Panasonic CS-E7NKEW Service Manual page 14

Indoor / outdoor unit
Hide thumbs Also See for CS-E7NKEW:
Table of Contents

Advertisement

Model
Performance Test Condition
Power Supply
Capacity
Running Current
Input Power
Annual Consumption
EER
Power Factor
Indoor Noise (H / L / QLo)
Outdoor Noise (H / L)
Capacity
Running Current
Input Power
COP
Power Factor
Indoor Noise (H / L / QLo)
Outdoor Noise (H / L)
Low Temp. : Capacity (kW) / I.Power (W) / COP
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP
Max Current (A) / Max Input Power (W)
Starting Current (A)
Type
Compressor
Motor Type
Output Power
Indoor
Outdoor
Phase, Hz
V
kW
BTU/h
Kcal/h
A
W
kWh
W/W
BTU/hW
Kcal/hW
%
dB-A
Power Level dB
dB-A
Power Level dB
kW
BTU/h
Kcal/h
A
W
W/W
BTU/hW
Kcal/hW
%
dB-A
Power Level dB
dB-A
Power Level dB
W
CS-E12NKEW, CS-XE12NKEW
CU-E12NKE-3
EUROVENT
Single, 50
Min.
0.85
2900
730
-
250
-
3.40
11.60
2.92
-
42 / 28 / 20
0.85
2900
730
-
245
3.47
11.84
2.98
-
42 / 33 / 20
4.85 / 1.67k / 2.90
3.75 / 1.68k / 2.23
8.9 / 1.93k
Hermetic Motor (Rotary)
Brushless (6-poles)
14
230
Mid.
3.50
11900
3010
4.1
905
453
3.87
13.15
3.33
96
58 / -
48 / -
63 / -
4.40
15000
3780
5.1
1.09k
4.04
13.76
3.47
93
58 / -
50 / -
65 / -
5.1
700
Max.
4.00
13600
3440
-
1.18k
-
3.39
11.53
2.92
-
6.70
22800
5760
-
1.93k
3.47
11.81
2.98
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents