Page 1
EPA Certified Wood-Burning Stoves Save These Instructions For Future Reference P/N 900981-00, Rev. NC, 08/2019 Performer S210AGL P900981-00 Wood Stoves Models Performer™ S210GL A French manual is available upon request. Order P/N 900981-01. Ce manuel d’installation est disponible en francais, simplement en faire la demande. Numéro de la pièce 900981-01.
CONGRATULATIONS! Manufactured (mobile) Home Installations ........10 Chimney - Wall Pass-Through Requirements ......11 When you purchased your new wood stove, you joined the ranks of Leg and Heatshield Installation ............ 12 thousands of individuals whose answer to their home heating needs Outside Air Kit Installation ............
ing season to check for soot and creosote accumulations. IMPORTANT SAFETY AND WARNING Any accumulations over 1/8” thick should be removed by INFORMATION a professional chimney sweep. Do not attempt to burn out heavy creosote accumulations with a hot fire. If large ac - READ THIS MANUAL IN ITS ENTIRETY AND UNDER- cumulations are occurring, review your burning procedures.
28. This wood heater has a manufacturer-set minimum low Excessive draft may cause an uncontrollable burn or a glowing red stove or chimney part. burn rate that must not be altered. It is against federal regulations to alter this setting or otherwise operate this Overfiring Damage - If the heater or chimney connector glows, you are wood heater in a manner inconsistent with operating overfiring.
Chimney Height Requirements CREOSOTE FORMATION AND NEED FOR REMOVAL The chimney must extend 3’ (.92m) above the level of roof penetration When wood is burned slowly, it produces tar and other organic vapors, and a minimum of 2’ (.61m) higher than any roof surface within 10’ which combine with expelled moisture to form creosote.
FUEL PAINT CURING If your appliance has plated accessories, be sure to clean plated This appliance is designed to burn dry seasoned natural wood only (see surfaces with a household type glass cleaner and a very soft cloth to Page 23 for a list of prohibited fuels). Failure to burn proper fuels only remove any fingerprints and residues prior to the first fire and before will void the certification and the warranty of the appliance.
Chimney and Connector CLEARANCES TO COMBUSTIBLES Minimum 6" diameter, minimum 24 MSG black steel connector pipe with WARNING: BE ABSOLUTELY SURE THE DISTANCE BETWEEN THE UL103HT listed factory-built chimney suitable for use with solid fuels HEATER AND THE SURFACE OF ANY COMBUSTIBLE CONSTRUC- or masonry chimney.
Single Wall Pipe STAINLESS STEEL LINER Using 6” Diameter Single Wall Connector Pipe Using 6” Diameter Rigid Stainless Steel Liner INSTALL VENTING SYSTEM PER VENT MANUFACTURERS INSTALL VENTING SYSTEM PER VENT MANUFACTURERS INSTRUCTIONS! INSTRUCTIONS! Chimney Chimney Termination Termination Rain Cap Storm Flashing Collar...
CHIMNEY INSTALLATION Double Wall Pipe • Install chimney as per manufacturer’s instructions. Some brands of Using 6” Diameter Type L-Vent Connector Pipe pipe may require removal of the spacer ring in the flue collar. Mobile (Manufactured) Home Installation Shown • All horizontal runs of pipe should be as short as possible and are INSTALL VENTING SYSTEM PER VENT MANUFACTURERS required by NFPA No.
Chimney Connector Systems and Clearances from Combustible System A Walls for Residential Heating Appliances (NFPA 211) Refer to Minimum chimney clearance to brick Figure 8 and combustibles 2 in. (51mm) System A. Minimum 3.5 in. (90 mm) thick brick masonry wall Minimum clearance 12 in.
LEG AND HEATSHIELD INSTALLATION NOTE: The threaded rods used to bolt the legs to the stove are packaged with the heatshield, as a heatshield is required when a stove is installed on legs. Residential and Mobile Homes (Bolting down and grounding of stove are required only in mobile homes).
14. All horizontal runs of pipe should be as short as possible and are STOVE INSTALLATION required by NFPA No. 211 to have an upward pitch or rise in the same direction the smoke travels of no less than 1/4” to the linear foot. The connector pipe must meet minimum clearances in any direction If not previously installed, install floor protection and move the to walls or other combustible materials.
If required, install the Outside Air Kit (P/N 71112) as per the fol- PEDESTAL INSTALLATION lowing instructions. To locate the hole in the hearth for outside air mark and cut a 4” (102 mm) hole in the hearth. The hole’s (For ash drawer pedestal see instructions included with pedestal) center should be 3”...
POST INSTALLATION CHECKS BRICK INSTALLATION CAUTION: Wear gloves during brick installation in case of Check that all chimney pipe joints are securely fastened. sharp edges inside the stove. Check that the heater is securely fastened to the floor (if ap- NOTE: Installation of the baffle boards and baffle blankets are easier plicable).
Page 16
Also included with the unit are two 15” x 10” x 1” thick baffle blankets. Install each blanket above the baffle board to each side of the secondary support with the 15” side of the blanket from front to rear of the unit. Make sure that the baffle blankets are Baffle Blankets to the full rear of the unit.
OPERATING HINTS STARTING AND MAINTAINING A FIRE Be sure to clean plated accessories with a household type 1. Burn only dry, well-seasoned wood for maximum heat output. In some cleaner and a very soft cloth to remove any fingerprints and states it is illegal to burn wet wood or anything other than clean, dry residues prior to the first fire.
BLOWER OPERATION Blower Operation The blower can be operated manually or automatically (blower will turn on when the stove is hot and turn off when the stove is cool). The rocker switch on the control panel allows you to select between manual operation or automatic operation as follows (see Figure 19): MANUAL OPERATION: Turn rocker switch to the “MANU- AL”...
OPERATING TECHNIQUES AND HINTS ACHIEVING CLEAN, LONG BURNS Recent developments in wood burning technology have made wood burning To achieve long burn times, after having thoroughly preheated the a cleaner and more convenient way to heat your home. Overall efficiency appliance, let the stovetop cool down to 275 to 400 degrees (on Elites, in a wood burning appliance is a combination of combustion efficiency locate thermometer on the face of the insert just above the door).
PLATED ACCESSORIES: Clean only with household type glass cleaner MAINTENANCE and a very soft cotton cloth. Other products may damage plated finish, paint and gaskets. BAFFLE BLANKET: Your baffle blankets should be inspected during every Have your product inspected at least once a year by a qualified chimney cleaning.
Page 21
MAINTENANCE GLASS CLEANING GUIDELINES WARNING: DO NOT CLEAN GLASS WHEN APPLIANCE IS HOT! GLASS REPLACEMENT INSTRUCTIONS Glass on any wood stove or fireplace insert will not stay perfectly clean. Here are some guidelines for cleaning and caring for the glass: Step 1.
TROUBLESHOOTING Problem Solution POOR DRAFT: Extend chimney in length or have the chimney realigned to the proper size flue. Oversized chimneys normally have poor drafts. Remember, the appliances’ draft depends solely on the natural draft of the chimney (See Draft Requirements on Page 4).
Smoke Detector Recommended DO’S AND DON’TS Since there are always several potential sources of fire in any home, we recommend installing smoke detectors. If possible, install the smoke DO NOT: Install or operate the appliance before reading this manual. detector in a hallway adjacent to the room (to reduce the possibility of occasional false activation from the heat produced by these appliances).
SAFETY / LISTING LABEL - CONTACT YOUR LOCAL BUILDING OR FIRE OFFICIALS ABOUT MODEL S210AGL RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA. LISTED ROOM HEATERS, SOLID FUEL TYPE ALSO FOR USE IN MOBILE HOME INSTALLATION (USA ONLY) PURSUANT TO (UM)84-HUD Serial No./Numéro de sérle: Report Number Model...
IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the IHP Warranty Department at 1769 East Lawrence Street; Russellville, AL 35654 or visit our website at WWW.IRONSTRIKE.US.COM.
If you did not purchase your appliance directly from an When ordering repair parts, always give the following information: IHP dealer, then contact us at IronStrike.us.com to find your nearest IHP dealer who will answer your questions or address your concerns.