Adjustment
14
Needle bar and needle
.06
14
Pre-adjusting the needle bar height
.06.01
14 - 6
Requirement
With the needle bar at its BDC, there should be a clearance of 11.5 mm between the
bottom edge of the needle bar 1 and the needle plate.
Fig. 14 - 05
Bring the needle bar to its BDC.
Loosen the screw 2 that can now be seen.
Move the needle bar 1 in accordance with the requirement.
Tighten screw 2.
2