Annual Start-Up And General Maintenance Schedule - Williamson-Thermoflo GWC-070 Manual

Gas-fired water boilers
Hide thumbs Also See for GWC-070:
Table of Contents

Advertisement

GWC
-
gas
fired water boiler

Annual start-up and general maintenance schedule

Service and maintenance schedules
Figure 73
Service technician
(see following pages for instructions)
General:
• Address reported problems, page 66.
• Inspect boiler area, page 66.
• Inspect boiler interior, page 66.
• Inspect condensate drain system, page 66.
• Inspect all piping for leaks, page 66.
• Inspect gas piping, page 66.
• Inspect the water system, page 66.
• Check water system chemistry, page 66
• Inspect expansion tank, page 67.
• Inspect air openings, page 67.
• Inspect vent system and air piping,
page 67.
• Inspect boiler heating surfaces, page 67.
• Inspect igniter, page 67.
• Inspect recuperator, page 68.
• Inspect temperature mixing system,
page 68.
• Inspect limit controls and cutoffs, page 68.
• Inspect gauges, page 68.
• Inspect blower motor, page 68.
• Inspect oiled-bearing circulators, page 68.
• Inspect boiler relief valve, page 69.
Additional if combustion or
performance indicates the need:
• Follow procedures under Cleaning boiler
heating surfaces, page 70 to access boiler
components listed below.
• Clean heat exchanger.
• Remove and clean burner using
compressed air only.
• Vacuum the blower.
Review:
• Review with owner.
The boiler contains ceramic fiber
and fiberglass materials. Use care
when handling these materials per
instructions on page 103 of this
manual. Failure to comply could
result in severe personal injury.
Part number 550-142-056/0411
— Boiler Manual
Owner maintenance
(see following pages for instructions)
Daily
Monthly
Periodically
Every 6 months
End of season
Follow the service and maintenance procedures given throughout
this manual and in component literature shipped with the boiler.
Failure to perform the service and maintenance could result in
damage to the boiler or system. Failure to follow the directions
in this manual and component literature could result in severe
personal injury, death or substantial property damage.
• Check boiler area
• Check air openings
• Check pressure gauge
• Check boiler interior piping
• Check venting system
• Check air vents
• Check condensate drain system
• Check relief valve
• Test low water cutoff (if used)
• Clean vent termination/air intake
screens
• Oil blower motor
• Operate relief valve
• Shut down procedure
65