Spring Replacement; Troubleshooting - Xtreme XC-14A User Manual

Xc series portable air conditioning
Hide thumbs Also See for XC-14A:
Table of Contents

Advertisement

XC User's Manual
5. Replace the clean filter and close the filter guard.
6. To clean the condenser filter, lift up on the rear filter from the middle bar slightly and then angle the filter
outwards from the bottom and remove.
7. Use the same cleaning procedure as in steps 3-5 above.
8. To replace the condenser filter, place the top of the filter in the guide and slide the filter up until the bottom of
the filter clears the frame. Then push the bottom of the filter into the guide and let the filter gently fall inside
the guide.
NOTE: For effective cooling, clean the filter at least every 2 weeks.
WARNING! DO NOT operate without the filter installed.
WARNING! DO NOT operate the unit with a damaged cord or plug, after the unit malfunctions, or if the unit has
been dropped or damaged.

Spring Replacement

There are two springs on the rear of the condenser water tank guide.
1. Release the screw on the spring hook.
2. Take off the spring hook, and then pull out the opposite spring hook from the hole in the condenser water
tank guide.
3. Replace with a new spring in reverse order.
4. Repeat these steps for the other spring.

Troubleshooting

The alarm light is activated if abnormal operation occurs, and a code is displayed on the control panel. The com-
pressor and condenser fan motor will stop operating. The evaporator fan will continue to run for 3 minutes. If the
fault is rectified within 3 minutes, the unit will resume operation. If the fault persists for more than 3 minutes, the
evaporator fan also stops. The fault must be rectified before the unit can resume normal operation.
Xtreme Power Conversion Corporation
Spring Replacement
Portable Air Conditioning
Page 11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xc-22aXc-30a

Table of Contents