Switch For Monitoring Control Cam (S8) - Pfaff 3117 Instruction Manual

Table of Contents

Advertisement

Adjustment
14
Switch for monitoring control cam ( S8 )
.31.04
14 - 66
Requirement
In the program end position, switch 1 must be securely on. After approx. 10 mm of the
path of the work clamp, the switch 1 must be free.
2
Fig. 14 - 64
Loosen screws 2 land move switch 1 in accordance with the requirement.
Tighten screws 2.
1