12.12.1.3
Judge Ambient Condition
According to sunlight intensity over a period of time, the system will analyze the ambient condition is sunny,
cloudy or night.
12.12.1.4
Temperature Shift
Ambient condition
Cloudy/
Night
COOL/DRY Mode
Set Temperature
HEAT Mode
Set Temperature
ECONAVI is activated while it is cloudy / night
ECONAVI is activated while it is sunny
12.12.1.5
Sunlight Sensor Check Mode
To enable sunlight sensor check mode, during unit is OFF (power standby):
Operation details
The sunlight sensor check mode will be operated for 5 minutes.
o
During check mode, the ON and OFF timer will be memorized but it operation be ignored.
o
During check mode, if the sunlight sensor check code is retransmitted, the 5 minutes counter will be reset.
o
During check mode, if sunlight sensor detected the sunlight intensity value above minimum level, the
o
ECONAVI indicator turns ON. Else if sunlight sensor detected sunlight intensity value below minimum level,
the ECONAVI indicator is OFF.
To disable sunlight sensor check mode
After check mode is ended (5 minutes counter elapsed), press AUTO OFF/ON button at indoor unit.
o
If the sunlight sensor detected sunlight intensity is at abnormal range, the check mode will be ended.
o
Please check for error code.
Sunny
Cloudy/
Night
+1°C
-1°C
Remote control normal mode
Press continuously for 15s
SET
SET
SET
SET
Sunny
-1°C
Transmit ECO demo code
and after 2 seconds return to normal
mode.
Transmit check code
and after 2 seconds return to normal
mode.
Transmit sunlight sensor check code
and after 2 seconds return to normal
mode.