Williamson-Thermoflo GWA 3 Series User's Information Manual

Gas-fired water boilers
Hide thumbs Also See for GWA 3 Series:

Advertisement

Quick Links

User's Information Manual
Hazard definitions
Hazards that will cause severe personal injury,
death or substantial property damage.
Hazards that can cause severe personal injury,
death or substantial property damage.
Hazards that will or can cause minor personal
injury or property damage.
Special instructions on installation, operation or
maintenance that are important but not related to
personal injury or property damage.
The Boiler manual is for use only by a qualified
heating installer/service technician. Refer only to
this User's Information Manual for your reference.
Improper installation, adjustment, alteration, service
or maintenance can cause property damage,
personal injury (exposure to hazardous materials)
or loss of life. Installation and service must be
performed by a qualified installer, service agency
or the gas supplier (who must read and follow the
supplied instructions before installing, servicing, or
removing this boiler. This boiler contains materials
that have been identified as carcinogenic, or
possibly carcinogenic, to humans).
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your
building.
Immediately call your gas supplier from a neighbor's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service
technician or the gas supplier.
If the information in this manual is not followed exactly, a fire or
explosion may result, causing property damage, personal injury or
loss of life.
WHAT TO DO IF YOU SMELL GAS
GWA
GWI
Gas-Fired Water Boilers
Propane gas odorant
Propane boilers only — Your propane supplier
mixes an odorant with the propane to make its pres-
ence detectable. In some instances, the odorant can
fade and the gas may no longer have an odor.
Propane gas can accumulate at floor level. Smell near the
floor for the gas odorant or any unusual odor. If you suspect
a leak, do not attempt to light the pilot.
Use caution when attempting to light the propane pilot. This
should be done by a qualified service technician, particularly
if pilot outages are common.
Periodically check the odorant level of your gas.
Inspect boiler and system at least yearly to make sure all gas
piping is leak-tight.
Consult your propane supplier regarding installation of a gas
leak detector. There are some products on the market intended
for this purpose. Your supplier may be able to suggest an
appropriate device.
INSTALLER — Please take time to review this
User's Information Manual with the boiler owner.
Explain all maintenance and service procedures
and the correct "Operating Instructions".
Series 3
Series 3
Part Number 550-142-323/0720

Advertisement

Table of Contents
loading

Summary of Contents for Williamson-Thermoflo GWA 3 Series

  • Page 1 Series 3 Series 3 Gas-Fired Water Boilers User’s Information Manual Hazard definitions Propane gas odorant Propane boilers only — Your propane supplier Hazards that will cause severe personal injury, mixes an odorant with the propane to make its pres- death or substantial property damage. ence detectable.
  • Page 2 The loss of heat can result in significant the salt residue. Therefore, Williamson-Thermoflo equipment damage due to freezing. contaminated with saltwater or polluted water will no longer be covered under warranty and should be replaced.
  • Page 3 GWA & GWI Series 3 Gas-Fired Water Boilers – User’s Information Manual Air contamination To prevent potential of severe personal injury or death, check for products or areas listed in table below before installing boiler. If any of these contaminants are found, do one of the following: •...
  • Page 4: Service Technician

    GWA & GWI Series 3 Gas-Fired Water Boilers – User’s Information Manual To locate Operating Instructions: Find your boiler model number on boiler nameplate (begins with GWA or GWI). GWA model number will include a suffix indicating pilot ignition —”I” for spark-ignited pilot. Read the valve manufacturer’s model and name on the boiler gas valve. Locate the correct “Operating Instructions”...
  • Page 5: For Your Safety Read Before Operating

    GWA & GWI Series 3 Gas-Fired Water Boilers – User’s Information Manual Operating Instructions GWA — Spark-ignited pilot Gas valve — Honeywell VR8204 or VR8304 — White-Rodgers 36C or 36E FOR YOUR SAFETY READ BEFORE OPERATING If you do not follow these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.
  • Page 6 GWA & GWI Series 3 Gas-Fired Water Boilers – User’s Information Manual Operating Instructions GWA — Spark-ignited pilot Gas valve — Robertshaw 7200 Part Number 550-142-323/0720...
  • Page 7 GWA & GWI Series 3 Gas-Fired Water Boilers – User’s Information Manual Operating instructions All gas valves FOR YOUR SAFETY READ BEFORE OPERATING If you do not follow these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life. A.
  • Page 8: Maintenance Procedures

    GWA & GWI Series 3 Gas-Fired Water Boilers – User’s Information Manual ❏ Maintenance procedures The boiler should be inspected and started annu- The following information provides detailed instruc- ally, at the beginning of the heating season, only tions for completing the maintenance items listed in by a qualified service technician.
  • Page 9 GWA & GWI Series 3 Gas-Fired Water Boilers – User’s Information Manual ❏ Check monthly ❏ Check monthly Boiler piping Automatic air vents (if used) 1. Visually inspect for leaks around piping, circulators, relief 1. Remove the cap from any automatic air valve and other fittings.
  • Page 10: Every 6 Months

    GWA & GWI Series 3 Gas-Fired Water Boilers – User’s Information Manual ❏ Check monthly ❏ Every 6 months Main burner flame Operate boiler relief valve Proper main burner flame (see below): To avoid water damage or scalding due to valve operation, a metal discharge line must be con- 1.
  • Page 11 GWA & GWI Series 3 Gas-Fired Water Boilers – User’s Information Manual ❏ Troubleshooting Troubleshooting – Common problems and possible solutions Symptom Common Causes Possible Corrections Rapid cycling — Thermostat installed where drafts Locate thermostat on inner wall away from heat sources or cool boiler turns on and or heat affect reading.
  • Page 12 GWA & GWI Series 3 Gas-Fired Water Boilers – User’s Information Manual Part Number 550-142-323/0720...

This manual is also suitable for:

Gwi 3 series