General Safety

Keep children and animals away from air conditioning units.
Never leave them alone in a room where the units in use.
This equipment should only be used by a competent person who
has read and understood these instructions.
Never operate this equipment if you are ill, feeling tired or under the
influence of alcohol or drugs.
Keep the Air Conditioning vents clear of all obstructions.
Never put anything on top of the unit or block the air outlets.
Make sure equipment is switched off and unplugged after use.
Never leave switched on or unattended.
Do not use the unit where sunlight is shining directly onto it.
Check condition of equipment before use. If unit is showing signs
of damage contact your supplier immediately.

Electrical Safety

This unit requires a 230 volt electrical supply. It plugs into a standard bs1363
domestic socket.
Always inspect plugs and leads for damage before plugging into the supply -
DO NOT UsE IF ANY DAMAGE Is FOUND
Ensure cables are run as not to cause a hazard.
If an extension lead is used, ensure it is of the correct standard , and fully
uncoiled when being used.
sERIEs 2
Do not lay electrical cables in wet / damp areas.
Do not move equipment whilst operating.
Do not pull equipment by its cable.
It is recommended that electrical equipment is used via a suitable RCD.
Machine not working?
ONLY A COMPETENT ELECTRICIAN sHOULD ATTEMPT TO RECTIFY
Electrical Supply PRObLEMs. DO NOT REMOVE ANY PANELs FROM THE
MACHINE.
Problem
Likely Cause
Solution
No air flow from the
Red 'MAINs' light off
Turn on electricity and/or check mains
room unit
supply fuse
No air flow from the
Red 'MAINs' light on.
Machine is in defrost mode, do not
room unit
White 'DEFROsT'
adjust anything, machine will revert to
light on
normal run after 10 mins
Insufficient air flow
blocked air filter
Clean filter
from the room unit
No cooling
Green 'COOLING'
Revolve thermostat knob fully anti-
light off
clockwise to '1'. Wait 10 minutes for
time delay on start-up.
No cooling
Amber 'ATTENTION'
Press '+' button to re-set and check for:
light illuminated. High
Lack of water flow... kinked hoses?
pressure trip.
shortage of water..... top up.
External heat exchanger unit mounted in
very high temperature?
Water frozen? Add glycol (33%)
External heat exchanger coil blocked
with dirt.... clean
Air cooled units.... lack of air flow from
exhaust.... kinked or blocked duct, duct
too long.
No cooling
Amber 'ATTENTION'
Press '-' button to re-set and check for:
light illuminated. Low
No air flow, blocked filter?
pressure trip.
Evaporator blocked with ice. Very low air
temperature?
No cooling
Amber 'ATTENTION'
Condensate pump not reducing water
light illuminated. High
level. Kink in condensate tube between
level condensate trip.
room unit and external heat exchanger?
Leak inside room unit. Pump filter inside
room unit blocked. Condensate tube frozen

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for andrews 2 Series

  • Page 1 It is recommended that electrical equipment is used via a suitable RCD. Machine not working? ONLY A COMPETENT ELECTRICIAN sHOULD ATTEMPT TO RECTIFY ELECTRICAL sUPPLY PRObLEMs. DO NOT REMOVE ANY PANELs FROM THE MACHINE. Click www.andrews-sykes.com or Call Us Free 0800 211 611...
  • Page 2 In addition, both ends susceptible to distortion. of each pipe are fitted with ‘quick connect’ couplings that open on coupling but reseal to become water tight on disconnect. Click www.andrews-sykes.com or Call Us Free 0800 211 611...
  • Page 3 “cooling” light goes out. The room unit will now control the room temperature cooling automatically at this setting. filler cap Fig .2 Unscrew retainers and open panel. remove filter Fig .1 Click www.andrews-sykes.com or Call Us Free 0800 211 611...

This manual is also suitable for:

Pac22