Vanguard FLAME-MAX Vintage Oak Log Design Series Owner's Operation And Installation Manual page 10

18" / 24" / 30" / 36" variable manually-controlled and thermostatically controlled unvented (vent-free) propane/lp gas log heater
Hide thumbs Also See for FLAME-MAX Vintage Oak Log Design Series:
Table of Contents

Advertisement

VANGUARD FLAME-MAX
UNVENTED PROPANE/LP GAS LOG HEATER
INSTALLATION
Continued
INSTALLING DAMPER
CLAMP ACCESSORY FOR
VENTED OPERATION
Note: When used as a vented heater, appli-
ance must be installed only in a solid-fuel
burning fireplace with a working flue and
constructed of non combustible material.
If your heater is a manually controlled model,
you may use this heater as a vented product.
There are three reasons for operating your
heater in the vented mode:
1. The fireplace does not meet the clear-
ance to combustibles requirements for
vent-free operation
2. State or local codes do not permit vent-
free operation
3. You prefer vented operation
If reasons number 1 or 2 above apply to you,
you must permanently open chimney flue
damper. You must install the damper clamp
accessory (to order, see Accessories, page
30). This will insure vented operation (see
Figure 10). The damper clamp will keep
damper open. Installation instructions are
included with clamp accessory.
Damper
Clamp
Damper
Clamp
Damper
Masonry Fireplace
Figure 10 - Attaching Damper Clamp
See chart below for minimum permanent
flue opening you must provide. Attach
damper clamp so the minimum permanent
flue opening will be maintained at all times.
Chimney
Height (ft.) Flue Opening (sq. ins.)
6' to 15'
15' to 30'
Area of Various Standard
Diameter (ins.)
5"
6"
7"
8"
INSTALLING HEATER BASE
ASSEMBLY
WARNING: You must secure
this heater to fireplace floor. If
not, heater will move when you
adjust controls. Moving heater
may cause a gas leak.
Damper
Damper
Manufactured Fireplace
®
Minimum Permanent
39 sq. inches
29 sq. inches
Round Flues
Area (sq. ins.)
20 sq. inches
29 sq. inches
39 sq. inches
51 sq. inches
10
WARNING: If installing in a
sunken fireplace, special care is
needed. You must raise the fire-
place floor to allow access to
heater control panel. This will in-
sure adequate air flow and guard
against sooting. Raise fireplace
floor with non-combustible mate-
rial. Make sure material is secure.
CAUTION: Do not pick up
heater base assembly by the
burner. This could damage
heater. Only handle base assem-
bly by grates.
CAUTION: Do not remove the
metal data plates attached to the
heater base assembly. The data
plates contain important warranty
information.
IMPORTANT: Make sure the heater burner
is level. If heater is not level, heater will not
work properly.
104343

Advertisement

Table of Contents
loading