12.10 Indication Panel

LED
Color
Light ON
Operation ON
Light OFF
Operation OFF Timer Setting OFF
Note:
If POWER LED is blinking, the possible operation of the unit are Hot Start, during Deice operation, operation
mode judgment, or ON timer sampling.
If Timer LED is blinking, there is an abnormality operation occurs.
12.11

nanoe-G Operation

This operation provides clean air by producing great amount of negative ions and distribute through the
discharge airflow to capture or deactivate molds, bacteria or viruses.
nanoe-G operation start condition
During unit running at any operation mode, if nanoe-G operation is activated, combination operation
o
(operation mode + nanoe-G operation) starts.
During unit is OFF, if nanoe-G operation is activated, nanoe-G individual operation starts.
o

nanoe-G operation stop condition

When OFF/ON button is pressed to stop the operation.
o
When nanoe-G button is pressed.
o
When OFF Timer activates.
o

nanoe-G operation pause condition

When indoor fan stop (during deice, odor cut control, thermostat off, etc.). nanoe-G operation resume after
o
indoor fan restarts.
When indoor intake temperature ≥ 40°C. nanoe-G operation resume after indoor intake temperature ≤ 40°C
o
continuously for 30 minutes.
Indoor fan control
During any operation mode combines with nanoe-G operation, fan speed follows respective operation mode.
o
However, nanoe-G system enabled when fan speed ≥ 500rpm to ensure proper negative ion distribution,
nanoe-G system disabled when fan speed < 500 rpm.
During nanoe-G individual operation, only Auto Fan Speed and no Powerful operation is allowed. Even if Fan
o
Speed button is pressed, no signal is sent to the unit and no change on remote control display. Auto Fan
Speed for nanoe-G operation changes from SHi to Hi after 4 hours of operation.
Airflow direction control
During any operation mode combines with nanoe-G operation, airflow direction follows respective operation
o
mode.
During nanoe-G individual operation, only Auto Air Swing is allowed. Even if Air Swing button is pressed, no
o
signal is sent to the unit and no change on remote control display.
Timer control
When ON Timer activates when unit stops, previous operation resumes and restored last saved nanoe-G
o
operation status.
When ON Timer activates during any operation, no change on current operation.
o
When OFF Timer activates during any operation, all operation stops and the latest nanoe-G operation status
o
is saved.
Indicator
When nanoe-G starts, nanoe-G indicator ON.
o
POWER
TIMER
Green
Orange
Timer Setting ON
POWERFUL/QUIET
nanoe-G
Orange
Blue
POWERFUL/QUIET
nanoe-G
Mode ON
ON
POWERFUL/QUIET
nanoe-G
Mode OFF
OFF
74
ECONAVI
AUTO COMFORT
Green
Green
AUTO COMFORT
ECONAVI ON
ON
AUTO COMFORT
ECONAVI OFF
OFF

Hide quick links: