PEDESTAL INSTALLATION Residential and Mobile Homes Residential and Mobile Homes (Tieing down and grounding are required only in mobile homes) (Tieing down and grounding are required only in mobile homes) Open all cartons, if any and remove the contents upon receipt and check Open all cartons, if any and remove the contents upon receipt and check for any damaged or missing parts.
  • Page 16: Attaching Stove To Manufactured Home Floor - Gv230

    ATTACHING STOVE TO MANUFACTURED HOME FLOOR - Stove Back GV230 WOODSTOVE ONLY Leg Tie Down Kits (Manufactured [mobile] Homes) Order: H7665 Leg Tie Down Kit, Coastal and Lakeview Legs H5308 Leg Tie Down Kit, Olympic Legs ATTACHING STOVE TO MANUFACTURED HOME FLOOR Tie Down Holes THE STOVE MUST BE ATTACHED TO THE FLOOR AT NO LESS THAN TWO POINTS...
  • Page 17: Outside Combustion Air Kit Installation

    OUTSIDE COMBUSTION AIR KIT INSTALLATION - GV230 & GV300 Outside Air Kits Order: 1 ea. P/N UZIAD Outside Air Coupler Kit (connects outside air ducting, UZI, to stove) 1 ea. P/N UZI Outside Air Ducting Kit (includes 4” insulated flex x 10’ long) An outside air kit is required in Manufactured (mobile) Home installa- Coupler (attached to existing collar)
  • Page 18: Brick And Baffle Board Installation - Gv230

    Grandview™ GV230 BRICK AND BAFFLE INSTALLATION CAUTION: Wear gloves during brick installation in case of 1. Install firebox bottom brick spacers on both the left and right side of sharp edges inside the stove. firebox. The brick spacers are located in the package with the manual. Assure that brick spacers are pushed to each side until they are in full contact with the firebox side on each side.
  • Page 19: Brick And Baffle Board Installation - Gv300

    Grandview™ GV300 BRICK AND BAFFLE INSTALLATION CAUTION: Wear gloves during brick installation in case of 1. Install brick #1-6 in the numbered sequence shown in Figure 25. sharp edges inside the stove. 2. Install rear brick support which is included in the firebox on top of #5 and #6 brick.
  • Page 20: For Mobile Home Installs

    POST INSTALLATION CHECKS FOR MOBILE HOME INSTALLS Be sure the stove is properly grounded Check that all chimney pipe joints are secured and installed according to the Be sure the stove is properly securely manufacturers instruction. fastened to the floor If used, make sure the outside air kit is Be sure the outside air vent is free of properly installed and unobstructed.
  • Page 21: Paint Curing

    CAUTION: THE DRAFT CONTROL MUST BE FULLY OPEN BE- PAINT CURING FORE OPENING THE DOOR TO AVOID POSSIBLE COMBUSTION FLASH!! (Ignition of hot volatile gases as the door is opened). 5. Feeding excessive amounts of fuel to the stove or fireplace insert If your stove has plated accessories, be sure to clean it with a household should be avoided.
  • Page 22: Starting And Maintaining A Fire

    DO NOT LEAVE THE STOVE UNATTENDED WHILE THE FRONT STARTING AND MAINTAINING A FIRE DOOR IS SLIGHTLY OPEN. NEVER USE FLAMMABLE LIqUIDS TO START OR REKINDLE CAUTION: Do Not alter the adjustment range of the draft control for increased firing for any reason. A SOLID FUEL FIRE!! 2.
  • Page 23: Fuel

    Standard Cord of 8 Ft. Wood (2.4M) 4 Ft. (1.2M) 4 Ft. (1.2M) Figure 33 What does “Well-Seasoned” mean? When a tree is cut down, the wood is green, full of sap and moisture. This moisture content can exceed 80%, which must be reduced to less than 20%.
  • Page 24: Getting The Most Out Of Your Stove

    GETTING THE MOST OUT OF YOUR STOVE ACHIEVING CLEAN, LONG BURNS To achieve long burn times, after having thoroughly preheated the Recent developments in wood-burning technology have made wood- stove, load the firebox without blocking the small air opening found burning a cleaner and more convenient way to heat your home.
  • Page 25: Blower Operation (Optional Kit)

    BLOWER OPERATION (OPTIONAL KIT) Blower Operation The blower can be operated in either manual or automatic mode. When operated automatically, the blower will turn on when the stove is hot, and turn off when the stove is cool. MANUAL OPERATION: Flip blower mode switch to the manual position (up) and adjust blower speed dial to desired setting.
  • Page 26: Do's And Don'ts

    DO’S AND DON’TS DO NOT: Install or operate the stove or fireplace insert before reading this manual. DO NOT: Close the draft beyond the point at which the flames are completely extinguished. DO NOT: Open the stove or fireplace insert door without fully opening the draft first. DO NOT: Burn driftwood or wood that has been in salt water.
  • Page 27: Maintenance

    • Do not use abrasives such as steel pads, steel wool or oven cleaner MAINTENANCE as they will scratch the glass. Never scrape glass with a razor blade as this may pit the glass and make it impossible to clean in the future. DOOR HINGES: If door hinges need lubricating, use an anti-seize com- •...
  • Page 28: Troubleshooting

    TROUBLESHOOTING Problem Solution POOR DRAFT: Extend chimney in length or have the chimney realigned to the proper size flue. Oversized chimneys normally have poor drafts. Remember, the stove or fireplace inserts’ draft depends solely on the natural draft of the chimney (See Draft Requirements on Page 4).
  • Page 29: Replacement Parts Lists

    REPLACEMENT PARTS - MODELS GRANDVIEW™ 230 AND 300 BLOWER PARTS Item # Description GV230 GV300 Blower Snap Switch H8374 Contact an IHP dealer to obtain any of these parts. Never use Blower Blade H8375 substitute materials. Use of non-approved parts can result in poor performance and safety hazards.
  • Page 30 REPLACEMENT PARTS - MODELS GRANDVIEW™ 230 AND 300 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 31: Accessories

    ACCESSORIES - MODELS GRANDVIEW™ 230 AND 300 DOOR TRIM Item # Model Description GV230 GV300 DRTRM-GV230-NKL Door Trim, Nickel H8346 PEDESTAL (REqUIRED) DRTRM-GV230-BRNKL Door Trim, Brushed Nickel H8347 Item # Model Description GV230 GV300 BLOWER PED-GV Pedestal, Black H8343 BLWR-GV-700-SS Blower H8350 OR LEGS (REqUIRED)
  • Page 32 NOTES...
  • Page 33: Warranty

    THE WARRANTY Innovative Hearth Products ("IHP") Limited Lifetime Warranty warrants your IronStrike™ Brand Wood Burning Stove or Insert ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body, firebox and ceramic glass carry the Limited Lifetime Warranty. Ceramic glass carries the Limited Lifetime Warranty against thermal breakage only.