Andrews polar wind portable air conditioning operating instructions & safety guide

Advertisement

Polar Wind
Portable Air Conditioning

Operating Instructions

& Safety Guide
Click
www.andrews-sykes.com
or Call Us Free
0800 211 611
General Safety
Keep children and animals away from air conditioning units.
Never leave them alone in a room where the units in use.
This equipment should only be used by a competent person who
has read and understood these instructions.
Never operate this equipment if you are ill, feeling tired or under the
influence of alcohol or drugs.
Keep the Air Conditioning vents clear of all obstructions.
Never put anything on top of the unit or block the air outlets.
Make sure equipment is switched off and unplugged after use
Never leave switched on or unattended.
Do not use the unit where sunlight is shining directly onto it.
Check condition of equipment before use. If unit is showing signs of
damage contact your supplier immediately.
Electrical Safety
This unit requires a 230 volt electrical supply. It plugs into a standard bS1363
domestic socket.
Always inspect plugs and leads for damage before plugging into the supply -
DO NOT USE IF ANY DAMAGE IS FOUND
Ensure cables are run as not to cause a hazard.
If an extension lead is used, ensure it is of the correct standard , and fully
uncoiled when being used.
Do not lay electrical cables in wet / damp areas.
Do not move equipment whilst operating.
Do not pull equipment by its cable.
It is recommended that electrical equipment is used via a suitable RCD.
Maintenance
Disconnect from the electrical supply before any cleaning or
maintenance.
DO not use chemical solvents to clean the surface of the unit. Use
a clean damp cloth.
Check the filter every week. (fig. 4).
Remove the air filter, the element may be vacuumed clean or
washed in a neutral warm water and detergent mix (40°C).
Rinse and dry the filter before replacing.
Do not dry in direct sunlight.
Laying Up
1.) Clean filter
2.) Clean surfaces
3.) Drain water from the unit
Please note water will drain from the low level water drain (Fig 5) when
the stopper is removed. Run in fan mode until the pipe is dry.
DO NOT DO THIS ON ANY INDOOR FLOOR SURFACES!
4.) When the unit is clean and drained, store in a clean, dry area. Stow cable.
The unit may be covered.
Getting started and operation
Never operate the unit in very hot or cold conditions - it works properly at
temperatures between 17 and 30º C.
Always allow the unit to stand/settle for 15 minutes before switching on when
either setting up or restarting.
Put the mobile air conditioner in a flat location where the air outlets cannot be
covered up. Place the unit no less than 50cm away from a wall or other obstacle
Fit the square end of the exhaust duct to the exhaust terminal of the unit. Fig 1.
Put the other end (discharge) to the nearest window. The length of the air
exhaust between 600mm - 1800mm. Use the min length when working.
When mounting, try to keep the air exhaust horizontal , sloping up or down.
Never operate if the hose is kinked or sagging (fig. 2 & 3).
If mounting through wall, the height of the hole should be 40cm - 130cm.

Advertisement

loading

Summary of Contents for andrews Polar Wind

  • Page 1: Operating Instructions

    General Safety Maintenance Polar Wind Keep children and animals away from air conditioning units. Disconnect from the electrical supply before any cleaning or Never leave them alone in a room where the units in use. maintenance. DO not use chemical solvents to clean the surface of the unit. Use...
  • Page 2: Continuous Drainage

    Operating Instructions - Polar Wind Dehumidifying and Cooling Operations hose. (Under this condition, attach the rubber bung to the back hole to prevent continuous drainage.) Fig. 4 The operating range for dehumidifying is 10°C-30ºC (50°F-86°F) and the Continuous Drainage operating range for cooling operating is 17°C-30°C (63°F-86°F).