Product Identification; Product Features; Local Codes - Vanguard FLAME-MAX Vintage Oak Log Design Series Owner's Operation And Installation Manual

18" / 24" / 30" / 36" variable manually-controlled and thermostatically controlled unvented (vent-free) propane/lp gas log heater
Hide thumbs Also See for FLAME-MAX Vintage Oak Log Design Series:
Table of Contents

Advertisement

PRODUCT
IDENTIFICATION
®
Flame-Max
Standard Oak Logs
Burner
Front Log
Piezo Ignitor
Base Assembly
Control Knob
®
Flame-Max
Golden Oak Logs
Piezo Ignitor
Burner Assembly
Control Knob
Figure 1 - Product Identification

LOCAL CODES

Install and use heater with care. Follow all
local codes. In the absence of local codes,
use the latest edition of The National Fuel
Gas Code ANSI Z223.1, also known as
NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
104343
F l a m e - M a x
Birch Logs
Crossover
Log
Back Log
Piezo Ignitor
Burner Assembly
Flame-Max
Golden Oak Logs T-Stat
One Piece
Log Set
Piezo Ignitor
Base Assembly
UNPACKING
IMPORTANT: Do not remove the metal
Data Plates from the grate assembly. The
Data Plates contain important product in-
formation.
1. Remove logs and heater base assem-
bly from carton. Note: Do not pick up
heater base assembly by the burner.
This could damage heater. Always
handle base assembly by grate.
2. Remove all protective packaging ap-
plied to logs and heater for shipment.
3.
Check all items for any shipping dam-
age. If damaged, promptly inform
dealer where you bought heater.
OWNER'S MANUAL
®
One Piece
Log Set
Control Knob
®
One Piece
Log Set
Control Knob
3
PRODUCT
FEATURES
Operation
This heater is clean burning. It requires no
outside venting. There is no heat loss out a
vent or up a chimney. Heat is generated by
realistic, dancing yellow flames. This heater
is designed for vent-free operation with flue
damper closed. State and local codes in
some areas prohibit the use of vent-free
heaters. You can operate heater as a vented
product by opening flue damper.
Safety Pilot
This heater has a pilot with an Oxygen
Depletion Sensor Shutoff System (ODS).
The ODS/pilot is a required feature for vent-
free room heaters. The ODS/pilot shuts off
the heater if there is not enough fresh air.
Piezo Ignition System
This heater has a piezo ignitor. This system
requires no matches, batteries, or other
sources to light heater.