Troubleshooting - Dometic RM2350 Installation And Operating Instructions Manual

Dometic refrigerator for lp-gas and electric operation
Table of Contents

Advertisement

14.
Check to make sure the slots are centred under the
flue tube and that the thermocouple is positioned
properly (tip of thermocouple extends over two
slots of burner). Note that the colour of the flame
should be clear blue over the slots of the burner.
Clear blue colour
of flame
15.
Be sure to reconnect the wire to high voltage
electrode. Check the electrode for proper location
and gap.
Electrode
Burner tube
Open the gas valve by turning knob A to
16.
17.
Check all fittings for leaks with soapy water.
18.
Connect 230-240 volt power cord to the outlet and
reconnect the 12 V DC power.
19.
Check LP gas safety shutoff.
MAINTENANCE & SERvICE
1/8" to 3/16"
(3-5 mm)
(GAS).
12

TROUBLESHOOTING

Refrigerator does not cool properly
Burner jet clogged.
Check level of refrigerator.
Venting problem.
Heavy frost buildup on evaporator fins.
Flue baffle not inserted properly in flue tube.
Improperly set thermostat.
Burner dirty.
LP gas pressure low at burner.
(Set main regulator so pressure does not drop below
2,7 kPa at pressure tap.)
Burner not located properly under flue tube.
Burner damaged.
Odour from fumes
Dislocated burner
Damaged burner
Dirty flue tube