12.4.1 Vertical Airflow
Operation Mode
Auto with Heat
Temperature
Heating
Cooling and Fan
Soft Dry
1. Automatic vertical airflow direction can be set using remote control; the vane swings up and down within the
angles as stated above. For heating mode operation, the angle of the vane depands on the indoor heat
exchanger temperature as Figure 1 below. It does not swing during fan motor stop. When the air conditioner is
stopped using remote control, the vane will shift to close position.
2. Manual vertical airflow direction can be set using remote control; the angles of the vane are as stated above and
the positions of the vane are as Figure 2 below. When the air conditioner is stopped using remote control, the
vane will shift to close position.
C
58°C
B
36°C
A
Indoor Heat
Exchanger Temperature
Figure 1
12.4.2
Horizontal Airflow
1. Automatic horizontal airflow direction can be set using remote control; the vane swings left and right within the
angles as stated below. For heating mode operation, the angle of the vane depends on the indoor heat
exchanger temperature as Figure 1 below. It does not swing during fan motor stop.
Heating, with heat exchanger temperature
Cooling, Fan and Soft Dry
Airflow Direction
A
Exchanger
B
C
Summer House
Manual
Auto
Manual
Auto
Manual
50°C
30°C
Operation Mode
Upper Vane Angle (°)
1
2
3
4
25
55
25
55
20
45
55
65
45 ~ 70
20
25
50
55
45 ~ 70
20
25
50
55
Closed Position
Reference point
Step 1
Step 2
Step 3
Figure 2
A
B
36
Lower Vane Angle (°)
5
1
2
3
17
37
17
37
70
17
27
37
2 ~ 39
70
2
7
17
2 ~ 39
70
2
7
17
Upper vane: 60°
Lower vane: 58°
Step 4
Step 5
Vane Angle (°)
65 ~ 115
90
65 ~ 115
4
5
47
56
27
39
27
39