Alarm Codes - Xtreme XC-14A User Manual

Xc series portable air conditioning
Hide thumbs Also See for XC-14A:
Table of Contents

Advertisement

XC User's Manual

Alarm Codes

Alarm Display
Frost prevention sensor and
Abnormal temperature sen-
sor value
Refrigerant high pressure
switch
Abnormal temperature sen-
sor value
Abnormal temperature sen-
sor value
Compressor overloaded
Condensate water level
alarm
Xtreme Power Conversion Corporation
Self-Diagnostic Alarm Codes
Problem
a. Indoor heat exchanger
b. TH3 temperature sensor
a. Blocked air filter
b. Blocked / kinked exhaust
c. Ambient temperature is
TH1 temperature sensor has
a loose or broken connection
TH2 temperature sensor has
a loose or broken connection
a. Ambient temperature is
b. Unstable voltage supply
c. Defective compressor
Condensate tank is full
Cause
temperature too low
has a loose or broken
connection
duct
too high
too high
Portable Air Conditioning
Corrective Action
a. Do not use the air condi-
tioner if ambient tem-
perature is lower than
64°F (18°C)
b. Contact a qualified ser-
vice agent
a. Clean air filter
b. Ensure exhaust duct is
not blocked / kinked
c. Do not use the air condi-
tioner if ambient tem-
perature is higher than
113°F (45°C)
Contact a qualified service
agent
Contact a qualified service
agent
a. Do not use the air condi-
tioner if ambient tem-
perature is higher than
113°F (45°C)
b. Contact a qualified ser-
vice agent
c. Replace compressor
a. Empty the water tank
b. After installation of the
water tank, press the
SPOT / COOL or ROOM /
COOL button to resume
operation
Page 12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xc-22aXc-30a

Table of Contents