Summary of Contents for IronStrike Grandview GV230GL
Page 1
INSTALLATION AND OPERATION MANUAL Free-Standing EPA Certified Wood-Burning Stoves Save These Instructions For Future Reference P/N 900936-00, Rev. NC, 03/2019 Wood-Burning Stoves Model Grandview™ P900936-00 GV230GL With Innovative Thermal Fin Technology (TFT™) A French manual is available upon request. Order P/N 900936-01. Ce manuel d’installation est disponible en francais, simplement en faire la demande.
CONGRATULATIONS! Outside Combustion Air Kit Installation ........15 Brick and Baffle Board Installation - GV230GL ......16 When you purchased your new wood stove, you joined the ranks of For Mobile Home Installs ............. 18 thousands of individuals whose answer to their home heating needs Post Installation Checks ...............
ing season to check for soot and creosote accumulations. IMPORTANT SAFETY AND WARNING Any accumulations over 1/8” thick should be removed by INFORMATION a professional chimney sweep. Do not attempt to burn out heavy creosote accumulations with a hot fire. If large ac - cumulations are occurring, review your burning procedures.
28. This wood heater has a manufacturer-set minimum low 1. A chimney too large for your appliance. burn rate that must not be altered. It is against federal 2. A chimney with not enough height to produce adequate draft. regulations to alter this setting or otherwise operate this 3.
NEGATIVE PRESSURE WARNING CHIMNEY HEIGHT REQUIREMENTS This appliance is not designed to be operated in a negative pressure. The chimney must extend 3’ (.92m) above the level of roof penetration and a minimum of 2’ (.61m) higher than any roof surface within 10’ In very airtight homes with large kitchen exhaust fans, furnace cold air (3m) (see below).
Chimney and Connector CLEARANCES TO COMBUSTIBLES Minimum 6" diameter, minimum 24 MSG black steel connector pipe with UL103HT listed factory-built chimney suitable for use with solid fuels WARNING: BE ABSOLUTELY SURE THE DISTANCE BETWEEN or masonry chimney. Horizontal connection not tested, refer to local THE HEATER AND THE SURFACE OF ANY COMBUSTIBLE CON- building codes for installation.
Grandview™ GV230GL ALCOVE INSTALLATIONS - FLOOR PROTECTION Using the r formula: When the Grandview™ 230 is installed in an Alcove, the floor protection must be a thermally rated non-combustible floor protector meeting or Minimum r-value (per Inch) Specified min. exceeding a thermal rating of k=.47 or equivalent with a listed thickness thickness of of listed material thickness...
SPECIFICATIONS - GV230GL GV230GL Specifications Stove Pipe Diameter Single Wall or Double Wall 6” (152 mm) Log Length 16” W x 18” D Max. (406mm W x 457mm D Max.) 6” Firebox 17” W x 19” D x 12-1/2” H Max. (152mm) (432mm W x 483mm D x 318mm H Max.)
Single Wall Pipe STAINLESS STEEL LINER Using 6” Diameter Single Wall Connector Pipe Using 6” Diameter Rigid Stainless Steel Liner INSTALL VENTING SYSTEM PER VENT MANUFACTURERS INSTALL VENTING SYSTEM PER VENT MANUFACTURERS INSTRUCTIONS! INSTRUCTIONS! Chimney Chimney Termination Termination Rain Cap Storm Flashing Collar...
CHIMNEY INSTALLATION Double Wall Pipe • Install chimney as per manufacturer’s instructions. Some brands of Using 6” Diameter Type L-Vent Connector Pipe pipe may require removal of the spacer ring in the flue collar. Mobile (Manufactured) Home Installation Shown • All horizontal runs of pipe should be as short as possible and are INSTALL VENTING SYSTEM PER VENT MANUFACTURERS required by NFPA No.
Chimney Connector Systems and Clearances from Combustible System A Walls for Residential Heating Appliances (NFPA 211) Refer to Minimum chimney clearance to brick Figure 12. and combustibles 2 in. (51mm) System A. Minimum 3.5 in. (90 mm) thick brick masonry wall Minimum clearance 12 in.
LEG INSTALLATION PEDESTAL INSTALLATION Residential and Mobile Homes Residential and Mobile Homes (Tieing down and grounding are required only in mobile homes) (Tieing down and grounding are required only in mobile homes) Open all cartons, if any and remove the contents upon receipt and check Open all cartons, if any and remove the contents upon receipt and check for any damaged or missing parts.
ATTACHING STOVE TO MANUFACTURED HOME FLOOR - Stove Back GV230GL WOODSTOVE ONLY Leg Tie Down Kits (Manufactured [mobile] Homes) Order: H7665 Leg Tie Down Kit, Coastal and Lakeview Legs H5308 Leg Tie Down Kit, Olympic Legs ATTACHING STOVE TO MANUFACTURED HOME FLOOR Tie Down Holes THE STOVE MUST BE ATTACHED TO THE FLOOR AT NO LESS THAN TWO POINTS...
OUTSIDE COMBUSTION AIR KIT INSTALLATION - GV230GL Outside Air Kits Order: 1 ea. P/N UZIAD Outside Air Coupler Kit (connects outside air ducting, UZI, to stove) 1 ea. P/N UZI Outside Air Ducting Kit (includes 4” insulated flex x 10’ long) Coupler (attached to existing collar) An outside air kit is required in Manufactured (mobile) Home installa-...
Grandview™ GV230GL BRICK AND BAFFLE INSTALLATION CAUTION: Wear gloves during brick installation in case of 1. Install brick #1-20 in the numbered sequence shown in Figure 22. sharp edges inside the stove. 2. Brick’s 13 and 14 will be located between the steel firebox and rear baffle board (already installed).
Page 17
SECONDARY TUBE AND BAFFLE BOARD REPLACEMENT • Gently lift front baffle board upward and place on rear baffle board. See Detail A SEE DETAIL A • Starting front to rear, locate secondary tube retaining pin and rotate RETAINING PIN NOTCHES counter clockwise;...
TIMER REPLACEMENT: • Turn damper lever counter clockwise and remove from stove • Remove thermostat bracket (if equipped) by removing the two mount- UPPER PICTURE ing screws and sliding rearward through the opening; set aside ON FIGURE 27 • Loosen the top and bottom left heat shield mounting screws, leaving loose but in place;...
CAUTION: THE DRAFT CONTROL MUST BE FULLY OPEN BE- PAINT CURING FORE OPENING THE DOOR TO AVOID POSSIBLE COMBUSTION FLASH!! (Ignition of hot volatile gases as the door is opened). 5. Feeding excessive amounts of fuel to the appliance should be avoided. If your stove has plated accessories, be sure to clean it with a household It is important to supply it with sufficient draft and fuel to maintain type glass cleaner and a very soft cloth to remove any fingerprints and...
DO NOT LEAVE THE STOVE UNATTENDED WHILE THE FRONT STARTING AND MAINTAINING A FIRE DOOR IS SLIGHTLY OPEN. NEVER USE FLAMMABLE LIQUIDS TO START OR REKINDLE CAUTION: Do Not alter the adjustment range of the draft control for increased firing for any reason. A SOLID FUEL FIRE!! 2.
What does “Well-Seasoned” mean? When a tree is cut down, the wood is green, full of sap and moisture. This moisture content can exceed 80%, which must be reduced to less than 20%. Wood properly seasoned is then capable of generating the heat the stove was designed to provide.
GETTING THE MOST OUT OF YOUR STOVE ACHIEVING CLEAN, LONG BURNS To achieve long burn times, after having thoroughly preheated the Recent developments in wood-burning technology have made wood- stove, load the firebox without blocking the small air opening found burning a cleaner and more convenient way to heat your home.
BLOWER OPERATION (OPTIONAL KIT) Blower Operation The blower can be operated in either manual or automatic mode. When operated automatically, the blower will turn on when the stove is hot, and turn off when the stove is cool. MANUAL OPERATION: Flip blower mode switch to the manual position (up) and adjust blower speed dial to desired setting.
Page 24
GLASS CLEANING GUIDELINES MAINTENANCE WARNING: DO NOT CLEAN GLASS WHEN APPLIANCE IS HOT! Glass on any wood stove will not stay perfectly clean. Here are some guidelines for cleaning and caring for the glass: GLASS REPLACEMENT INSTRUCTIONS • Ensure the stove is cold prior to cleaning glass. (Refer to Figure 36) •...
DOOR GASKET: Periodically check gasket to make sure it is not over- MAINTENANCE compressed. If compressed, replace with a special woven door rope. (Don’t try substituting rope, only use IHP door rope). Have your product inspected at least once a year by a qualified PLATED ACCESSORIES: Clean only with household type glass cleaner service technician to ensure gaskets, air tubes, baffles, and and a very soft cotton cloth.
• Salt water driftwood or other previously salt water saturated mate- rials; gasket from adhering to the curing paint. • Unseasoned wood; Enjoy the warm feeling of your new IronStrike stove. ® • Christmas tree branches; • Paper products, colored paper, cardboard, plywood, or particle- board;...
TROUBLESHOOTING Problem Solution POOR DRAFT: Extend chimney in length or have the chimney realigned to the proper size flue. Oversized chimneys normally have poor drafts. Remember, the appliances’ draft depends solely on the natural draft of the chimney (See Draft Requirements on Page 4).
REPLACEMENT PARTS - MODEL GRANDVIEW™ 230GL BLOWER PARTS Item # Description GV230GL Blower Snap Switch H8374 Contact an IHP dealer to obtain any of these parts. Never use Blower Blade H8375 substitute materials. Use of non-approved parts can result in poor performance and safety hazards.
Page 29
REPLACEMENT PARTS - MODELS GRANDVIEW™ 230GL NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
ACCESSORIES - MODEL GRANDVIEW™ 230GL DOOR TRIM Item # Model Description GV230GL PEDESTAL (REQUIRED) DRTRM-GV230-NKL Door Trim, Nickel H8346 Item # Model Description GV230GL DRTRM-GV230-BRNKL Door Trim, Brushed Nickel H8347 PED-GV-GL GV GL Pedestal, Black F4033 BLOWER OR LEGS (REQUIRED) BLWR-GV-700-SS Blower H8350...
SAFETY / LISTING CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA. ROOM HEATER, SOLID FUEL TYPE, ALSO FOR USE IN MOBILE HOMES PURSUANT TO (UM) 84-HUD. LABEL - MODEL COMMUNIQUEZ AVEC LES AUTORITÉS LOCALES EN BÂTIMENT OU LE SERVICE DE PRÉVENTION DES INCENDIES GV230GL POUR CONNAÎTRE LES NORMES D'INSTALLATION ET D'INSPECTION DE VOTRE RÉGION.
IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the IHP Warranty Department at 1769 East Lawrence Street; Russellville, AL 35654 or visit our website at WWW.IRONSTRIKE.US.COM.
If you did not purchase your appliance directly from an When ordering repair parts, always give the following information: IHP dealer, then contact us at IronStrike.us.com to find your nearest IHP dealer who will answer your questions or address your concerns.
Need help?
Do you have a question about the Grandview GV230GL and is the answer not in the manual?
Questions and answers